Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 8760 Multi-Conductor - Shielded Twisted Pair Cable For more Information please call 1-800-Belden1 General Description: 18 AWG stranded (16x30) tinned copper conductors, polyethylene insulation, twisted pair, overall Beldfoil(R) shield (100% coverage), 20 AWG stranded tinned copper drain wire, PVC jacket. Physical Characteristics (Overall) Conductor AWG: # Pairs AWG Stranding Conductor Material 1 18 16x30 TC - Tinned Copper Total Number of Conductors: 2 Insulation Insulation Material: Insulation Material Wall Thickness (mm) PO - Polyolefin 0.457 Outer Shield Outer Shield Material: Outer Shield Trade Name Type Outer Shield Material Beldfoil(R) Coverage (%) Tape Aluminum Foil-Polyester Tape w/Shorting Fold 100 Outer Shield Drain Wire AWG: AWG Stranding Drain Wire Conductor Material 20 7x28 TC - Tinned Copper Outer Jacket Outer Jacket Material: Outer Jacket Material Nom. Wall Thickness (mm) PVC - Polyvinyl Chloride 0.711 Overall Cable Overall Nominal Diameter: 5.639 mm Pair Pair Color Code Chart: Number Color 1 Black & Clear Mechanical Characteristics (Overall) Operating Temperature Range: -20C To +60C Bulk Cable Weight: 37.205 Kg/Km Max. Recommended Pulling Tension: 240.203 N Min. Bend Radius/Minor Axis: 57.150 mm Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: CM CEC/C(UL) Specification: CM Page 1 of 3 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 8760 Multi-Conductor - Shielded Twisted Pair Cable AWM Specification: UL Style 2092 (300 V 60C) EU Directive 2011/65/EU (ROHS II): Yes EU CE Mark: Yes EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/95/EC (RoHS): Yes EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004 EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Flame Test UL Flame Test: UL1685 UL Loading Suitability Suitability - Indoor: Yes Plenum/Non-Plenum Plenum (Y/N): No Plenum Number: 88760, 87760 or 82760 Electrical Characteristics (Overall) Nom. Inductance: Inductance (H/m) 0.59058 Nom. Capacitance Conductor to Conductor: Capacitance (pF/m) 89.243 Nom. Conductor DC Resistance: DCR @ 20C (Ohm/km) 21.3265 Max. Operating Voltage - UL: Voltage 300 V RMS Max. Recommended Current: Current 7.2 Amps per conductor @ 25C Put Ups and Colors: Item # Putup Ship Weight Color 8760 060U1000 305 MT 12.247 KG CHROME Notes Item Desc 2 #18 LDPE SH PVC 8760 060U500 152 MT 6.350 KG CHROME 2 #18 LDPE SH PVC 8760 0601000 305 MT 12.247 KG CHROME 8760 06010000 3,048 MT 122.471 KG CHROME CY 2 #18 LDPE SH PVC 8760 06010001 3,048 MT 122.471 KG CHROME CZ 2 #18 LDPE SH PVC 8760 06015000 4,572 MT 197.314 KG CHROME CY 2 #18 LDPE SH PVC 8760 0602000 610 MT 24.494 KG CHROME C 2 #18 LDPE SH PVC 8760 060250 76 MT 3.175 KG CHROME 8760 060500 152 MT 6.350 KG CHROME C 2 #18 LDPE SH PVC 8760 0605000 1,524 MT 65.771 KG CHROME C 2 #18 LDPE SH PVC 8760 0609999 305 MT 12.701 KG CHROME 2 #18 LDPE SH PVC 2 #18 LDPE SH PVC 2 #18 LDPE SH PVC Notes: C = CRATE REEL PUT-UP. Page 2 of 3 10-30-2013 Detailed Specifications & Technical Data METRIC MEASUREMENT VERSION 8760 Multi-Conductor - Shielded Twisted Pair Cable C = CRATE REEL PUT-UP. Y = FINAL PUT-UP LENGTH MAY VARY -10% TO +20% FROM LENGTH SHOWN.MAY CONTAIN 2 PIECES. MINIMUM LENGTH OF ANY ONE PIECE IS 1500'. Z = FINAL PUT-UP LENGTH MAY VARY (+ OR -) 10% FOR SPOOLS OR REELS AND(+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN. Revision Number: 3 Revision Date: 08-02-2012 (c) 2013 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the compliance date may be in stock at Belden facilities and in our Distributor's inventory. The information provided in this Product Disclosure, and the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product. Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC. Page 3 of 3 10-30-2013