244 MOS FET Relays G3VM-21LR11
■Absolute Maximum Ratings (Ta = 25°C)
■Electrical Characteristics (Ta = 25°C)
■Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item Symbol Rating Unit Measurement Conditions
Input LED forward current IF50 mA
LED forward current
reduction rate
Δ IF/°C−0.5 mA/°CT
a ≥ 25°C
LED reverse voltage VR5V
Connection temperature Tj125 °C
Output Load voltage (AC peak/DC) VOFF 20 V
Continuous load current
(AC peak/DC)
IO900 mA
ON current reduction rate Δ IO/°C−12 mA/°CT
a ≥ 50°C
Connection temperature Tj125 °C
Dielectric strength between input and
output (See note 1.)
VI-O 1,500 Vrms AC for 1 min
Ambient operating temperature Ta−20 to +85 °C With no icing or condensation
Storage temperature Tstg −40 to +125 °C With no icing or condensation
Soldering temperature --- 260 °C 10 s
Note: 1. The dielectric strength between the input and
output was checked by applying voltage be-
tween all pins as a group on the LED side and
all pins as a group on the light-receiving side.
Item Symbol Mini-
mum Typical Maxi-
mum Unit Measurement
conditions
Input LED forward voltage VF1.0 1.15 1.3 V IF = 10 mA
Reverse current IR--- --- 10 μAV
R = 5 V
Capacity between terminals CT--- 15 --- pF V = 0, f = 1 MHz
Trigger LED forward current IFT --- --- 3.0 mA IO = 100 mA
Output Maximum resistance with output ON RON --- 0.18 0.22 ΩIF = 5 mA,
IO = 900 mA, t < 1 s
Current leakage when the relay is open ILEAK --- 0.2 1.0 nA VOFF = 20 V
Capacity between terminals COFF --- 40 80 pF V = 0, f = 100 MHz,
t < 1 s
Capacity between I/O terminals CI-O --- 0.3 --- pF f = 1 MHz, Vs = 0 V
Insulation resistance between I/O terminals RI-O 1,000 --- --- MΩVI-O = 500 VDC,
RoH ≤ 60%
Tu r n - O N t i m e tON --- 0.3 2.0 ms IF = 5 mA, RL = 200 Ω,
VDD = 10 V (See note 2.)
Turn-OFF time tOFF --- 0.2 1.0 ms
VOUT
IF
tON tOFF
10% 90%
IF1
2
4
3
RLVDD
VOUT
Note: 2. Turn-ON and Turn-OFF
Times
Item Symbol Minimum Typical Maximum Unit
Load voltage (AC peak/DC) VDD --- --- 20 V
Operating LED forward current IF--- --- 20 mA
Continuous load current (AC peak/DC) IO--- --- 900 mA
Operating temperature Ta−20 --- 65 °C