NOTES
1. Soldering operations
1) for manual soldering
Soldering should be accomplished in less
than 8 seconds with a 60 watt iron max.
(iron tip temperature: Max. 350
°
C 662
°
F)
2) For automatic soldering
Soldering should be done less than 10
seconds in 260
°
C 500
°
F solder bath or
less than 3 seconds in 350
°
C 662
°
F sol-
der bath.
2. Environment
Avoid using and keeping switches in the
following conditions.
• In corrosive gases
• In a dusty environment
• Where silicon atmosphere prevails
3. Quality check under actual loading
conditions
To assure reliability, check the switch un-
der actual loading conditions.
4. Recommended circuit for tip
Contact chattering may happen when vi-
bration or shock is applied to the switch
because of a leaf spring and steel ball in-
side. Please detect a signal by following
procedure.
1) Read access by a microcomputer
should be done every 30 msec. at 1mA
5VDC.
2) Two reading 'open' in succession
should be judged as 'open' condition.
3) After the judgement, if the 'open' condi-
tion continues for more than 0.5 sec., the
condition should be confirmed lastly.
<Example>
Microcomputer read access
5. Others
• Switch cover is set to the body through
O-ring for sealing purpose. Do not disas-
semble the switch or the characfteristics
may change.
• For switching of inductive loads (relay,
solenoids, buzzars, etc.), in order to pre-
vent damage to contacts due to the occur-
rence of arcing, an arc absorbing circuit
should be applied.
Tip SW
30ms
close
open
Judge
as
“open”
More than 0.5 sec.
confirm as “open”