Low Voltage Supplementary Fuses 13 32" x 112" Fast-acting fuses BAF BAN KTK & KLM BAN-4 Catalog Numbers (Amps) BAF-210 BAF-2 BAF-8 BAF-14 BAF-2 12 BAF-9 BAF-12 BAF-3 BAF-10 BAF- 10 BAF-4 BAF-12 BAF-810 BAF-5 BAF-15 6 BAN-10 BAN-25 Recommended Fuse blocks 110 to 30A Catalog Numbers Terminal Type Screw with Quick Connect Pressure Plate w/ Quick Connect Box Lug Features and Benefits * Low cost supplemental protection of 600V or less non-inductive circuits. * Upgrade with LP-CC product to reduce SKU investment and minimize potential arc-flash hazards. Typical Applications * Control Circuits * Lighting Circuit Protection * Meter Circuits Catalog Numbers (Amps) 600Vac - UL Listed and CSA KTK-110 KTK- 34 KTK-4 KTK-12 KTK- 8 KTK-1 KTK-5 KTK-15 KTK- 210 KTK-1 14 KTK-6 KTK-20 KTK- 14 KTK-1 12 KTK-7 KTK-25 KTK- 310 KTK-2 KTK-7 12 KTK-30 KTK-35 1 Poles KTK- 410 KTK-2 12 KTK-8 BM6031SQ BM6031PQ BM6031B 1 KTK- 12 KTK-3 KTK-9 KTK-40 KTK- 610 KTK-3 12 KTK-10 KTK-45 BAF-1 BAF-6 BAF-20 BAF-1 12 BAF-6 14 BAF-25 BM6032SQ BM6032PQ BM6032B 2 BAF-1 810 BAF-7 BAF-30 BM6033SQ BM6033PQ BM6033B 3 KTK-50 *500Vac/dc - UL Recognized and CSA. *All have interrupting rating of 10,000A at 125V. KLM-110 KLM- 34 KLM-5 KLM-20 KLM- 8 KLM-1 KLM-6 KLM-25 KLM- 210 KLM-1 12 KLM-8 KLM-30 KLM- 14 KLM-2 KLM-10 KLM- 310 KLM-3 KLM-12 KLM- 12 KLM-4 KLM-15 1 Data Sheet: 2011 (0-30) Data Sheet: 2046 (0-30) For superior electrical protection, Cooper Bussmann recommends upgrading BAF, BAN and KTK fuse applications to Low-Peak LP-CC fuses See page 19. Recommended fuse blocks/fuse holders for 1332" x 112" fuses * See page 40 *KLM-( 110- 18A & 12-30A): 500Vac/600Vdc. Data Sheets: KTK-1011 KLM-2020 For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp 43 Low Voltage Supplementary Fuses Specifications Specifications Class: Supplemental Class: Supplemental Description: Fast-acting Description: Fast-acting supplementary fuse. supplementary fuse. 13 1 Dimensions: 32" x 1 2 Dimensions: 1332" x 1 12 (10.3 x 38.1mm). (10.3 x 38.1mm). Construction: Fibre Construction: Fibre tube. cartridge; nickel plated Ratings: brass endcaps. Volts -- 250Vac Ratings: Amps -- 1-30A Volts -- 250Vac (210-15A) IR -- 35A (1.1-3.5A) -- 125Vac (20-30A) -- 100A (3.6-10A) Amps -- 1-6A -- 200A (10.1-15A) IR -- 10,000A @ 125Vac (210-30A) -- 750A (15.1-30A) -- 35A (210-1A @ 250Vac) Features and Benefits -- 100A (112-6A @ 250Vac) * Low cost supplemental protection of 1 -- 200A (6 4-10A @ 250Vac) 125V and 250V non-inductive -- 750A (12A- 15A @ 250Vac) circuits. Agency Information: CE, Std. 248-14, * Upgrade with LP-CC product to UL 0-15/250V, Guide JDYX, File E19180 reduce SKU investment and miniCSA Certified, 0-15/250V, Class mize potential arc-flash hazards. 1422-01, File 53787. (and minimize potential for misapplying Features and Benefits fuse.) * Low cost supplemental protection of 125V and 250V non-inductive circuits. Typical Applications * Upgrade with LP-CC product to reduce * General Purpose Circuits SKU investment and minimize potential * Lighting Circuit Protection arc-flash hazards. (and minimize * Meter Circuits potential for misapplying fuse.) Catalog Numbers (Amps) Typical Applications BAN-1 BAN-5 BAN-12 BAN-30 * General Purpose Circuits BAN-2 BAN-6 BAN-15 * Lighting Circuit Protection BAN-3 BAN-8 BAN-20 * Meter Circuits Specifications Class: Supplemental Description: Fastacting supplementary fuse. Dimensions: 1332" x 1 12 (10.3 x 38.1mm). Construction: Melamine tube; nickel plated brass endcaps. Ratings: Volts -- KTK: 600Vac (or less) -- KLM: 500Vac/600Vdc (110A to 18A) -- 500Vac/dc (210-10A) -- 500Vac/600Vdc (12-30A) Amps -- 110-30A IR -- KTK: 100,000A RMS Sym. (UL) -- KLM: 10,000A RMS Sym. (UL) Agency Information: CE, Std. 248-14, KTK-UL Listed, Guide JDYX, File E19180, KLM-UL Recognized, Guide JFHR2, File E56412, CSA Certified, File 53787, Class 1422-01, HRC-Misc.