General-outdoor MU150HxxxAQ_CP Series DWG NO. : MSSD-XXXX A0 LED DRIVER SPECIFICATIONS Customer's Part Number MOONS' Part Number MU150HxxxAQ_CP Series Model P/N CUSTOMER'S APPROVAL STAMP Please sign back after your approval. The specifications will come into force when we receive purchase order. DWG CHK STANDARD APPD. Page 1 of 7 subject to change without notice SHANGHAI MOONS' AUTOMATION CONTROL CO., LTD. Add: No.168, Mingjia Road, Shanghai 201107, P.R.China Tel: +86 (0)21 52634688 Website: www.moons.com.cn General-outdoor MU150HxxxAQ_CP Series DWG NO. : MSSD-XXXX Rev. A0 Date 2016/8/8 Contents new released ECO NO. DWG YangZhi CHK Bilin Tu A0 APPR Bilin Tu Page 2 of 7 subject to change without notice SHANGHAI MOONS' AUTOMATION CONTROL CO., LTD. Add: No.168, Mingjia Road, Shanghai 201107, P.R.China Tel: +86 (0)21 52634688 Website: www.moons.com.cn MU150HxxxAQ_CP Series General-outdoor DWG NO. : MSSD-XXXX A0 * Input voltage: 90-305Vac *Built-in active PFC function 0.98 Typ. * High efficiency: up to 93% Typ. * Built-in Lightning protection *Three dimming in one operation modes(0-10V Dimming / Clock Dimming(CLK)/PWM Dimming) *Protection: OVP, SCP, OTP *Full Power at 65%Iomax100%Iomax (Constant Power) *IP67 design for indoor or outdoor installations *UL Type TL, Type HL Features Version: A0 Specification Model (MU150HXXXAQ_CP ) 080 Efficiency(120Vac)(Typ.)Note.1 Efficiency(230Vac)(Typ.)Note.1 Voltage Range (V)Note.2 Voltage Rate (V)Note.2 Frequency Range (Hz) Input Power Factor(Typ.) THD(Typ.) AC Current(Typ.) Inrush Current(Max.) Leakage Current(Max.) Rated Output Voltage (V) Voltage range (V) Note. 4: Rated Current(mA) Output Current Range(mA) Output Current Set Range Constant Power Output Set Range Ripple&Noise Current ( Typ.) Current Tolerance (Imax) Line Regulation (Imax) Load Regulation (Imax) Turn on delay Time 12Vdc Output Voltage (Vdc) 12Vdc Output Current(Vdc) Dimming Control 0~10V/DMI+ Voltage 0~10V/DMI+ Short Current DIMMING FUNCTION Output Over Voltage(V) Environment Safety & EMC Others 150 210 300 420 600 90.0% 89.0% 89.0% 88.0% 88.0% 87.0% 93.0% 92.0% 92.0% 91.0% 91.0% 90.0% 90305Vac, OR 127~ 430Vdc (Derating may be need under low inputs, Refer to 'Derating Curve' ) 100Vac-277Vac 47~63 >0.95 with100% load,at 100Vac-277Vac 0.90(Typ.) with 70%~100% load,at 100Vac-277Vac/60Hz <15% at 220VAC input 50Hz,80%~100% load <20% at 100Vac-277Vac/60Hz input ,60%~100% load 1.8A at 100VAC input, 0.9A at 230VAC 65A at 230Vac input 25 Cold Start ( time wide=500uS, measured at 50% Ipeak,Not applicable for the inrush current to Noise Filter for less than 0.2ms) 0.75mA at 277VAC/60Hz input 283-188 214-142 150-100 107-71 75-50 54-36 38-25 283-113 214-86 150-60 107-43 75-30 54-21 38-15 530-800 700-1050 1000-1500 1400-2100 2000-3000 2800-4200 4000-6000 53-800 70-1050 100-1500 140-2100 200-3000 280-4200 400-6000 150(max) Rated Power (W) Protection 105 90.0% 93.0% Short Circuit Over Temperature Operating Temp. Operating Humidity Tc Storage Temp., Humidity Temp. Coefficient Vibration Safety Standard Withstand Voltage Isolation Resistance EMC Emission 6.5%Io_max100%Io_max 65%Io_max100%Io_max 10% max. ((PK-AV) /AV) with LED default mode and full load) 5% 3% 5% <1.2s, at 120Vac; <1s, at 277Vac 10.8Vmin.~13.2Vmax. 0mA~20mA max. Absolute maximum voltage -10Vmin~20Vmax 280uA~450uA (DIM(+)=0) Default is 0-10V dimming mode.others dimming ways like PWM/CLK Dimming can set by software configuration 350 290 200 145 100 73 52 No damage.The power supply shall be self-recovery when the fault is removed. Protection type: Constant current limiting. Decreases output current,returning to normal after over temperature is removed.. -40~+70( Refer to 'Derating Curve' ) 20~95%RH, non-condensing 90 max -40~+8510-95%RH 0.03%/0~50 10-500Hz,5G 12min/cycleperiod for 72min each along XYZ axes UL8750, UL1012, EN61347-1, EN61347-2-13 ,EN60598-1,EN62384 I/P-O/P:3.75KVAC I/P-FG:1.875KV O/P-FG:1.5KV I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500Vdc/25/70%RH EN55015/FCC Part 15 Class BEN61000-3-2 Class CEN61000-3-3 EMC Immunity EN61000-4-2,3,4,5,6,8,11Surge L,N-FG 10KV,L-N 10KV,EN61547 MTBF Lifetime(option) Dimension Weight 300,000 Hours,measured at full load,25 ambient temperature 50,000 Hours at Tc 75 (Refer to"Life Time VS. Tcase (Ref.)") or 50,000 Hours at Tc 85 221 x 67.5 x 40 mmLxWxH 1.1kg(Typ.) Note.1: Measured at full load and steady-state temperature in 25 ambient(Efficiency will be about 2% lower if measured immediately after startup ); Note. 2: Derating may be needed under low input voltages , Please Refer to 'Derating Curve' ; Note. 3: All parameters NOT specially mentioned are measured at 230VAC input , rated load and 25 of ambient temperature ; Note. 4: refer to V/I curve subject to change without notice Page 3of 7 SHANGHAI MOONS' AUTOMATION CONTROL CO., LTD. Add: No.168, Mingjia Road, Minbei Industrial Park, Shanghai 201107, P.R.China Tel: +86 (0)21 52634688 Website: www.moons.com.cn MU150HxxxAQ_CP Series General-outdoor DWG NO. : MSSD-XXXXA0 Operating Curve Derating Curve V/I Curve Lifetime vs. Case Temperature Power Factor Curve Efficiency VS. Load Curve1050mA Typ. THD Curve subject to change without notice SHANGHAI MOONS' AUTOMATION CONTROL CO., LTD. Add: No.168, Mingjia Road, Minbei Industrial Park, Shanghai 201107, P.R.China Tel: +86 (0)21 52634688 Website: www.moons.com.cn Page 4of 7 MU150HxxxAQ_CP Series General-outdoor DWG NO. : MSSD-XXXX A0 Instruction 1.Field Programmable Topology Programmable Diver cable Programmer USB cable The programmable driver can be programmed by using special PC software and the programmer module. 2.Dimming Interface Description Pin description Pin 1 2 3 Name Vaux 12V Dim+/Program Dim- Value 10.8V-13.2V 0-10V 0V Description Passive dimmers power supply Dimming/Programming input DC Ground 3.Dimming Software Function Instruction n Adjustable Output Current(AOC) n Adjustable Startup Time(AST) n Fade Time(FT) PWM Input a PWM signal from the 2nd pin(Dim+/Program) of the dimming interface to change the output current.User can set "Positive Logic" or " Negative Logic" of the PWM signal. PWM duty circle: 1%~99%(it has both positive and negative logics ), frequency: 500Hz~5kHz, 3V~10V is high,-0.3V~0.8V is low. Users can set the rated current between 7%*Max Current and 100%*Max Current Set driver's "Start Fade up Time". It means how much time the driver costs to achieve the "Module Current " that the user set. The valid value is 0s, 1s, 2s, 5s, 10s, 20s, 40s. Set driver's "Fade up Time". This function is available in the Smart Midnight ClockDIM and Fixed ClockDIM mode; It means how much time the driver costs to achieve another dimming level from previous dimming level. The valid value is 0s, 1s, 2s, 5s, 10s, 20s, 40s. n 1-10V Allow users to set the max and min output current and corresponding output voltage to clarify the 1-10V dimming curve. Input a 0~10V signal from 2nd pin of the dimming interface. Default: input 1V, output current 10%; input 8.5V, output current 100%. subject to change without notice Page 5 of 7 SHANGHAI MOONS' AUTOMATION CONTROL CO., LTD. Add: No.168, Mingjia Road, Shanghai 201107, P.R.China Tel: +86 (0)21 52634688 Website: www.moons.com.cn MU150HxxxAQ_CP Series General-outdoor DWG NO. : MSSD-XXXX Instruction n Smart Midnight ClockDIM n Fixed ClockDIM Smart Midnight ClockDIM allows dimming to predefined light levels based on the nightly operating time. With flexibility in setting time and light levels, the user can configure the driver for specific locations and application needs. Using Smart Midnight ClockDIM, it is possible to set up to 5 dim levels and time intervals. The driver does not have a real time clock. Instead it runs a virtual clock, determined by the length of nightly operating hours. After 3 ON-OFF cycles, the driver will calculate the virtual clock time. A valid ON-time is defined as a period during which the driver operates continuously for 4 hours to 24 hours. For example, if the requirement in summer is: 23:00-00:00: 75%, 00:00-04:00: 50%, 04:00-05:00: 75% (other time 100% or Off). The driver should be powered on for 7h, so it can calculate the virtual clock time as 22:00. Then we can set the dimming plan: 22:00~23:00: 100%, 23:00-00:00: 75%, 00:00-04:00: 50%, 04:00-05:00: 75%. From summer to winter, the valid ON-time changes day by day. The driver should be powered on for 17h in winter, and it also can calculate the virtual clock time as 17:00. Then the dimming plan is 17:00~23:00: 100%, 23:00-00:00: 75%, 00:0004:00: 50%, 04:00-05:00: 75%, 05:00~10:00: 100%. From the above, if we set the dimming plan as shown in the picture, after repeating the driver ON-time for 3 consecutive days, the dimming plan takes effect from the 4th day onwards. Each day the driver powered on, it has a different start time according to the virtual clock time. So the driver can satisfy different requirements for different seasons. Allow users to separate 24hrs into 5 sections and corresponding output current. n Constant Light Output(CLO) n No Dimming The driver will be in constant output mode. n Set MODULE Working hrs(SMW) User can check how much time the driver works through this function. Traditional light sources suffer from depreciation in light output over time. This applies to LED light sources as well. The CLO feature enables LED solutions to deliver constant lumen output through the life of the light engine. Based on the type of LEDs used, heat sinking and driver current, it is possible to estimate the depreciation of light output for specific LEDs and this information can be entered into the driver. The driver counts the number of light source working hours and will increase output current based on this input to enable CLO. When the CLO feature is enabled, the driver nominal output current will be defined by the CLO percentage as shown by the equation below: Driver target nominal output current = CLO percentage * AOC. For example, in the CLO profile shown in Figure, between 52,000-60,000 working hours, the CLO percentage is set at 98%. Assuming the nominal AOC is set to 500mA, the driver output current with CLO enabled will be 0.98 x 500 = 600 mA. The CLO percentage can be set to a value between 85%-100%, in increments of 1%. The LED module working hours can be set at any value between (0100,000 hours). subject to change without notice Page 6 of 7 SHANGHAI MOONS' AUTOMATION CONTROL CO., LTD. Add: No.168, Mingjia Road, Shanghai 201107, P.R.China Tel: +86 (0)21 52634688 Website: www.moons.com.cn A0 MU150HxxxAQ_CP Series General-outdoor DWG NO. : MSSD-XXXXA0 Mechanical Specification Dimensions(Unit:mm) RoHS Compliance: Our products comply with the European Directive 2002/95/EC, calling for the elimination of lead and other hazardous substances from electronic products. subject to change without notice SHANGHAI MOONS' AUTOMATION CONTROL CO., LTD. Add: No.168, Mingjia Road, Minbei Industrial Park, Shanghai 201107, P.R.China Tel: +86 (0)21 52634688 Website: www.moons.com.cn Page 7of 7