Mixed Signal Oscilloscopes MSO4000B, DPO4000B Series Data Sheet Connectivity Two USB 2.0 Host Ports on the Front Panel and Two on the Rear Panel for Quick and Easy Data Storage, Printing, and Connecting a USB Keyboard USB 2.0 Device Port on Rear Panel for Easy Connection to a PC or Direct Printing to a PictBridge(R)-compatible Printer Integrated 10/100/1000BASE-T Ethernet Port for Network Connection and Video Out Port to Export the Oscilloscope Display to a Monitor or Projector Optional Serial Triggering and Analysis Automated Serial Triggering, Decode, and Search Options for I2C, SPI, USB, Ethernet, CAN, LIN, FlexRay, RS-232/422/485/UART, MIL-STD-1553, and I2S/LJ/RJ/TDM Features & Benefits Key Performance Specifications Mixed Signal Design and Analysis (MSO Series) Automated Triggering, Decode, and Search on Parallel Buses Per-channel Threshold Settings 1 GHz, 500 MHz, 350 MHz Bandwidth Models Multichannel Setup and Hold Triggering 4 Analog Channel Models MagniVuTM High-speed Acquisition Provides 60.6 ps Fine Timing Resolution on Digital Channels 16 Digital Channels (MSO Series) Up to 5 GS/s Sample Rate on All Channels 20 Megapoint Record Length on All Channels >50,000 wfm/s Maximum Waveform Capture Rate Standard Passive Voltage Probes with Less than 4 pF Capacitive Loading and 500 MHz or 1 GHz Analog Bandwidth Suite of Advanced Triggers Ease of Use Features Wave Inspector(R) Controls provide Easy Navigation and Automated Search of Waveform Data 41 Automated Measurements, Waveform Histograms, and FFT Analysis for Simplified Waveform Analysis TekVPI(R) Probe Interface supports Active, Differential, and Current Probes for Automatic Scaling and Units 10.4 in. (264 mm) Bright XGA Color Display Small Footprint and Lightweight - Only 5.8 in. (147 mm) deep and 11 lb. (5 kg) Optional Application Support Power Analysis Limit and Mask Testing HDTV and Custom Video Analysis Feature-rich Tools for Debugging Mixed Signal Designs With the MSO/DPO4000B Mixed Signal Oscilloscope Series, you can analyze up to 20 analog and digital signals with a single instrument to quickly find and diagnose problems in complex designs. Bandwidths up to 1 GHz and a minimum of 5X oversampling on all channels ensure you have the performance you need to see fast-changing signal details. To capture long windows of signal activity while maintaining fine timing resolution, the MSO/DPO4000B Series offers a deep record length of 20M points standard on all channels. With Wave Inspector(R) controls for rapid waveform navigation, automated serial and parallel bus analysis, limit and mask testing, and automated power analysis - the MSO/DPO4000B Oscilloscope Series from Tektronix provides the feature-rich tools you need to simplify and speed debug of your complex design. Data Sheet Discover - Fast waveform capture rate - over 50,000 wfm/s - maximizes the probability of capturing elusive glitches and other infrequent events. Comprehensive Features Speed Every Stage of Debug The MSO/DPO4000B Series offers a robust set of features to speed every stage of debugging your design - from quickly discovering an anomaly and capturing it, to searching your waveform record for the event and analyzing its characteristics and your device's behavior. Discover To debug a design problem, first you must know it exists. Every design engineer spends time looking for problems in their design, a time-consuming and frustrating task without the right debug tools. The MSO/DPO4000B Series offers the industry's most complete visualization of signals, providing fast insight into the real operation of your device. A fast waveform capture rate - greater than 50,000 waveforms per second - enables you to see glitches and other infrequent transients within seconds, revealing the true nature of device faults. A digital phosphor display with intensity grading shows the history of a signal's activity by intensifying areas of the signal that occur more frequently, providing a visual display of just how often anomalies occur. 2 www.tektronix.com Capture - Triggering on a specific transmit data packet going across an RS-232 bus. A complete set of triggers, including triggers for specific serial packet content, ensures you quickly capture your event of interest. Capture Discovering a device fault is only the first step. Next, you must capture the event of interest to identify root cause. Accurately capturing any signal of interest begins with proper probing. The MSO/DPO4000B Series includes four low-capacitance probes for accurate signal capture. These industry-first high-impedance passive voltage probes have less than 4 pF of capacitive loading to minimize the affect of the probe on your circuit's operation, offering the performance of an active probe with the flexibility of a passive probe. The MSO/DPO4000B Series provides a complete set of triggers - including runt, timeout, logic, pulse width/glitch, setup/hold violation, serial packet, and parallel data - to help quickly find your event. With up to a 20M point record length, you can capture many events of interest, even thousands of serial packets, in a single acquisition for further analysis while maintaining high resolution to zoom in on fine signal details. From triggering on specific packet content to automatic decode in multiple data formats, the MSO/DPO4000B Series provides integrated support for the industry's broadest range of serial buses - I2C, SPI, USB, Ethernet, CAN, LIN, FlexRay, RS-232/422/485/UART, MIL-STD-1553, and I2S/LJ/RJ/TDM. The ability to decode up to four serial and/or parallel buses simultaneously means you gain insight into system-level problems quickly. To further help troubleshoot system-level interactions in complex embedded systems, the MSO4000B Series offers 16 digital channels in addition to its analog channels. Since the digital channels are fully integrated into the oscilloscope, you can trigger across all input channels, automatically time correlating all analog, digital, and serial signals. The MagniVuTM high-speed acquisition enables you to acquire fine signal detail (up to 60.6 ps resolution) around the trigger point for precision measurements. MagniVu is essential for making accurate timing measurements for setup and hold, clock delay, signal skew, and glitch characterization. Mixed Signal Oscilloscopes -- MSO4000B, DPO4000B Series Search - I2C decode showing results from a Wave Inspector search for Address value 50. Wave Inspector controls provide unprecedented efficiency in viewing and navigating waveform data. Search Finding your event of interest in a long waveform record can be time consuming without the right search tools. With today's record lengths pushing beyond a million data points, locating your event can mean scrolling through thousands of screens of signal activity. The MSO/DPO4000B Series offers the industry's most comprehensive search and waveform navigation with its innovative Wave Inspector(R) controls. These controls speed panning and zooming through your record. With a unique force-feedback system, you can move from one end of your record to the other in just seconds. User marks allow you to mark any location that you may want to reference later for further investigation. Or, automatically search your record for criteria you define. Wave Inspector will instantly search your entire record, including analog, digital, and serial bus data. Along the way it will automatically mark every occurrence of your defined event so you can quickly move between events. Analyze Verifying that your prototype's performance matches simulations and meets the project's design goals requires analyzing its behavior. Tasks can range from simple checks of rise times and pulse widths to sophisticated power loss analysis and investigation of noise sources. Analyze - Waveform histogram of a falling edge showing the distribution of edge position (jitter) over time. Included are numeric measurements made on the waveform histogram data. A comprehensive set of integrated analysis tools speeds verification of your design's performance. The MSO/DPO4000B Series offers a comprehensive set of integrated analysis tools including waveform- and screen-based cursors, 41 automated measurements, advanced waveform math including arbitrary equation editing, waveform histograms, FFT analysis, and trend plots for visually determining how a measurement is changing over time. Specialized application support for serial bus analysis, power supply design, limit and mask testing, and video design and development is also available. For extended analysis, National Instrument's LabVIEW SignalExpressTM Tektronix Edition provides over 200 built-in functions including time and frequency domain analysis, data logging, and customizable reports. Mixed Domain Analysis Working with RF signals? Be sure to check out the MDO4000 Series - the world's first Mixed Domain Oscilloscope. Built on the MSO4000B oscilloscope platform, the MDO4000 Series offers a built-in spectrum analyzer (up to 6 GHz). This combination offers you the ability to capture time-correlated analog, digital, and RF signals in a single instrument. For more information on the MDO4000 Series, please visit www.tektronix.com/mdo4000. www.tektronix.com 3 Data Sheet Search step 1: You define what you would like to find. Wave Inspector controls provide unprecedented efficiency in viewing, navigating, and analyzing waveform data. Zip through your 20M point record by turning the outer pan control (1). Get from the beginning to end in seconds. See something of interest and want to see more details? Just turn the inner zoom control (2). Wave Inspector(R) Navigation and Search A 20M point record length represents thousands of screens of information. The MSO/DPO4000B Series enables you to find your event in seconds with Wave Inspector, the industry's best tool for navigation and search. Wave Inspector offers the following innovative controls: Zoom/Pan A dedicated, two-tier front-panel control provides intuitive control of both zooming and panning. The inner control adjusts the zoom factor (or zoom scale); turning it clockwise activates zoom and goes to progressively higher zoom factors, while turning it counterclockwise results in lower zoom factors and eventually turning zoom off. No longer do you need to navigate through multiple menus to adjust your zoom view. The outer control pans the zoom box across the waveform to quickly get to the portion of waveform you are interested in. The outer control also utilizes force feedback to determine how fast to pan on the waveform. The farther you turn the outer control, the faster the zoom box moves. Pan direction is changed by simply turning the control the other way. Play/Pause A dedicated Play/Pause front-panel button scrolls the waveform across the display automatically while you look for anomalies or an event of interest. Playback speed and direction are controlled using the intuitive pan control. Once again, turning the control further makes the waveform scroll faster and changing direction is as simple as turning the control the other way. 4 www.tektronix.com Search step 2: Wave Inspector automatically searches through the record and marks each event with a hollow white triangle. You can then use the Previous and Next buttons to jump from one event to the next. User Marks Press the Set Mark front-panel button to place one or more marks on the waveform. Navigating between marks is as simple as pressing the Previous () and Next () buttons on the front panel. Search Marks The Search button allows you to automatically search through your long acquisition looking for user-defined events. All occurrences of the event are highlighted with search marks and are easily navigated to, using the front-panel Previous () and Next () buttons. Search types include edge, pulse width/glitch, timeout, runt, logic, setup and hold, rise/fall time, parallel bus, and I2C, SPI, USB, Ethernet, CAN, LIN, FlexRay, RS-232/422/485/UART, MIL-STD-1553, and I2S/LJ/RJ/TDM packet content. Mixed Signal Oscilloscopes -- MSO4000B, DPO4000B Series Digital phosphor technology enables greater than 50,000 wfm/s waveform capture rate and real-time intensity grading on the MSO/DPO4000B Series. The MSO Series provides 16 integrated digital channels enabling you to view and analyze time-correlated analog and digital signals. Digital Phosphor Technology The MSO/DPO4000B Series' digital phosphor technology provides you with fast insight into the real operation of your device. Its fast waveform capture rate - greater than 50,000 wfm/s - gives you a high probability of quickly seeing the infrequent problems common in digital systems: runt pulses, glitches, timing issues, and more. Waveforms are superimposed with one another and waveform points that occur more frequently are intensified. This quickly highlights the events that over time occur more often or, in the case of infrequent anomalies, occur less often. With the MSO/DPO4000B Series, you can choose infinite persistence or variable persistence (including zero persistence), determining how long the previous waveform acquisitions stay on-screen. This allows you to determine how often an anomaly is occurring. Accurate High-speed Probing The TPP Series probes, included standard with every MSO/DPO4000B Series oscilloscope, provide up to 1 GHz of analog bandwidth, and less than 4 pF of capacitive loading. The extremely low capacitive loading minimizes adverse affects on your circuits and is more forgiving of longer ground leads. And, since the probe bandwidth matches your oscilloscope bandwidth, you can see the high-frequency components in your signal which is critical for high-speed applications. The TPP Series passive voltage probes offer all the benefits of general-purpose probes like high dynamic range, flexible connection options, and robust mechanical design, while providing the performance of active probes. Mixed Signal Design and Analysis (MSO Series) The MSO4000B Series Mixed Signal Oscilloscopes provide 16 digital channels. These channels are tightly integrated into the oscilloscope's user With the color-coded digital waveform display, groups are created by simply placing digital channels together on the screen, allowing the digital channels to be moved as a group. You can set threshold values for each channel, enabling support for up to 16 different logic families. interface, simplifying operation and making it possible to solve mixed-signal issues easily. Color-coded Digital Waveform Display The MSO4000B Series has redefined the way you view digital waveforms. One common problem shared by both logic analyzers and mixed signal oscilloscopes is determining if data is a one or a zero when zoomed in far enough that the digital trace stays flat all the way across the display. The MSO4000B Series has color-coded digital traces, displaying ones in green and zeros in blue. www.tektronix.com 5 Data Sheet White edges indicate additional information is available by zooming in. As shown here, zooming in on the white edge reveals a hidden glitch. The P6616 MSO probe offers two eight-channel pods to simplify connecting to your device. The MSO4000B Series simplifies channel setup by allowing you to group digital waveforms and enter waveform labels by using a USB keyboard. By simply placing digital waveforms next to each other, they form a group. Once a group is formed, you can position all the channels contained in that group collectively. This greatly reduces the normal setup time associated with positioning channels individually. The MagniVu high-resolution record provides 60.6 ps timing resolution, enabling you to make critical timing measurements on your digital waveforms. The multiple transition detection hardware of the MSO4000B Series will show you a white edge on the display when the system detects multiple transitions. White edges indicate that more information is available by zooming in or acquiring at faster sampling rates. In most cases zooming in will reveal the pulse that was not viewable with the previous settings. If the white edge is still present after zooming in as far as possible, this indicates that increasing the sample rate on the next acquisition will reveal higher frequency information than the previous settings could acquire. 6 www.tektronix.com MagniVuTM High-speed Acquisition The main digital acquisition mode on the MSO4000B Series will capture up to 20M points at 500 MS/s (2 ns resolution). In addition to the main record, the MSO4000B Series provides an ultra high-resolution record called MagniVu which acquires 10,000 points at up to 16.5 GS/s (60.6 ps resolution). Both main and MagniVu waveforms are acquired on every trigger and can be switched between in the display at any time, running or stopped. MagniVu provides significantly finer timing resolution than comparable MSOs on the market, instilling confidence when making critical timing measurements on digital waveforms. P6616 MSO Probe This unique probe design offers two eight-channel pods. Each channel ends with a probe tip featuring a recessed ground for simplified connection to the device under test. The coax on the first channel of each pod is colored blue making it easy to identify. The common ground uses an automotive-style connector making it easy to create custom grounds for connecting to the device under test. When connecting to square pins, the P6616 has an adapter that attaches to the probe head extending the probe ground flush with the probe tip so you can attach to a header. The P6616 offers outstanding electrical characteristics, having only 3 pF of capacitive loading, a 100 k input resistance, and capable of acquiring toggle rates >500 MHz and pulses as short as 1 ns in duration. Mixed Signal Oscilloscopes -- MSO4000B, DPO4000B Series Triggering on a specific OUT Token packet on a USB full-speed serial bus. The yellow waveform is the D+ and the blue waveform is the D-. A bus waveform provides decoded packet content including Start, Sync, PID, Address, End Point, CRC, Data values, and Stop. Serial Triggering and Analysis (Optional) On a serial bus, a single signal often includes address, control, data, and clock information. This can make isolating events of interest difficult. The MSO/DPO4000B Series offers a robust set of tools for debugging serial buses with automatic trigger, decode, and search for I2C, SPI, USB, Ethernet, CAN, LIN, FlexRay, RS-232/422/485/UART, MIL-STD-1553, and I2S/LJ/RJ/TDM. Serial Triggering Trigger on packet content such as start of packet, specific addresses, specific data content, unique identifiers, etc. on popular serial interfaces such as I2C, SPI, USB, Ethernet, CAN, LIN, FlexRay, RS-232/422/485/UART, MIL-STD-1553, and I2S/LJ/RJ/TDM. Bus Display Provides a higher-level, combined view of the individual signals (clock, data, chip enable, etc.) that make up your bus, making it easy to identify where packets begin and end and identifying subpacket components such as address, data, identifier, CRC, etc. Event table showing decoded Identifier, DLC, DATA, and CRC for every CAN packet in a long acquisition. Bus Decoding Tired of having to visually inspect the waveform to count clocks, determine if each bit is a 1 or a 0, combine bits into bytes, and determine the hex value? Let the oscilloscope do it for you! Once you've set up a bus, the MSO/DPO4000B Series will decode each packet on the bus, and display the value in hex, binary, decimal (USB, Ethernet, MIL-STD-1553, LIN, and FlexRay only), signed decimal (I2S/LJ/RJ/TDM only), or ASCII (USB, Ethernet, and RS-232/422/485/UART only) in the bus waveform. Event Table In addition to seeing decoded packet data on the bus waveform itself, you can view captured packets in a tabular view much like you would see in a software listing. Packets are time stamped and listed consecutively with columns for each component (Address, Data, etc.). Event table data can be saved to .csv format. Search Serial triggering is very useful for isolating the event of interest, but once you've captured it and need to analyze the surrounding data, what do you do? In the past, users had to manually scroll through the waveform counting and converting bits and looking for what caused the event. With the MSO/DPO4000B Series, you can have the oscilloscope automatically search through the acquired data for user-defined criteria including serial packet content. Each occurrence is highlighted by a search mark. Rapid navigation between marks is as simple as pressing the Previous () and Next () buttons on the front panel. www.tektronix.com 7 Data Sheet and tedious process. The MSO/DPO4000B Series optional power analysis tools greatly simplify these tasks, enabling quick and accurate analysis of power quality, switching loss, harmonics, safe operating area (SOA), modulation, ripple, and slew rate (di/dt, dv/dt). Completely integrated into the oscilloscope, the power analysis tools provide automated, repeatable power measurements with a touch of a button; no external PC or complex software setup is required. Limit/Mask Testing (Optional) Safe operating area measurement. Automated power measurements enable quick and accurate analysis of common power parameters. A common task during the development process is characterizing the behavior of certain signals in a system. One method, called limit testing, is to compare a tested signal to a known good or "golden" version of the same signal with user-defined vertical and horizontal tolerances. Another common method, called mask testing, is to compare a tested signal to a mask, looking for where a signal under test violates the mask. The MSO/DPO4000B Series offers both limit and mask testing capability useful for long-term signal monitoring, characterizing signals during design, or testing on a production line. A robust set of telecommunications and computer standards are provided to test for compliance to a standard. Additionally, custom masks can be created and used for characterizing signals. Tailor a test to your specific requirements by defining test duration in number of waveforms or time, a violation threshold that must be met before considering a test a failure, counting hits along with statistical information, and actions upon violations, test failure, and test complete. Whether specifying a mask from a known good signal or from a custom or standard mask, conducting pass/fail tests in search of waveform anomalies such as glitches has never been easier. Video Design and Development Limit Test showing a mask created from a golden waveform and compared against a live signal. Results showing statistical information about the test are displayed. Power Analysis (Optional) Ever increasing consumer demand for longer battery-life devices and for green solutions that consume less power require power-supply designers to characterize and minimize switching losses to improve efficiency. In addition, the supply's power levels, output purity, and harmonic feedback into the power line must be characterized to comply with national and regional power quality standards. Historically, making these and many other power measurements on an oscilloscope has been a long, manual, 8 www.tektronix.com Many video engineers have remained loyal to analog oscilloscopes, believing the intensity gradations on an analog display are the only way to see certain video waveform details. The MSO/DPO4000B Series fast waveform capture rate, coupled with its intensity-graded view of the signal, provides the same information-rich display as an analog oscilloscope, but with much more detail and all the benefits of digital oscilloscopes. Standard features such as IRE and mV graticules, holdoff by fields, video polarity, and an Autoset smart enough to detect video signals, make the MSO/DPO4000B Series the easiest to use oscilloscope on the market for video applications. And with up to a 1 GHz bandwidth and four analog inputs, the MSO/DPO4000B Series provides ample performance for analog and digital video use. The MSO/DPO4000B Series video functionality is further extended with the optional DPO4VID video application module. DPO4VID provides the industry's most complete suite of HDTV and custom (nonstandard) video triggers. Mixed Signal Oscilloscopes -- MSO4000B, DPO4000B Series The MSO/DPO4000B Series is designed to make your work easier. The large, high-resolution display shows intricate signal details. Dedicated front-panel controls simplify operation. Two USB host ports on the front panel allow you to easily transfer screenshots, instrument settings, and waveform data to a USB thumb drive. The MSO/DPO4000B Series' compact form factor frees up valuable space on your bench or desktop. Designed to Make Your Work Easier Large, High-resolution Display The MSO/DPO4000B Series features a 10.4 in. (264 mm) bright, LED backlit XGA color display for seeing intricate signal details. Dedicated Front-panel Controls Per-channel vertical controls provide simple and intuitive operation. No longer do you need to share one set of vertical controls across all four channels. Connectivity Two USB host ports on the front panel enable easy transfer of screenshots, instrument settings, and waveform data to a USB thumb drive. The rear panel contains two additional USB host ports and a USB device port for controlling the oscilloscope remotely from a PC or for connecting a USB keyboard. The USB device port can also be used to print directly to a PictBridge(R)-compatible printer. An integrated 10/100/1000BASE-T Ethernet port enables easy connection to networks and a Video Out port allows the oscilloscope display to be exported to an external monitor or projector. The instrument can mount external network drives for easy storage of screen images, setup files, or data files. Setup or data files can then be directly recalled and loaded into the oscilloscope from the network drive location. The MSO/DPO4000B Series is LXI Class-C compliant. Compact Form Factor A compact, portable form factor allows the MSO/DPO4000B Series to be easily moved between labs and, with a depth of just 5.8 in. (147 mm), it saves you valuable space on your test bench. TekVPI probe interface simplifies connecting your probes to the oscilloscope. TekVPI(R) Probe Interface The TekVPI probe interface sets the standard for ease of use in probing. In addition to the secure, reliable connection that the interface provides, TekVPI probes feature status indicators and controls, as well as a probe menu button right on the compensation box itself. This button brings up a probe menu on the oscilloscope display with all relevant settings and controls for the probe. The TekVPI interface enables direct attachment of current probes without requiring a separate power supply. TekVPI probes can be controlled remotely through USB, GPIB, or LAN, enabling more versatile solutions in ATE environments. www.tektronix.com 9 Data Sheet OpenChoice(R) Desktop software enables seamless connection between the oscilloscope and your PC. Extended Analysis Acquiring data and measurements from the MSO/DPO4000B Series is as simple as connecting a USB cable from the oscilloscope to your PC. Key software applications - NI LabVIEW SignalExpressTM Tektronix Edition, OpenChoice(R) Desktop, and Microsoft Excel and Word toolbars - are included standard with each oscilloscope to enable fast and easy direct communication with your Windows PC. NI LabVIEW SignalExpress Tektronix Edition enables you to instantly acquire, generate, analyze, compare, import, and save measurement data and signals using an intuitive drag-and-drop user interface that does not require any programming. The optional Professional Version offers over 200 built-in functions that provide additional signal processing, advanced analysis, sweeping, and user-defined step capabilities. 10 www.tektronix.com The LXI web interface provides access to network settings, enables remote instrument control and is accessible from any standard web browser. For simple tasks, the included OpenChoice Desktop enables fast and easy communication between the oscilloscope and your PC through USB or LAN for transferring settings, waveforms, and screen images. The MSO/DPO4000B Series can also be connected to your network using the LAN port. The included LXI web interface provides information about the current configuration of your MSO/DPO4000B Series oscilloscope, including network configuration. The LXI web interface also provides remote instrument control through the popular e*Scope web-based instrument control capability. You can make changes to the network configuration, control instrument settings, save screen images and instrument data, and save/load instrument setups of your MSO/DPO4000B Series oscilloscope directly from the web interface through a password-protected web page. Mixed Signal Oscilloscopes -- MSO4000B, DPO4000B Series Characteristics Vertical System Analog Channels Characteristic Input Channels Analog Bandwidth (-3 dB) 5 mV/div 1 V/div Calculated Rise Time 5 mV/div (typical) Hardware Bandwidth Limits Input Coupling Input Impedance Input Sensitivity, 1 M Input Sensitivity, 50 Vertical Resolution Max Input Voltage, 1 M Max Input Voltage, 50 DC Gain Accuracy Channel-to-Channel Isolation DPO4034B MSO4034B DPO4054B MSO4054B DPO4104B MSO4104B 350 MHz 4 500 MHz 1 GHz 1 ns 700 ps 350 ps 20 MHz or 250 MHz AC, DC 1 M 1%, 50 1% 1 mV/div to 10 V/div 1 mV/div to 1 V/div 8 bits (11 bits with Hi Res) 300 VRMS CAT II with peaks 425 V 5 VRMS with peaks < 20 V 1.5%, derated at 0.10%/C above 30 C 100:1 at 100 MHz and 30:1 at >100 MHz up to the rated bandwidth for any two channels having equal volts/div settings Offset Range Horizontal System Analog Channels Range 1 M 50 1 mV/div to 50 mV/div 50.5 mV/div to 99.5 mV/div 100 mV/div to 500 mV/div 505 mV/div to 995 mV/div 1 V/div to 5 V/div 5.05 V/div to 10 V/div 1 V 0.5 V 1 V 0.5 V 10 V 5 V 100 V 50 V 10 V 5 V 5 V NA Vertical System Digital Channels Characteristic All MSO4000B Models Input Channels Thresholds Threshold Selections User-defined Threshold Range Maximum Input Voltage Threshold Accuracy Input Dynamic Range 16 Digital (D15 - D0) Per-channel Thresholds TTL, CMOS, ECL, PECL, User Defined 40 V Minimum Voltage Swing Input Impedance Probe Loading Vertical Resolution 42 Vpeak (100 mV + 3% of threshold setting) 30 Vp-p 200 MHz 10 Vp-p >200 MHz 400 mV 100 k 3 pF 1 bit Characteristic DPO4034B MSO4034B DPO4054B MSO4054B DPO4104B MSO4104B 2.5 GS/s 2.5 GS/s 5 GS/s Maximum Sample Rate (All channels) Maximum Record Length (All channels) Maximum Duration at Highest Sample Rate (All channels) Time Base Range Time Base Delay Time Range Channel-to-Channel Deskew Range Time Base Accuracy 20M points 8 ms 8 ms 4 ms 1 ns to 1,000 s 400 ps to 1,000 s -10 divisions to 5000 s 125 ns 5 ppm over any 1 ms interval Horizontal System Digital Channels Characteristic All MSO4000B Models Maximum Sample Rate (Main) Maximum Record Length (Main) Maximum Sample Rate (MagniVu) Maximum Record Length (MagniVu) Minimum Detectable Pulse Width (Typical) Channel-to-Channel Skew (Typical) Maximum Input Toggle Rate 500 MS/s (2 ns resolution) 20M points 16.5 GS/s (60.6 ps resolution) 10k points centered around the trigger 1 ns 200 ps 500 MHz Maximum frequency sine wave that can accurately be reproduced as a logic square wave. Requires the use of a short ground extender on each channel. This is the maximum frequency at the minimum swing amplitude. Higher toggle rates can be achieved with higher amplitudes. www.tektronix.com 11 Data Sheet Trigger System Trigger Level Range Characteristic Description Characteristic Description Main Trigger Modes Auto, Normal, and Single Any Channel 8 divisions from center of screen Trigger Coupling DC, AC, HF reject (attenuates >50 kHz), LF reject (attenuates <50 kHz), noise reject (reduces sensitivity) External (Auxiliary Input) 8 V Trigger Holdoff Range 20 ns to 8 s Line Fixed at about 50% of line voltage Trigger Frequency Readout Provides 6-digit frequency readout of triggerable events. Trigger Sensitivity Characteristic Description Internal DC Coupled 1 M Path (All models) For 1 mV/div to 4.98 mV/div; 0.75 div from DC to 50 MHz, increasing to 1.3 div at rated bandwidth 50 Path (MSO/DPO4054B, MSO/DPO4034B) For 5 mV/div; 0.4 div from DC to 50 MHz, increasing to 1 div at rated bandwidth 50 Path (MSO/DPO4104B) 0.4 div from DC to 50 MHz, increasing to 1 div at rated bandwidth External Auxiliary Input 200 mV from DC to 50 MHz, increasing to 500 mV at rated bandwidth Trigger Modes Mode Description Edge Sequence (B-trigger) Pulse Width Timeout Runt Logic Positive or negative slope on any channel or front-panel auxiliary input. Coupling includes DC, AC, HF reject, LF reject, and noise reject Trigger Delay by Time - 4 ns to 8 s. Or Trigger Delay by Events - 1 to 4,000,000 events Trigger on width of positive or negative pulses that are >, <, =, or a specified period of time (4 ns to 8 s) Trigger when no pulse is detected within a specified time (4 ns to 8 s) Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again Trigger when any logical pattern of channels goes false or stays true for specified period of time (4 ns to 8 s). Any input can be used as a clock to look for the pattern on a clock edge. Pattern (AND, OR, NAND, NOR) specified for all analog and digital input channels defined as High, Low, or Don't Care Trigger on violations of both setup time and hold time between clock and data present on any of the input channels Trigger on pulse edge rates that are faster or slower than specified. Slope may be positive, negative, or either Trigger on all lines, odd, even, or all fields on NTSC, PAL, and SECAM video signals Trigger on 480p/60, 576p/50, 720p/30, 720p/50, 720p/60, 875i/60, 1080i/50, 1080i/60, 1080p/24, 1080p/24sF, 1080p/25, 1080p/30, 1080p/50, 1080p/60, and custom bi-level and tri-level sync video standards Trigger on Start, Repeated Start, Stop, Missing ACK, Address (7 or 10 bit), Data, or Address and Data on I2C buses up to 10 Mb/s Trigger on SS active, MOSI, MISO, or MOSI and MISO on SPI buses up to 50 Mb/s Setup and Hold Rise/Fall Time Video Extended Video (Optional) I2C (Optional) SPI (Optional) 12 www.tektronix.com Mixed Signal Oscilloscopes -- MSO4000B, DPO4000B Series Mode Description USB (Optional) Low-speed: Trigger on Sync, Reset, Suspend, Resume, End of Packet, Token (Address) Packet, Data Packet, Handshake Packet, Special Packet, Error. Token packet trigger - Any token type, SOF, OUT, IN, SETUP; Address can be specified for Any Token, OUT, IN, and SETUP token types. Address can be further specified to trigger on , <, =, >, , a particular value, or inside or outside of a range. Frame number can be specified for SOF token using binary, hex, unsigned decimal and don't care digits. Data packet trigger - Any data type, DATA0, DATA1; Data can be further specified to trigger on , <, =, >, , a particular data value, or inside or outside of a range. Handshake packet trigger - Any handshake type, ACK, NAK, STALL. Special packet trigger - Any special type, Reserved. Error trigger - PID Check, CRC5 or CRC16, Bit Stuffing. Full-speed: Trigger on Sync, Reset, Suspend, Resume, End of Packet, Token (Address) Packet, Data Packet, Handshake Packet, Special Packet, Error. Token packet trigger - Any token type, SOF, OUT, IN, SETUP; Address can be specified for Any Token, OUT, IN, and SETUP token types. Address can be further specified to trigger on , <, =, >, , a particular value, or inside or outside of a range. Frame number can be specified for SOF token using binary, hex, unsigned decimal and don't care digits. Data packet trigger - Any data type, DATA0, DATA1; Data can be further specified to trigger on , <, =, >, , a particular data value, or inside or outside of a range. Handshake packet trigger - Any handshake type, ACK, NAK, STALL. Special packet trigger - Any special type, PRE, Reserved. Error trigger - PID Check, CRC5 or CRC16, Bit Stuffing. High-speed: Trigger on Sync, Reset, Suspend, Resume, End of Packet, Token (Address) Packet, Data Packet, Handshake Packet, Special Packet, Error. Token packet trigger - Any token type, SOF, OUT, IN, SETUP; Address can be specified for Any Token, OUT, IN, and SETUP token types. Address can be further specified to trigger on , <, =, >, , a particular value, or inside or outside of a range. Frame number can be specified for SOF token using binary, hex, unsigned decimal and don't care digits. Data packet trigger - Any data type, DATA0, DATA1, DATA2, DATAM; Data can be further specified to trigger on , <, =, >, , a particular data value, or inside or outside of a range. Handshake packet trigger - Any handshake type, ACK, NAK, STALL, NYET. Special packet trigger - Any special type, ERR, SPLIT, PING, Reserved. SPLIT packet components that can be specified include: Hub Address Start/Complete - Don't Care, Start (SSPLIT), Complete (CSPLIT) Port Address Start and End bits - Don't Care, Control/Bulk/Interrupt (Full-speed Device, Low-speed Device), Isochronous (Data is Middle, Data is End, Data is Start, Data is All) Endpoint Type - Don't Care, Control, Isochronous, Bulk, Interrupt Error trigger - PID Check, CRC5 or CRC16, Any. Ethernet (Optional) CAN (Optional) LIN (Optional) FlexRay (Optional) RS-232/422/485/UART (Optional) High-speed support only available on MSO4104B and DPO4104B models. 10BASE-T: Trigger on Start Frame Delimiter, MAC Addresses, MAC Q-Tag Control Information, MAC Length/Type, IP Header, TCP Header, TCP/IPv4/MAC Client Data, End of Packet, FCS (CRC) Error. MAC Addresses - Trigger on Source and Destination 48-bit address values. MAC Q-Tag Control Information - Trigger on Q-Tag 32-bit value. MAC Length/Type - Trigger on , <, =, >, , a particular 16-bit value, or inside or outside of a range. IP Header - Trigger on IP Protocol 8-bit value, Source Address, Destination Address. TCP Header - Trigger on Source Port, Destination Port, Sequence Number, and Ack Number. TCP/IPv4/MAC Client Data - Trigger on , <, =, >, , a particular data value, or inside or outside of a range. Selectable number of bytes to trigger on from 1-16. Byte offset options of Don't Care, 0-1499. 100BASE-TX: Trigger on Start Frame Delimiter, MAC Addresses, MAC Q-Tag Control Information, MAC Length/Type, IP Header, TCP Header, TCP/IPv4/MAC Client Data, End of Packet, FCS (CRC) Error, Idle. MAC Addresses - Trigger on Source and Destination 48-bit address values. MAC Q-Tag Control Information - Trigger on Q-Tag 32-bit value. MAC Length/Type - Trigger on , <, =, >, , a particular 16-bit value, or inside or outside of a range. IP Header - Trigger on IP Protocol 8-bit value, Source Address, Destination Address. TCP Header - Trigger on Source Port, Destination Port, Sequence Number, and Ack Number. TCP/IPv4/MAC Client Data - Trigger on , <, =, >, , a particular data value, or inside or outside of a range. Selectable number of bytes to trigger on from 1-16. Byte offset options of Don't Care, 0-1499. Trigger on Start of Frame, Frame Type (data, remote, error, overload), Identifier (standard or extended), Data, Identifier and Data, End of Frame, Missing ACK, or Bit Stuffing Error on CAN signals up to 1 Mb/s. Data can be further specified to trigger on , <, =, >, , or a specific data value. User-adjustable sample point is set to 50% by default Trigger on Sync, Identifier, Data, Identifier and Data, Wakeup Frame, Sleep Frame, Errors such as Sync, Parity, or Checksum Errors up to 100 Kb/s (by LIN definition, 20 Kb/s) Trigger on Start of Frame, Type of Frame (Normal, Payload, Null, Sync, Startup), Identifier, Cycle Count, Complete Header Field, Data, Identifier and Data, End of Frame or Errors such as Header CRC, Trailer CRC, Null Frame, Sync Frame, or Startup Frame Errors up to 100 Mb/s Trigger on Tx Start Bit, Rx Start Bit, Tx End of Packet, Rx End of Packet, Tx Data, Rx Data, Tx Parity Error, and Rx Parity Error up to 10 Mb/s www.tektronix.com 13 Data Sheet Mode Description MIL-STD-1553 (Optional) Trigger on Sync, Word Type*1 (Command, Status, Data), Command Word*1 (set RT Address, T/R, Sub-address/Mode, Data Word Count/Mode Code, and Parity individually), Status Word*1 (set RT Address, Message Error, Instrumentation, Service Request Bit, Broadcast Command Received, Busy, Subsystem Flag, Dynamic Bus Control Acceptance (DBCA), Terminal Flag, and Parity individually), Data Word (user-specified 16-bit data value), Error (Sync, Parity, Manchester, Non-contiguous data), Idle Time (minimum time selectable from 4 s to 100 s; maximum time selectable from 12 s to 100 s; trigger on < minimum, > maximum, inside range, outside range). RT Address can be further specified to trigger on =, , <, >, , a particular value, or inside or outside of a range. Trigger on Word Select, Frame Sync, or Data. Data can be further specified to trigger on , <, =, >, , a specific data value, or inside or outside of a range Maximum data rate for I2S/LJ/RJ is 12.5 Mb/s Maximum data rate for TDM is 25 Mb/s Trigger on a parallel bus data value. Parallel bus can be from 1 to 20 bits in size. Binary and Hex radices are supported I2S/LJ/RJ/TDM (Optional) Parallel (Available on MSO models only) *1 Trigger selection of Command Word will trigger on Command and ambiguous Command/Status words. Trigger selection of Status Word will trigger on Status and ambiguous Command/Status words. Acquisition Modes Waveform Math Mode Description Characteristic Description Sample Acquire sampled values Arithmetic Add, subtract, multiply, and divide waveforms Peak Detect Captures glitches as narrow as 800 ps (1 GHz models) or 1.6 ns (500 MHz and 350 MHz models) at all sweep speeds Math Functions Integrate, Differentiate, FFT FFT Spectral magnitude Averaging From 2 to 512 waveforms included in average FFT Vertical Scale: Linear RMS or dBV RMS Envelope Min-Max envelope reflecting Peak Detect data over multiple acquisitions FFT Window Settings: Rectangular, Hamming, Hanning, Blackman Harris Hi Res Real-time boxcar averaging reduces random noise and increases vertical resolution Roll Scrolls waveforms right to left across the screen at sweep speeds slower than or equal to 40 ms/div Advanced Math Waveform Measurements Measurement Description Cursors Waveform and Screen Automatic Measurements 29, of which up to eight can be displayed on-screen at any one time. Measurements include: Period, Frequency, Delay, Rise Time, Fall Time, Positive Duty Cycle, Negative Duty Cycle, Positive Pulse Width, Negative Pulse Width, Burst Width, Phase, Positive Overshoot, Negative Overshoot, Peak-to-Peak, Amplitude, High, Low, Max, Min, Mean, Cycle Mean, RMS, Cycle RMS, Positive Pulse Count, Negative Pulse Count, Rising Edge Count, Falling Edge Count, Area and Cycle Area Measurement Statistics Mean, Min, Max, Standard Deviation Reference Levels User-definable reference levels for automatic measurements can be specified in either percent or units Gating Waveform Histogram Waveform Histogram Measurements 14 www.tektronix.com Isolate the specific occurrence within an acquisition to take measurements on, using either the screen or waveform cursors A waveform histogram provides an array of data values representing the total number of hits inside of a user-defined region of the display. A waveform histogram is both a visual graph of the hit distribution as well as a numeric array of values that can be measured. Sources - Channel 1, Channel 2, Channel 3, Channel 4, Ref 1, Ref 2, Ref 3, Ref 4, Math Types - Vertical, Horizontal Waveform Count, Hits in Box, Peak Hits, Median, Max, Min, Peak-to-Peak, Mean, Standard Deviation, Sigma 1, Sigma 2, Sigma 3 Define extensive algebraic expressions including waveforms, reference waveforms, math functions. Perform math on math using complex equations (FFT, Intg, Diff, Log, Exp, Sqrt, Abs, Sine, Cosine, Tangent, Rad, Deg), scalars, up to two user-adjustable variables and results of parametric measurements (Period, Freq, Delay, Rise, Fall, PosWidth, NegWidth, BurstWidth, Phase, PosDutyCycle, NegDutyCycle, PosOverShoot, NegOverShoot, PeakPeak, Amplitude, RMS, CycleRMS, High, Low, Max, Min, Mean, CycleMean, Area, CycleArea, and trend plots) e.g. (Intg(Ch1-Mean(Ch1))x1.414xVAR1) Power Measurements (Optional) Measurement Description Power Quality Measurements VRMS, VCrest Factor, Frequency, IRMS, ICrest Factor, True Power, Apparent Power, Reactive Power, Power Factor, Phase Angle Switching Loss Measurements Power Loss: Ton, Toff, Conduction, Total Harmonics THD-F, THD-R, RMS measurements Energy Loss: Ton, Toff, Conduction, Total Graphical and table displays of harmonics Test to IEC61000-3-2 Class A and MIL-STD-1399 Section 300A Ripple Measurements Vripple and Iripple Modulation Analysis Graphical display of +Pulse Width, -Pulse Width, Period, Frequency, +Duty Cycle, and -Duty Cycle modulation types Safe Operating Area Graphical display and mask testing of switching device safe operating area measurements dV/dt and dI/dt Measurements Cursor measurements of slew rate Mixed Signal Oscilloscopes -- MSO4000B, DPO4000B Series Limit/Mask Testing (Optional) Characteristic Description Included Standard Masks ITU-T, ANSI T1.102, USB Test Source Limit Test: Any Ch1 - Ch4 or any R1 - R4 Mask Test: Any Ch1 - Ch4 Mask Creation Limit test vertical tolerance from 0 to 1 division in 1 m division increments; Limit test horizontal tolerance from 0 to 500 m division in 1 m division increments Load standard mask from internal memory Load custom mask from text file with up to 8 segments Mask Scaling Lock to Source ON (mask automatically re-scales with source-channel settings changes) Lock to Source OFF (mask does not re-scale with source-channel settings changes) Test Criteria Run Until Minimum number of waveforms (from 1 to 1,000,000; Infinity) Minimum elapsed time (from 1 second to 48 hours; Infinity) Violation Threshold From 1 to 1,000,000 Actions on Test Failure Stop acquisition, save screen image to file, save waveform to file, print screen image, trigger out pulse, set remote interface SRQ Actions on Test Complete Trigger out pulse, set remote interface SRQ Results Display Test status, total waveforms, number of violations, violation rate, total tests, failed tests, test failure rate, elapsed time, total hits for each mask segment Software Software Description NI LabVIEW SignalExpress Tektronix Edition A fully interactive measurement software environment optimized for the MSO/DPO4000B Series, enables you to instantly acquire, generate, analyze, compare, import, and save measurement data and signals using an intuitive drag-and-drop user interface that does not require any programming. Standard MSO/DPO4000B Series support for acquiring, controlling, viewing, and exporting your live signal data is permanently available through the software. The full version (SIGEXPTE) adds additional signal processing, advanced analysis, mixed signal, sweeping, limit testing, and user-defined step capabilities and is available for a 30-day trial period standard with each instrument. Enables fast and easy communication between a Windows PC and the MSO/DPO4000B Series, using USB or LAN. Transfer and save settings, waveforms, measurements, and screen images. Included Word and Excel toolbars automate the transfer of acquisition data and screen images from the oscilloscope into Word and Excel for quick reporting or further analysis. Provides a standard instrument programming interface for common applications such as LabVIEW, LabWindows/CVI, Microsoft .NET and MATLAB. Enables control of the MSO/DPO4000B Series over a network connection through a standard web browser. Simply enter the IP address or network name of the oscilloscope and a web page will be served to the browser. Connect to the MSO/DPO4000B Series through a standard web browser by simply entering the oscilloscope's IP address or network name in the address bar of the browser. The web interface enables viewing of instrument status and configuration, status and modification of network settings, and instrument control through the e*scope web-based remote control. All web interaction conforms to LXI Class C specification. OpenChoice(R) Desktop IVI Driver e*Scope(R) Web-based Remote Control LXI Class C Web Interface Display Characteristics Characteristic Description Display Type Display Resolution Waveform Styles 10.4 in. (264 mm) liquid-crystal TFT color display 1,024 horizontal x 768 vertical pixels (XGA) Vectors, Dots, Variable Persistence, Infinite Persistence Full, Grid, Solid, Cross Hair, Frame, IRE, and mV YT and simultaneous XY/YT >50,000 wfm/s maximum Graticules Format Waveform Capture Rate Input/Output Ports Port Description USB 2.0 High-speed Host Supports USB mass storage devices, printers and Port keyboard. Two ports on front and two ports on rear of instrument USB 2.0 Device Port Rear-panel connector allows for communication/control of oscilloscope through USBTMC or GPIB (with a TEK-USB-488), and direct printing to all PictBridge-compatible printers LAN Port RJ-45 connector, supports 10/100/1000 Mb/s XGA Video Port DB-15 female connector, connect to show the oscilloscope display on an external monitor or projector Auxiliary Input Front-panel BNC connector. Input Impedance 1 M. Max input 300 VRMS CAT II with peaks 425 V Front-panel pins Probe Compensator Amplitude: 2.5 V Output Frequency: 1 kHz Auxiliary Out Rear-panel BNC connector VOUT (Hi): 2.5 V open circuit, 1.0 V 50 to ground VOUT (Lo): 0.7 V into a load of 4 mA; 0.25 V 50 to ground External Reference In Kensington Lock VESA Mount Output can be configured to provide a pulse out signal when the oscilloscope triggers, the internal oscilloscope reference clock out, or an event out for limit/mask testing Time-base system can phase lock to an external 10 MHz reference (10 MHz 1%) Rear-panel security slot connects to standard Kensington lock Standard (MIS-D 100) 100 mm VESA mounting points on rear of instrument LAN eXtensions for Instrumentation (LXI) Characteristic Description Class Version LXI Class C V1.3 Power Source Characteristic Description Power Source Voltage 100 to 240 V 10% Power Source Frequency 45 to 66 Hz (85 to 264 V) 360 to 440 Hz (100 to 132 V) 225 W maximum Power Consumption www.tektronix.com 15 Data Sheet Ordering Information Physical Characteristics Dimensions mm in. Height Width Depth 229 439 147 9.0 17.3 5.8 MSO/DPO4000B Family Weight kg lb. DPO4034B 5 Net 11 10.7 23.6 Shipping Rackmount Configuration 5U Cooling Clearance 2 in. (51 mm) required on left side and rear of instrument Temperature Operating Nonoperating Humidity Operating Nonoperating Altitude Operating Nonoperating Regulatory Electromagnetic Compatibility Safety 16 www.tektronix.com Description Description DPO4000B Models DPO4054B DPO4104B 350 MHz, 2.5 GS/s, 20M record length, 4-channel digital phosphor oscilloscope 500 MHz, 2.5 GS/s, 20M record length, 4-channel digital phosphor oscilloscope 1 GHz, 5 GS/s, 20M record length, 4-channel digital phosphor oscilloscope MSO4000B Models MSO4034B Environmental Characteristic Model MSO4054B 350 MHz, 2.5 GS/s, 20M record length, 4+16 channel mixed signal oscilloscope 500 MHz, 2.5 GS/s, 20M record length, 4+16 channel mixed signal oscilloscope 1 GHz, 5 GS/s, 20M record length, 4+16 channel mixed signal oscilloscope 0 C to +50 C -20 C to +60 C MSO4104B High: 40 C to 50 C, 10% to 60% Relative Humidity Low: 0 C to 40 C, 10% to 90% Relative Humidity High: 40 C to 60 C, 5% to 60% Relative Humidity Low: 0 C to 40 C, 5% to 90% Relative Humidity All Models Include: One passive voltage probe per analog channel (TPP0500 500 MHz, 10X, 3.9 pF for 500 MHz and 350 MHz models; TPP1000 1 GHz, 10X, 3.9 pF for 1 GHz models), Front Cover (200-5130-xx), User Manual (071-2810-xx), Documentation CD (063-4300-xx), OpenChoice(R) Desktop Software, NI LabVIEW SignalExpressTM Tektronix Edition Software, Calibration Certificates document measurement traceability to National Metrology Institute(s) - the Quality System this product is manufactured in is ISO9001 registered, power cord, accessory bag (016-2030-xx) and a three-year warranty. Please specify power plug and manual language version when ordering. 9,843 ft. (3,000 m) 30,000 ft. (9,144 m) EC Council Directive 2004/108/EC UL61010-1, Second Edition; CSA61010-1 Second Edition, EN61010-1:2001; IEC 61010-1:2001 MSO Models also Include: One P6616 16-channel logic probe and a logic probe accessory kit (020-2662-xx). Mixed Signal Oscilloscopes -- MSO4000B, DPO4000B Series Application Modules Module Description Application modules have licenses which can be transferred between an application module and an oscilloscope. The license may be contained in the module; allowing the module to be moved from one instrument to another. Or, the license can be contained in the oscilloscope; allowing the module to be removed and stored for safekeeping. Transferring the license to an oscilloscope and removing the module permits the use of more than 4 applications simultaneously. DPO4COMP Computer Serial Triggering and Analysis Module. Enables triggering on packet-level information on RS-232/422/485/UART buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time-stamp information. Signal Inputs - Any Ch1 - Ch4 (and any D0 - D15 on MSO models; single-ending probing only) Recommended Probing - RS-232/UART: Single ended; RS-422/485: Differential Embedded Serial Triggering and Analysis Module. Enables triggering on packet-level information on I2C and SPI buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time-stamp information. Signal Inputs - I2C: Any Ch1 - Ch4 (and any D0 - D15 on MSO models); SPI: Any Ch1 - Ch4 (and any D0 D15 on MSO models) Recommended Probing - I2C, SPI: Single ended Ethernet Serial Triggering and Analysis Module. Enables triggering on packet-level information on 10BASE-T and 100BASE-TX buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time-stamp information. Signal Inputs - Any Ch1 - Ch4 for single-ended probing; Any Ch1 - Ch4, Math, Ref1 - Ref4 for differential probing Recommended Probing - 10BASE-T: Single ended or differential; 100BASE-TX: Differential USB Serial Triggering and Analysis Module. Enables triggering on packet-level content for low-speed, full-speed, and high-speed USB serial buses. Also enables analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time-stamp information for low-speed, full-speed, and high-speed USB serial buses. Signal Inputs - Low-speed and Full-speed: Any Ch1 - Ch4 (and any D0 - D15 on MSO models; for single-ending probing only); Low-speed, Full-speed, and High-speed: Any Ch1 - Ch4, Math, Ref1 - Ref4 Recommended Probing - Low-speed and Full-speed: Single ended or differential; High-speed: Differential USB high-speed supported only on MSO4104B and DPO4104B models Power Analysis Application Module. Enables quick and accurate analysis of power quality, switching loss, harmonics, safe operating area (SOA), modulation, ripple, and slew rate (dI/dt, dV/dt) Limit and Mask Testing Application Module. Enables testing against limit templates generated from "golden" waveforms and mask testing using custom or standard telecommunications or computer masks HDTV and Custom (nonstandard) Video Triggering Module Module Description DPO4AERO Aerospace Serial Triggering and Analysis Module. Enables triggering on packet-level information on MIL-STD-1553 buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time-stamp information. Signal Inputs - Any Ch1 - Ch4, Math, Ref1 - Ref4 Recommended Probing - Differential or single ended (only one single-ended signal required) Audio Serial Triggering and Analysis Module. Enables triggering on packet-level information on I2S, LJ, RJ, and TDM audio buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time-stamp information. Signal Inputs - Any Ch1 - Ch4 (and any D0 - D15 on MSO models) Recommended Probing - I2S, LJ, RJ, TDM: Single ended Automotive Serial Triggering and Analysis Module. Enables triggering on packet-level information on CAN and LIN buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time-stamp information. Signal Inputs - LIN: Any Ch1 - Ch4 (and any D0 - D15 on MSO models); CAN: Any Ch1 - Ch4 (and any D0 D15 on MSO models; single-ended probing only) Recommended Probing - LIN: Single ended; CAN: Single ended or differential Extended Automotive Serial Triggering and Analysis Module. Enables triggering on packet-level information on CAN, LIN, and FlexRay buses as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, packet decode tables with time-stamp information, and eye diagram analysis software. Signal Inputs - LIN: Any Ch1 - Ch4 (and any D0 - D15 on MSO models); CAN: Any Ch1 - Ch4 (and any D0 - D15 on MSO models; single-ended probing only); FlexRay: Any Ch1 - Ch4 (and any D0 - D15 on MSO models; single-ended probing only) Recommended Probing - LIN: Single ended; CAN, FlexRay: Single ended or differential DPO4AUDIO DPO4AUTO DPO4AUTOMAX DPO4EMBD DPO4ENET DPO4USB DPO4PWR DPO4LMT DPO4VID www.tektronix.com 17 Data Sheet Instrument Options Recommended Probes Power Plug Options Tektronix offers over 100 different probes to meet your application needs. For a comprehensive listing of available probes, please visit www.tektronix.com/probes. Option Description Opt. A0 Opt. A1 Opt. A2 Opt. A3 Opt. A5 Opt. A6 Opt. A10 Opt. A11 Opt. A12 Opt. A99 North America Universal Euro United Kingdom Australia Switzerland Japan China India Brazil No power cord or AC adapter Description TPP0500 500 MHz, 10X TekVPI(R) passive voltage probe with 3.9 pF input capacitance 500 MHz, 2X TekVPI passive voltage probe with 3.9 pF input capacitance 2.5 kV, 800 MHz, 50X TekVPI passive high-voltage probe 1 GHz, 10X TekVPI passive voltage probe with 3.9 pF input capacitance 1.5 GHz TekVPI active single-ended voltage probe 1.5 GHz TekVPI differential voltage probe with 25 V differential input voltage 1 GHz TekVPI differential voltage probe with 42 V differential input voltage 500 MHz TekVPI differential voltage probe with 42 V differential input voltage 20 MHz TekVPI 150 Ampere AC/DC current probe 120 MHz TekVPI 30 Ampere AC/DC current probe 750 V, 200 MHz high-voltage differential probe 1.5 kV, 200 MHz high-voltage differential probe 6 kV, 100 MHz high-voltage differential probe 2.5 kV, 500 MHz, 100X high-voltage passive probe TPP0502 TPP0850 TPP1000 TAP1500 TDP1500 TDP1000 TDP0500 Language Options*2 Option Description Opt. L0 Opt. L1 Opt. L2 Opt. L3 Opt. L4 Opt. L5 Opt. L6 Opt. L7 Opt. L8 Opt. L9 Opt. L10 Opt. L99 English manual French manual Italian manual German manual Spanish manual Japanese manual Portuguese manual Simplified Chinese manual Traditional Chinese manual Korean manual Russian manual No manual *2 Language options include a translated front-panel overlay for the selected language(s). Service Options*3 Option Description Opt. Opt. Opt. Opt. Opt. Opt. Calibration Service 3 years Calibration Service 5 years Calibration Data Report Calibration Data Report 3 years (with Opt. C3) Calibration Data Report 5 Years (with Opt. C5) Repair Service 5 years (including warranty) C3 C5 D1 D3 D5 R5 Probe *3 Probes and accessories are not covered by the oscilloscope warranty and service offerings. Refer to the datasheet of each probe and accessory model for its unique warranty and calibration terms. TCP0150 TCP0030 TMDP0200 THDP0200 THDP0100 P5100A *4 Requires TekVPI(R) to TekProbe BNC adapter (TPA-BNC). Recommended Accessories Accessory Description 077-0512-xx SIGEXPTE Service Manual (English only) NI LabVIEW SignalExpressTM Tektronix Edition Software (Full Version) MSO Support for Altera and Xilinx FPGAs TekVPI-to-TekProbe BNC Adapter GPIB-to-USB Adapter Soft Transit Case Hard Transit Case (Requires ACD4000B) Rackmount Kit Deskew Pulse Generator Deskew Fixture FPGAView-xx TPA-BNC TEK-USB-488 ACD4000B HCTEK54 RMD5000 TEK-DPG 067-1686-xx Warranty Three-year warranty covering all parts and labor, excluding probes. Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar. Product(s) complies with IEEE Standard 488.1-1987, RS-232-C, and with Tektronix Standard Codes and Formats. 18 www.tektronix.com Mixed Signal Oscilloscopes -- MSO4000B, DPO4000B Series www.tektronix.com 19 Data Sheet Contact Tektronix: ASEAN / Australasia (65) 6356 3900 Austria 00800 2255 4835* Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777 Belgium 00800 2255 4835* Brazil +55 (11) 3759 7627 Canada 1 800 833 9200 Central East Europe and the Baltics +41 52 675 3777 Central Europe & Greece +41 52 675 3777 Denmark +45 80 88 1401 Finland +41 52 675 3777 France 00800 2255 4835* Germany 00800 2255 4835* Hong Kong 400 820 5835 India 000 800 650 1835 Italy 00800 2255 4835* Japan 81 (3) 6714 3010 Luxembourg +41 52 675 3777 Mexico, Central/South America & Caribbean 52 (55) 56 04 50 90 Middle East, Asia, and North Africa +41 52 675 3777 The Netherlands 00800 2255 4835* Norway 800 16098 People's Republic of China 400 820 5835 Poland +41 52 675 3777 Portugal 80 08 12370 Republic of Korea 001 800 8255 2835 Russia & CIS +7 (495) 7484900 South Africa +41 52 675 3777 Spain 00800 2255 4835* Sweden 00800 2255 4835* Switzerland 00800 2255 4835* Taiwan 886 (2) 2722 9622 United Kingdom & Ireland 00800 2255 4835* USA 1 800 833 9200 * European toll-free number. If not accessible, call: +41 52 675 3777 Updated 10 February 2011 For Further Information. Tektronix maintains a comprehensive, constantly expanding collection of application notes, technical briefs and other resources to help engineers working on the cutting edge of technology. Please visit www.tektronix.com Copyright (c) Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks, or registered trademarks of their respective companies. 02 Dec 2011 www.tektronix.com 3GW-20156-13