TE30 20W-30W Single Output External Power Test & Measurement/Industrial Series Features Meets DoE Efficiency Level VI Requirements No load input power Average Efficiency Up to 30W of AC-DC Power Universal Input 90-264Vac Input Range Desktop and Wall-Plug versions Meets "Heavy Industrial" Levels of EN61000 EMC Requirements Meets EN55032/CISPR22 and FCC Part 15.109 Class B Conducted & Radiated Emissions, with 6db margin Approved to EN/IEC/UL60950-1, 2nd Ed., Am. 2 E-cap life of >8 years >1,000,000 hours MTBF 3 Year Warranty Description A high performance AC to DC external power supply family designed for test & measurement and industrial applications. The TE30A Series models are compliant with Efficiency Level VI requirements per U.S. Dept. of Energy, PLUS Heavy Industrial levels of various EN61000-4-x standards for EMC. Model Selection Model Number Volts Output Current Output Power Ripple & Noise Line Regulation Load Regulation TE30A0503F01 TE30A0903F01 TE30A1203F01 TE30A1503F01 TE30A1803F01 TE30A2403F01 TE30A4803F01 TE30A0503N01 TE30A0903N01 TE30A1203N01 TE30A1503N01 TE30A1803N01 TE30A2403N01 TE30A4803N01 TE30A0503Q01 TE30A0903Q01 TE30A1203Q01 TE30A1503Q01 TE30A1803Q01 TE30A2403Q01 TE30A4803Q01 TE30A0503B01 TE30A0903B01 TE30A1203B01 TE30A1503B01 TE30A1803B01 TE30A2403B01 TE30A4803B01 TE30A0503C01 TE30A0903C01 TE30A1203C01 TE30A1503C01 TE30A1803C01 TE30A2403C01 TE30A4803C01 5.0V 9.0V 12.0V 15.0V 18.0V 24.0V 48.0V 5.0V 9.0V 12.0V 15.0V 18.0V 24.0V 48.0V 5.0V 9.0V 12.0V 15.0V 18.0V 24.0V 48.0V 5.0V 9.0V 12.0V 15.0V 18.0V 24.0V 48.0V 5.0V 9.0V 12.0V 15.0V 18.0V 24.0V 48.0V 4.00A 3.00A 2.50A 2.00A 1.67A 1.33A 0.63A 4.00A 3.00A 2.50A 2.00A 1.67A 1.33A 0.63A 4.00A 3.00A 2.50A 2.00A 1.67A 1.33A 0.63A 4.00A 3.00A 2.50A 2.00A 1.67A 1.33A 0.63A 4.00A 3.00A 2.50A 2.00A 1.67A 1.33A 0.63A 20W 27W 30W 30W 30W 30W 30W 20W 27W 30W 30W 30W 30W 30W 20W 27W 30W 30W 30W 30W 30W 20W 27W 30W 30W 30W 30W 30W 20W 27W 30W 30W 30W 30W 30W 75mV pk-pk 90mV pk-pk 120mV pk-pk 150mV pk-pk 180mV pk-pk 240mV pk-pk 480mV pk-pk 75mV pk-pk 90mV pk-pk 120mV pk-pk 150mV pk-pk 180mV pk-pk 240mV pk-pk 480mV pk-pk 75mV pk-pk 90mV pk-pk 120mV pk-pk 150mV pk-pk 180mV pk-pk 240mV pk-pk 480mV pk-pk 75mV pk-pk 90mV pk-pk 120mV pk-pk 150mV pk-pk 180mV pk-pk 240mV pk-pk 480mV pk-pk 75mV pk-pk 90mV pk-pk 120mV pk-pk 150mV pk-pk 180mV pk-pk 240mV pk-pk 480mV pk-pk 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 1% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5% Notes: Output Connector Input Configuration 2.5 x 5.5 x 9.5mm Straight Barrel Type, center positive Class I Desktop, IEC60320 C14 Receptacle 2.5 x 5.5 x 9.5mm Straight Barrel Type, center positive Class II Desktop, IEC60320 C8 Receptacle 2.5 x 5.5 x 9.5mm Straight Barrel Type, center positive Class II Desktop, IEC60320 C18 Receptacle 2.5 x 5.5 x 9.5mm Straight Barrel Type, center positive 2.5 x 5.5 x 9.5mm Straight Barrel Type, center positive Class II Wall-Plug, Interchangeable Blades (North American Blade included) Class II Wall-Plug, Fixed North American Blades 1. Measured at the output connector, with noise probe directly across output and load terminated with 0.1F ceramic and 10F low ESR capacitors. For 5V and 6V models, values listed are typical, 100mV pk-pk maximum with 0.1F ceramic and 47F low ESR capacitors used at measurement point. 2. Order blade kit KT-1027K for other blades (EU. UK, Australia) 3. For EU fixed blades, replace "C" in the model number with "M", for UK blades, replace "C" with "G", for Australia blades, replace "C" with "H". 4. All specifications are typical at nominal input, full load, at 25C ambient unless noted. 5. For Input Class I models: For AC GND connected to output common (-), insert a "B" in the part number where the "A" is located (TE30B1203F01). www.slpower.com TE30 Rev 1.8 5-JAN-17 1 TE30 20W-30W Single Output External Power Test & Measurement/Industrial Series General Specifications AC Input Input Current Inrush Current Input Fuse Earth Leakage Current Efficiency 100-240Vac, 10%, 47-63Hz, 1 Turn On Time Less than 700mS @115Vac, full load 115Vac: 1.2A, 230Vac: 0.6A Hold-up Time 20mS min., at full Load, 100Vac input 264Vac, cold start: will not exceed 40A Overload Protection 2.0A, 250Vac Input-GND: <500A@264Vac, 60Hz, NC Output-GND: <4mA@264Vac, 60Hz, NC 20 to 30W continuous - See models chart for specific voltage model ratings. No Load Input Power <0.1W per DoE Efficiency Level VI Requirements Output Voltage Transient Response Regulation Drop Test Vibration Dimensions Weight Short Circuit Protection Overvoltage Protection Meets US DoE Efficiency Level VI Average efficiency levels Output Power Ripple and Noise Overtemperature Protection Isolation Hiccup Mode, auto recovery. Hiccup Mode. See model chart above for trip ranges. Input-Output: 4000Vac Input-Ground: 1500Vac Output-Ground: 1500Vac EN/CSA/UL/IEC 60950-1, 2nd Edition, Am 2 Operating Temperature -20C to +70C Start Up at -40C, full load, (warmup period before Temperature Derating See Derating Charts below. See models chart on pg 1. Storage Temperature Altitude See models chart on pg 1. 1.4m from table top to wooden platform, 4 faces. 130 to 180% of rating, Hiccup Mode Safety Standards See models chart on pg 1. 500s response time for return to within 0.5% of final value for any 50% load step over the range of 5% to 100% of rated load, i/t< 0.2A/s. Max. voltage deviation is +/-3.5%. Will shutdown upon an overtemperature condition, auto-recovery. Relative Humidity all parameters are within published specifications). -40C to +85C Operating: to 5000m. Non-operating: -500 to 40,000 ft. 5% to 95%, non-condensing Operating: 0.003g/Hz, 1.5grms overall, 3 axes, 10 min/axis, 1-500Hz. Non-Oper.: random waveform, 3 minutes per axis, 3 axes and Sine waveform, Vib. frequency/acceleration: 10-500Hz/1g, sweep rate of 1 octave / minutes, Vibration time of 10 sweeps / axes, 3 axes Shock Operating: Half-sine, 20gpk, 10mS, 3 axes, 6 shocks total Non-Operating: Half-sine waveform, impact acceleration of 100G, Pulse duration of 6 mS, Number of shocks: 3 for each of the three axis See outline drawings MTBF >1,000,000 hours, full load, 110 & 220Vac input, 25C amb., per Telcordia 332 Issue 6. E-Cap Life 250g >8 year life based on calculations at 115Vac/60Hz & 230Vac/50Hz, ambient 25C at 24 hrs per day, 365 days/year, 6 power up cycles per day. All specifications are typical at nominal input, full load, at 25C ambient unless noted. www.slpower.com TE30 Rev 1.8 5-JAN-17 2 TE30 20W-30W Single Output External Power Test & Measurement/Industrial Series EMI/EMC Compliance Conducted Emissions: EN55032/CISPR22 Class B, FCC Part 15, Class B: 6db margin typ, at 115 and 230Vac Radiated Emissions: EN55032/CISPR22 Class B, FCC Part 15, Class B: 3db margin typ, at 115 and 230Vac Common Mode Noise: High Frequency (100kHz-20MHz): <40mA pk-pk Electro-Static Discharge (ESD) Immunity on Power ports: EN55024/IEC61000-4-2, Level 4: +/- 8kV contact, +/- 15kV air, Criteria A Radiated RF EM Fields Susceptibility EN55022/EN61000-4-3, 10V/m, 80MHz-2.7GHz, 80% AM at 1kHz Electrical Fast Transients (EFT) /Bursts: EN55024/IEC61000-4-4, Level 4, +/- 4.4kV, 100Khz rep rate, 40A, Criteria A Surges, Line to Line (Diff Mode) and Line to GND (CMN Mode) Conducted Disturbances induced by RF Fields EN55024/IEC61000-4-5, Level 4, +/-2kV DM, +/-4kV CM, Criteria A EN55022/IEC61000-4-6, 3.6V/m - Level 4, 0.15 to 80Mhz; and 12V/m) in ISM and amateur radio bands between 0.15Mhz and 80Mhz, 80% AM at 1KHz Rated Power frequency magnetic fields EN55024/IEC1000-4-8, Level 4: 30 A/m, 50/60 Hz Voltage Interruptions, Dips, Sags & Surges EN55024/IECEN61000-4-11: --100% dip for 20mS, Criteria A --100% dip for 5000mS (250/300 cycles), Criteria B --60% dip for 100mS, Criteria B --30% dip for 500mS, Criteria A Harmonic Current Emissions EN55011/EN61000-3-2, Class A Flicker Test EN61000-3-3 All specifications are typical at nominal input, full load, at 25C ambient unless noted. Output Power Derating Output power is derated above 40C as follows, for operation over the entire AC input range (90-264Vac). 35 30 Output Power 25 20 5V Models 15 9V Models 12V-48V Models 10 5 0 -20 -10 0 10 20 30 40 50 60 70 Ambient Operating Temperature (C) www.slpower.com TE30 Rev 1.8 5-JAN-17 3 TE30 20W-30W Single Output External Power Test & Measurement/Industrial Series Mechanical Drawing 54 33.6 145050 Cable length for 5V and 9V models is 1200 +/- 50mm IEC60320 C14 Receptacle, 2.5 x 5.5 x 9.5mm Barrel Connector Notes: 145050 96 95.5 55 Cable length for 5V and 9V models is 1200 +/- 50mm Interchangeable N.A. Blade, 2.5 x 5.5 x 9.5mm barrel connector 1. All dimensions in mm. 2. Interchangeable blade models come with North American blade fitted. For other blades (EU, UK, Aust.) order blade kit KT1027K. Connector Information Standard models include a 2.5 x 5.5 x 9.5mm straight barrel type connector (Ault #3), center positive. Other standard options are listed below. The "03" in the standard model number is replaced by the applicable digits below: www.slpower.com TE30 Rev 1.8 5-JAN-17 4 TE30 20W-30W Single Output External Power Test & Measurement/Industrial Series Efficiency Level VI Information: TE30A Series 9V-48V models TE30A Series 5V models Data Sheet (c) 2017 SL Power Electronics Corp. The information and specifications contained herein are believed to be correct at the time of publication. However, SL Power accepts no responsibility for consequences arising from reproduction errors or inaccuracies. Specifications are subject to change without notice. www.slpower.com TE30 Rev 1.8 5-JAN-17 5