VUO35-12NO7
3~ Rectifier Bridge
Standard Rectifier Module
-
~ +~ ~
Part number
VUO35-12NO7
Features / Ad vantages: Applications: Package:
Package with DCB ceramic
Improved temperature and power cycling
Planar passivated chips
Very low forward voltage drop
Very low leakage current
Diode for main rectification
For three phase bridge configurations
Supplies for DC power equipment
Input rectifiers for PWM inverter
Battery DC power supplies
Field supply for DC motors
PWS-A
Industry standard outline
RoHS compliant
Easy to mount with two screws
Base plate: Aluminium
internally DCB isolated
Advanced power cycling
RRM
1200
I35
FSM
400
DAV
V=V
A
A
=
=
I
3~
Rectifier
IXYS reserves the right to change limits, conditions and dimensions. 20130605aData according to IEC 60747and per semiconductor unless otherwise specified
© 2013 IXYS all rights reserved
VUO35-12NO7
V = V
A²s
A²s
A²s
A²s
Symbol Definition
Ratings
typ. max.
I
R
V
IA
V
F
1.10
R4.2 K/W
R
min.
35
V
RSM
V
40T = 25°C
VJ
T = °C
VJ
mA1.5V = V
R
T = 25°C
VJ
I = A
F
V
T = °C
C
85
P
tot
29 WT = 25°C
C
RK/W0.6
15
1200
max. non-repetitive reverse blocking voltage
reverse current
forward voltage drop
total power dissipation
Conditions Unit
1.38
T = 25°C
VJ
150
V
F0
V0.80T = °C
VJ
150
r
F
12.9 m
V1.01T = °C
VJ
I = A
F
V
15
1.38
I = A
F
45
I = A
F
45
threshold voltage
slope resistance for power loss calculation only
µA
125
V
RRM
V1200
max. re pe titive rev er se blockin g volt a ge T = 25°C
VJ
C
J
10
j
unction capacitance V = V;400 T = 25°Cf = 1 MHz
RVJ
pF
I
FSM
t = 10 ms; (50 Hz), sine T = 45°C
VJ
max. forward surge current
T = °C
VJ
150
I²t T = 45°C
value for fusing
T = °C150
V = 0 V
R
V = 0 V
R
V = 0 V
V = 0 V
t = 8,3 ms; (60 Hz), sine
t = 10 ms; (50 Hz), sine
t = 8,3 ms; (60 Hz), sine
t = 10 ms; (50 Hz), sine
t = 8,3 ms; (60 Hz), sine
t = 10 ms; (50 Hz), sine
t = 8,3 ms; (60 Hz), sine
VJ
R
VJ
R
T = °C
VJ
150
400
430
580
555
A
A
A
A
340
365
800
770
1200
DAV
d =rectangular
bridge output current
thermal resistance junction to case
thJC
thermal resistance case to heatsink
thCH
Rectifier
1300
IXYS reserves the right to change limits, conditions and dimensions. 20130605aData according to IEC 60747and per semiconductor unless otherwise specified
© 2013 IXYS all rights reserved
VUO35-12NO7
Ratings
XXXX-XXXX YYCW Lot#
Made in Germany
Circuit
Diagram
Product
Number
Date Code
Package
T
VJ
°C
M
D
Nm1.75
mounting torque 1.25
T
stg
°C125
storage temperature -40
Weight g100
Symbol Definition typ. max.min.Conditions
virt ua l j un ctio n temp eratu re
Unit
M
T
Nm1.75
terminal torque 1.25
VV
t = 1 second
V
t = 1 minute
isolation voltage
mm
mm
6.5
8.5
d
Spp/App
creepage distance on surface | striking distance through air
d
Spb/Apb
terminal to backside
I
RMS
RMS current 100 A
per terminal
150-40
terminal to terminal
PWS-A
Delivery Mode Quantity Code No.Part Number Marking on ProductOrdering
50/60 Hz, RMS; I 1 mA
ISOL
VUO35-12NO7 456632Box 20VUO35-12NO7Standard
2500
3000
ISOL
threshold voltage V0.8
m
V
0 max
R
0 max
slope resistance * 11.7
Equivalent Circuits for Simulation
T =
VJ
IV
0
R
0
Rectifier
150 °C
* on die level
IXYS reserves the right to change limits, conditions and dimensions. 20130605aData according to IEC 60747and per semiconductor unless otherwise specified
© 2013 IXYS all rights reserved
VUO35-12NO7
1.1
24
22
5
10
4.3
9927
45
921
45
55
6
4.8
8
7
M4
~~~
-
~ +~ ~
Outlines PWS-A
IXYS reserves the right to change limits, conditions and dimensions. 20130605aData according to IEC 60747and per semiconductor unless otherwise specified
© 2013 IXYS all rights reserved
VUO35-12NO7
011
200
400
600
800
0.4 0.6 0.8 1.0 1.2 1.4 1.6
0
10
20
30
40
50
60
10
-3
10
-2
10
-1
10
0
150
200
250
300
3
5
0
1 10 100 1000 10000 100000
0
1
2
3
4
5
0 25 50 75 100 125 150 17504812
0
4
8
12
16
0 25 50 75 100 125 150
0
4
8
12
16
20
24
28
32
Constants for Z
thJC
calculation:
iR
th
(K/W) t
i
(s)
1 0.194 0.024
2 0.556 0.070
3 0.450 3.250
4 3.000 9.300
0.8 x V
RRM
50 Hz
T
VJ
= 45°C
V
R
=0V
R
thJA
:
0.6 KW
0.8 KW
1KW
2KW
4KW
8KW
DC =
1
0.5
0.4
0.33
0.17
0.08
T
VJ
=
125°C
150°C
T
VJ
=25°C
T
VJ
=150°C
T
VJ
= 150°C
Fig. 1 Forward current vs.
voltage drop per diode
Fig. 2 Surge overload current
vs. time per diode
Fig. 3 I
2
tvs.timeperdiode
Fig. 4 Power dissipation vs. forward current
and ambient temperature per diode
Fig. 5 Max. forward current vs.
case temperature per diode
Fig. 6 Transient thermal impedance junction to case vs. time per diode
DC =
1
0.5
0.4
0.33
0.17
0.08
T
VJ
=45°C
Rectifier
IXYS reserves the right to change limits, conditions and dimensions. 20130605aData according to IEC 60747and per semiconductor unless otherwise specified
© 2013 IXYS all rights reserved