NV175 Series 3" x 5" 175W Power Supplies 1-5 Outputs Up to 90% Efficient Active Power Factor Correction Universal Input (90 - 264VAC) No Minimum Loads Medical Approvals Key Market Segments & Applications Broadcast Test & Measurement Medical Industrial Computing and Routers Features and Benefits Feature High Efficiency Low Profile Power Factor Corrected No Minimum Loads Benefit Less heat dissipated in system Fits in 1U enclosures Supports Global Use Ease of Use Specifications MODEL ITEMS Input Voltage range Inrush Current A Power Factor Harmonics Line Regulation Load Regulation Cross Regulation Ripple & Noise mV Efficiency Minimum Load A Overcurrent Protection Overvoltage Protection V Overtemperature Protection Hold Up Time (Typ) ms Leakage Current (max) mA Remote Sense DC Good (Specify N option) Remote On/Off (Specify N option) Operating Temperature (1)(6) Storage Temperature Humidity (non condensing) Cooling Isolation Vibration (non operating) Shock Safety Agency Approvals Immunity Conducted Emissions and Flicker Radiated Emissions (2) Weight (Typ) Size (3) Warranty Notes: (1) -20C cold start g in yrs NV175 90 - 264VAC (47 - 63Hz, 440Hz with reduced PFC) <40A at 25C and 264VAC input, Cold Start EN61000-3-2 Compliant < 0.1% for 90-264VAC input change < 1% for 0-100% load change < 0.1% for 100% load change on any output 1% or 50mV (Which ever is greater) Up to 90%, configuration dependant None >105% CH1 & CH2, 120-130%, Cycle AC line to reset Yes >16ms at 90VAC Input 300A max at 264VAC, 63Hz (normal condition, 500A Single Fault Condition) On Outputs CH1 & CH2, 0.5V compensation maximum CH1 Only, High on Fail (<95% of nominal) TTL logic level high (or open circuit on -N3 option) will inhibit all outputs (except Standby) 0 to +70C. Derate linearily to 50% load from 50C to 70C -40 to +85C 5 - 95% RH Forced air, 2m/s from input to output Input to Ground 2.3kVDC, Input to Output 4.3kVDC, Output to Ground 200VDC 2G, 10-500Hz (sweep & endurance at resonance) in all 3 planes 30G per IEC68-2-27 UL60950-1, CSA22.2 No 60950-1, EN60950-1, IEC60950-1, CE for LVD, IEC60601-1, EN60601-1, EN61010-1, IEC61010-1 EN61000-6-2:2001, EN61000-4-2, -3, -4, -5, -6, -8, -11 EN55022 Class B (per CISPR.22), EN61000-3-3 EN55022 Class A (per CISPR.22) 250g 3" x 5" x 1.25"; N option version 3.7" x 5" x 1.25" (4" x 6.4" x 1.6" with fan) Three Years (2) See application note for Class B (3) Including underside component leads 3055 Del Sol Blvd * San Diego, CA 92154 * 1-800-LAMBDA-4 NV175 Series Stocked Models Quick Selector CH1 (4) Model CH2 (4) CH3 CH4 Outline Drawing CH5 Global Stand By Option (5) Type NV1-1T000 12V/15A NV1-1G000 24V/7.5A NV1-453TT +5V/25A +3.3V/15A +12V/5A -12V/1A NV1-453FF +5V/25A +3.3V/15A +15V/5A -15V/1A NV1-4G5TT +24V/7.5A +5V/8A +12V/5A -12V/1A NV1-4G5FF +24V/7.5A +5V/8A +15V/5A -15V/1A NV1-453TT-N3 +5V/25A +3.3V/15A +12V/5A -12V/1A 5V/2A N3 (ATX) NV1-453FF-N3 +5V/25A +3.3V/15A +15V/5A -15V/1A 5V/2A N3 (ATX) NV1-4G5TT-N3 +24V/7.5A +5V/8A +12V/5A -12V/1A 5V/2A N3 (ATX) NV1-4G5FF-N3 +24V/7.5A +5V/8A +15V/5A -15V/1A 5V/2A N3 (ATX) Notes: (4) Maximum combined current from CH1 + CH2 = 25A 5V CH1 models are limited to 175W max. All others 180W (5) CH5 is always on regardless of inhbit status. Peak rated at 2.5A, floating output (6) Convection cooled maximum ratings: CH1: 55W, Ch2: 8.25W, Ch3: 9W, CH4: 3W, 75.25W total. 0C - 40C temperature range (7) 12 - 12.5V if CH3 is fitted. (8) 14.5 - 15.5V if CH3 is fitted. (9) 24 - 24.5V if CH2 is fitted. 24 - 26V if CH3 is fitted See the website for detailed datasheet and outline drawing. Built to Order Model Selector CH1 CH1(4) Adjust. Code Range +5V / 25A 5 +12V / 15A +15V / 12A +24V / 7.5A 5 - 5.5V CH2(4) +1.8V / 15A +2.7V / 15A +3.3V / 15A No output CH2 Code Adjust. Range 1 2 3 0 0.9 - 3.3V 2.5 - 3.3V 2.5 - 3.3V - T F 12 - 15V (7) 12 - 15V (8) +5V / 10A No output 5 0 3.3 - 5.5V - G 24 - 28V (9) +5V / 8A No output 5 0 3.3 - 5.5V - CH3 Code CH3 +12V / 5A +15V / 5A +24V / 2.5A No output T F G 0 Adjust. Range 12 - 15V 12 - 15V 18 - 24V - CH4 CH4 Code -12V / 1A -15V / 1A -3.3V / 2A -5V / 2A -12V / 2A -15V / 2A No output T F 3H 5H TH FH 0 Add "P" to code for positive polarity output Add "P" to code for positive polarity output Adjust. Range None None None None None None None How to Create a Model Number NV1- Enter number of outputs CH1 Code CH2 Code CH3 Code CH4 Code No Option AC Fail, Remote On/Off, 5V Standby, CH1 DC Good ATX AC Fail+Remote On/Off, 5V Standby, CH1 DC Good Global Option Case Option Blank N N3 Blank U C F No Case U Chassis U Chassis with Cover U Chassis, Cover and Fan* * A high output CH4 (3H, 5H, TH, or FH) must be selected to provide fan option. Example NV1 3 G 5 0 3HP N C Description: Triple output, 24V/7.5A, 5V/8A, 3.3V/2A, Global option N, U Chassis with cover. Mating Parts (Molex) Other Lambda Industrial Products CONN J1 J2 NV350 SC40/60 ZWS/ZWSPAF Housing 39-01-2245 09-50-8053 Pins 44476-3112 08-52-0113 350W 1U Modular Power Supply 1-6 outputs 40 to 80W single, dual & triple 3x5 footprint 5 to 240W single output power supplies For Additional Information, please visit www.lambdapower.com/products/nv-series.htm 3055 Del Sol Blvd * San Diego, CA 92154 * 1-800-LAMBDA-4 Revision B1: Oct 2005