General Description:
18 AWG stranded (16x30) tinned copper conductors, polyethylene insulation, twisted pair, overall Beldfoil®
shield (100% coverage), 20 AWG stranded tinned copper drain wire, PVC jacket.
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs AWG Stranding Conductor Material
118 16x30 TC - Tinned Copper
Total Number of Conductors: 2
Insulation
Insulation Material:
Insulation Material Wall Thickness (mm)
PO - Polyolefin 0.457
Outer Shield
Outer Shield Material:
Outer Shield Trade Name Type Outer Shield Material Coverage (%)
Beldfoil® Tape Aluminum Foil-Polyester Tape w/Shorting Fold 100
Outer Shield Drain Wire AWG:
AWG Stranding Drain Wire Conductor Material
20 7x28 TC - Tinned Copper
Outer Jacket
Outer Jacket Material:
Outer Jacket Material Nom. Wall Thickness (mm)
PVC - Polyvinyl Chloride 0.711
Overall Cable
Overall Nominal Diameter: 5.639 mm
Pair
Pair Color Code Chart:
Number Color
1Black & Clear
Mechanical Characteristics (Overall)
Operating Temperature Range: -20°C To +60°C
Bulk Cable Weight: 37.205 Kg/Km
Max. Recommended Pulling Tension: 240.203 N
Min. Bend Radius/Minor Axis: 57.150 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CM
CEC/C(UL) Specification: CM
Page 1 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
8760 Multi-Conductor - Shielded Twisted Pair Cable
AWM Specification: UL Style 2092 (300 V 60°C)
EU Directive 2011/65/EU (ROHS II): Yes
EU CE Mark: Yes
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
Flame Test
UL Flame Test: UL1685 UL Loading
Suitability
Suitability - Indoor: Yes
Plenum/Non-Plenum
Plenum (Y/N): No
Plenum Number: 88760, 87760 or 82760
Electrical Characteristics (Overall)
Nom. Inductance:
Inductance (µH/m)
0.59058
Nom. Capacitance Conductor to Conductor:
Capacitance (pF/m)
89.243
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
21.3265
Max. Operating Voltage - UL:
Voltage
300 V RMS
Max. Recommended Current:
Current
7.2 Amps per conductor @ 25°C
Put Ups and Colors:
Item # Putup Ship Weight Color Notes Item Desc
8760 060U1000 305 MT 12.247 KG CHROME 2 #18 LDPE SH PVC
8760 060U500 152 MT 6.350 KG CHROME 2 #18 LDPE SH PVC
8760 0601000 305 MT 12.247 KG CHROME 2 #18 LDPE SH PVC
8760 06010000 3,048 MT 122.471 KG CHROME C Y 2 #18 LDPE SH PVC
8760 06010001 3,048 MT 122.471 KG CHROME C Z 2 #18 LDPE SH PVC
8760 06015000 4,572 MT 197.314 KG CHROME C Y 2 #18 LDPE SH PVC
8760 0602000 610 MT 24.494 KG CHROME C 2 #18 LDPE SH PVC
8760 060250 76 MT 3.175 KG CHROME 2 #18 LDPE SH PVC
8760 060500 152 MT 6.350 KG CHROME C 2 #18 LDPE SH PVC
8760 0605000 1,524 MT 65.771 KG CHROME C 2 #18 LDPE SH PVC
8760 0609999 305 MT 12.701 KG CHROME 2 #18 LDPE SH PVC
Notes:
C = CRATE REEL PUT-UP.
Page 2 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
8760 Multi-Conductor - Shielded Twisted Pair Cable
C = CRATE REEL PUT-UP.
Y = FINAL PUT-UP LENGTH MAY VARY -10% TO +20% FROM LENGTH SHOWN.MAY CONTAIN 2 PIECES. MINIMUM LENGTH OF ANY ONE PIECE IS 1500'.
Z = FINAL PUT-UP LENGTH MAY VARY (+ OR -) 10% FOR SPOOLS OR REELS AND(+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN.
Revision Number: 3 Revision Date: 08-02-2012
© 2013 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications
described herein are subject to error or omission and to change without notice, and the listing of such information and specifications does not
ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with EU RoHS (Directive 2002/95/EC, 27-Jan-2003). Material manufactured prior to the
compliance date may be in stock at Belden facilities and in our Distributor’s inventory. The information provided in this Product Disclosure, and
the identification of materials listed as reportable or restricted within the Product Disclosure, is correct to the best of Belden’s knowledge,
information, and belief at the date of its publication. The information provided in this Product Disclosure is designed only as a general guide
for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not
to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for
determining the applicability of legislation and regulations based on their individual usage of the product.
Belden declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended by directive 93/68/EEC.
Page 3 of 3 10-30-2013
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
8760 Multi-Conductor - Shielded Twisted Pair Cable