Digital Multi Meter
70
Digital Multimeter
O
scilloscope
s
D
igi
tal Powe
r
A
na
l
yzer
s
G
enerators
,
S
ources,
Manometers etc
.
O
ptical Measurin
g
I
n
s
tr
u
m
e
nt
s
Calibrato
r
Data Lo
gg
e
r
C
lamp-o
n
Po
w
e
r
Me
t
er
Digital Multimeter
Digi
ta
l
M
u
l
t
i
mete
r
Digital Multimeter
Clamp-on Teste
r
nsulat
on Teste
Earth Tester
,
O
th
e
r Pr
oduc
t
s
T
hermomete
r
rec
s
o
M
easurin
g
Instrument
s
Meters Product
s
7533series
7534series
3.5 Digits4.5 Digits
TY720
TY710
TY530
TY520
73201
73202
73203
73101
Existing
model
Discontinued products
for replacing
73401
73101
753201
753202
753203
753701
753702
753703
753704
753801
73303
73302
73301
754401
754402
73402
Handheld Digital Multi Meter Sellection
Simple selection for replacing discontinued products
Handhel Digital Multi Meter Models
Function item TY710 TY720 TY520 TY530 73201 73202 73203 73204 73101
Measurment Function Ture RMS Ture RMS MEAN
Sellect RMS RMS MEAN
Sellect MEAN MEAN MEAN MEAN MEAN
Max. Measurrement Accuracy at DCV 0.02% 0.09% 0.5% 0.5% 0.3% 0.5% 0.7%
Wide bandwidth 20KHz 100KHz 1kHz
Display Digits(Uint:Digit) 5 digits 3.5 Digits 3.5 Digits 3.5 Digits
Max. Value 50000 6000 4300 4300
Bar Graph Dsiplay (Uints:Segment) 51 31 32
LCD Back Light White LED LED
Max.Measurement Voltage (AC/or DC)
50.000mV
to
1000.0V
50.000mV
to
1000.0V
600.0mV
to
1000V
600.0mV
to
1000V
4.000V*3
to
600V
4.000V*3
to
600V
4.000V*3
to
600V
4.000V*3
to
600V
4.000V*3
to
600V
Max.Measurement Currents (AC/or DC)
500.00µA
to
10.000A
500.00µA
to
10.000A
600.0µA
to
10.00A
600.0µA
to
10.00A
400.0µA
to
10.00A
400.0µA
to
10.00A
400.0µA
to
10.00A
——
Max.Measurement Resistance
500.00
to
50.000M
500.00
to
50.000M
600.0
to
60.00M
600.0
to
60.00M
400.0
to
40.00M
400.0
to
40.00M
400.0
to
40.00M
400.0
to
40.00M
400.0
to
40.00M
Max.Measurement Frequency
2.000Hz
to
99.99kHz
2.000Hz
to
99.99kHz
10.00Hz
to
99.99kHz
10.00Hz
to
99.99kHz
—————
Max.Measurement Capcitance
5.000nF
to
50.00mF
5.000nF
to
50.00mF
10.00nF
to
1000µF
10.00nF
to
1000µF
20.00nF
to
200.0µF
20.00nF
to
200.0µF
——
Max.Measurement Temperature +1372°C*1+1372°C*1+600°C*1+600°C*1—————
Duty Ratio (%) Measuement 쏹쏹———————
Low-Power — ———————
AC+DC Measurement 쏹쏹———————
Max./Min./Ave. Value Memory 쏹쏹—————
Diode Test 쏹쏹쏹쏹쏹쏹쏹쏹쏹
Continuity Check 쏹쏹쏹쏹쏹쏹쏹쏹쏹
Relative/Percentage (%) calculation 쏹쏹쏹쏹—————
Decibel calculation 쏹쏹 ——————
Selection Auto range or Manual range 쏹쏹쏹쏹쏹쏹쏹쏹
Peak Hold ———————
Data Hold *2쏹쏹쏹쏹쏹쏹쏹쏹
Auto Hold 쏹쏹쏹쏹쏹쏹쏹쏹
Communication for PC *2*2*2—————
Data Logging Memory *2*2*2—————
Data Memory 1000 10000 1600
Operating Temp. and Humidity -20 to 55°C -20 to 55°C -10 to 55°C -10 to 55°C 0 to 50°C 0 to 50°C 0 to 50°C 0 to 50°C 0 to 50°C
Electric Safety 1000V CAT III CAT III
Electric Safety 600V CAT IV CAT IV CAT II CAT III CAT III
Electric Safety 300V CAT III CAT II
*1 Temperature probe is necessary when measuring temperature.
*2 The communications package (model: 92015) for DMM is necessary when connecting it with PC.
*3 73101,732Series minimum range of DCvoltage is 400. 0 mVDC.
Digital Multi Meter
71
Digital Multimeter
O
scillosco
p
e
s
D
igi
tal Powe
r
A
na
l
yzer
s
G
enerators
,
S
ources,
Ma
n
o
m
e
t
e
r
s
e
t
c.
O
ptical Measurin
g
I
n
s
tr
u
m
e
nt
s
Ca
li
b
r
a
t
or
D
ata
L
ogge
r
C
lamp-o
n
Po
w
e
r
Me
t
er
Digital Multimeter
Digit
a
l
M
u
lti
me
t
e
r
Digital Multimeter
Clam
p
-on Teste
r
I
n
su
l
a
ti
o
n T
es
t
er
Earth Tester
,
O
th
e
r Pr
oduc
t
s
The
rm
o
m
e
t
er
P
r
ec
i
s
i
on
M
easur
i
n
g
I
n
s
tr
u
m
e
nt
s
Me
t
e
r
s
P
r
oduc
t
s
A New De Facto Standard for Handheld DMM
TY700 Series
Digital Multimeters
Maximum Measurement Accuracy: 0.020% rdg + 2 dgt
Highly Reliable: Closed case calibration
Full Support of Data Management: Measured data stored in internal memory
Safe Design: Shutters prevent erroneous insertion of test leads into current measurement-
terminals (terminal shutters)
Shockproof elastomer casing
•Wide operating temperature range: -20 °C to 55°C
General Specifi cations
Additional Functions USB communication (optional adapter & software),
data memory (TY720: 10,000 data, TY710: 1,000 data), max/min
value memory, relative/percentage value computation, logarithm
computation, data/auto hold, peak hold (TY720), overvoltage
warning, backlight
Power Supply Four AA (R6) dry cells
Battery Life Approx. 120 hours
Dimensions 90 (W) × 192 (H) × 49 (D) mm
Weight Approximately 560 g (including batteries)
Safety Standards 1000 V CAT. 3, 600 V CAT. 4
Features
Data saved in the internal memory PC transfer is possible (Save memories or Logging Memories)
DMM measurements show in real time monitor display is possible.
Large amounts of data not covered by the internal memory PC communication
with data transfer is possible. At the same time Excel transferable is also.
Maximum incoming data: 32767
Measurement data to Excel direct deployment is possible. Automatically creates a chart sheet.
DMM of dedicated application software (Model: 92015 )
DMM’s and you can easily manage the data in memory. Is also capable of real-time communications
92015 product specifi cation:
Communication cable
Communications cable: infrared communication adapter +
communications cable (USB specifi -
cations) 2 m length
Interface standards: USB specifi cation conforms to the 1.1
Available models : TY710 , TY720 , TY530
Application software
Operating environment of the personal computer
OS: Windows XP / Vista / 7
CPU: Pentium 133 MHz or higher
Memory: 64 MB
Hard disk has free space or more storage:
10 MB Over, CD drive
Excel: since the Excel2000
Software: CD, communication cable (including adapter),
User’s manual
TY710 TY720
Detection RMS Switching detection (RMS or MEAN)
Item Range Accuracy
DCV
50mV 0.05+10
500mV/2400mV 0.02+2
5V 0.025+5
50V/500V/1000V 0.03+2
ACV
[RMS]
Upper: 10 to 20Hz
Lower: 20Hz to 1kHz
Upper: 1kHz to 10kHz
Lower: 10kHz to 20kHz
Upper: 20kHz to 50kHz
Lower: 50kHz to 100kHz
Upper: 10 to 20Hz
Lower: 20Hz to 1kHz
Upper: 1kHz to 10kHz
Lower: 10kHz to 20kHz
Upper: 20kHz to 50kHz
Lower: 50kHz to 100kHz
50mV
2+80
0.4+40
5+40
5.5+40
15+40
15+40
50mV/5V/
50V/500V 1.5+30
0.7+30
0.7+30
2+50
1+30
0.4+30
0.4+30
1+40
2+70
5+200
1000V 3+30
3+30
ACV
[MEAN]
10 to 20Hz 20Hz to 500Hz 500Hz to 1kHz
50mV 4+80 1.5+30 5+30
50mV/5V/
50V/500V/1000V 2+30 1+30 3+30
DCV+ACV
Upper: DC,10 to 20Hz
Lower: DC,20Hz to 1kHz
Upper: DC,1kHz to 10kHz
Lower: DC,10kHz to 20kHz
Upper: DC,20kHz to 50kHz
Lower: DC,50kHz to 100kHz
Upper: DC,10 to 20Hz
Lower: DC,20Hz to 1kHz
Upper: DC,1kHz to 10kHz
Lower: DC,10kHz to 20kHz
Upper: DC,20kHz to 50kHz
Lower: DC,50kHz to 100kHz
5V/50V/500V 1.5+10
1+10
1+10
2+10
1.5+10
0.5+10
0.5+10
1+10
2+10
5+20
1000V 1.5+10
1+10
1.5+10
0.5+10
DCA
500µA/5000µA/
50mA/500mA 0.2+5
5A 0.6+10
10A 0.6+5
ACA
[RMS]
10Hz to 20Hz 20Hz to 1kHz 1kHz to 5kHz 10Hz to 20Hz 20Hz to 1kHz 1kHz to 5kHz
500µA/5000µA/
50mA/500mA 1.5+20 1+20 1+20 0.75+20 1+30
5A/10A 1.5+20 1+20 2+30
ACA
[MEAN]
10Hz to 20Hz 20Hz to 1kHz 1kHz to 5kHz
500µA/5000µA/
50mA/500mA 2+20 1.5+20 2+30
5A/10A 3+20 2+20 4+30
DCA+ACA
DC,10 to 20Hz DC,20Hz to 1kHz DC,1kHz to 5kHz DC,10 to 20Hz DC,20Hz to 1kHz DC,1kHz to 5kHz
500µA/5000µA/
50mA/500mA 2+10 1.5+10 1.5+10 1+10 1.5+10
5A/10A 2+10 1.5+10 3+10
Resistance
500/5k/50k
500k0.1+2 0.05+2
5M0.5+2
50M1+2
Low-power
Resistance
5k/50k/500k0.2+3
5M1+3
Frequency 2.0Hz to 99.99kHz 0.02+1
Capacitance
5nF/50nF/500nF
5µF/50µF 1+5
500µF 2+5
5mF/50mF 3+5
Continuity check 550Buzzer sounds at 100±50 or less
Diode test 2.4V 1+2
Temperature -200 to 1372°C 1+1.5°C
Digital Multi Meter
72
Digital Multimeter
O
scilloscope
s
D
igi
tal Powe
r
A
na
l
yzer
s
G
enerators
,
S
ources,
Manometers etc
.
O
ptical Measurin
g
I
n
s
tr
u
m
e
nt
s
Calibrato
r
Data Lo
gg
e
r
C
lamp-o
n
Po
w
e
r
Me
t
er
Digital Multimeter
Digi
ta
l
M
u
l
t
i
mete
r
Digital Multimeter
Clamp-on Teste
r
nsulat
on Teste
Earth Tester
,
O
th
e
r Pr
oduc
t
s
T
hermomete
r
rec
s
o
M
easurin
g
Instrument
s
Meters Product
s
73101
Pocket Digital Multimeter
4300 count display
Continuity Check and Diode Test
Auto Hold
Auto Power Off
73101 Specifi cations
Accuracy: (23°C ±5°C, Less than 80% RH), ±(% rdg + dgt)
Pocket DMM with Superb Portability
732 Series
Digital Multimeters
3.5 digits (4,300-count), Mean val ue type
Measurement Functions: Voltage, Current, Resistance, Con-
tinuity Check, Diode Test, Capacitance
Features: Auto hold, Auto power-off
Low-cost Handheld DMM
Provides Safety Levels Demanded in Field Work
Model 73201 732027320373204
Detection Mean value
Item Range Accuracy
DCV 400.0 mV/4.000 V/
40.00 V/400.0 V/600 V
0.5%+1
0.75%+1 0.5%+1 0.3%+1 0.5%+1
ACV 4.000 V/40.00 V/
400.0 V/600 V 1.0%+5 0.75 %+ 5
DCA
400.0 µA/4000 µA/
40.00 mA/400.0 mA/
10.00 A
1.0%+2
2.0%+2
ACA
(40 to 500 Hz)
400.0 µA/4000 µA/
40.00 mA/400.0 mA/
10.00 A
2.0%+20
2.0%+5
2.0%+20
2.0%+5
2.0%+20
Resistance
400.0 /4.000 k/
40.00 k/400.0 k/
4.000 M/40.00 M
0.75%+2
0.75%+1
2.0%+1
5.0%+2
Item Range Accuracy Input Resistance
DCV
400.0 mV
4.000 V
40.00/400.0/600 V
1.2%+2
0.7%+1
1.2%+1
>100 M
11 M
10 M
ACV 4.000 V
40.00/400.0/600 V 2.0%+5 10 M
Resistance
400.0
4.000 k/40.00 k/400.0 k
4.000 M
40.00 M
1.2%+2
2.0%+3
5.0%+3
Continuity check 400.0
Diode test 2.00 V 1.5%+1 Open-circuit Voltage<3.4 V
Tes t ing Curr ent <1.0 mA
General Specifi cations
• External dimensions:
74 (W) × 155 (H) × 31 (D) mm
• Weight: Approx. 240 g
• Power Supply:
Two AAA (LR03 or R03) dry cells
732 Series Specifi cations
Accuracy: (23°C ±5°C, Less than 80% RH), ±(% rdg + dgt)
Genetal Specifi cations
• External dimensions:
76 (W) × 117 (H) × 18 (D) mm
• Weight : Approx. 110 g
• Power Supply: Two LR-44 dry cells
TY500 Series
Digital Multimeters
3.5 digits (6,000-count, 31-segment bar graph display),
RMS type
Measurement Func tions: Voltage, Cur rent, Re sis tance,
Con ti nu ity Check, Diode Test, Frequency, Ca pac i tance,
Temperature
Features: Closed case calibration, Hi-impact overmold case,
USB communication (optional adapter & software) (TY530
only), data memory (1,600 data for TY530 only)
Safety Standards: 1000 V CAT. 3, 600 V CAT. 4
General Specifi cations
• External dimensions:
90 (W) × 192 (H) × 49 (D) mm
• Weight : Approx. 570 g
• Power Supply: Four AA (R6) dry cells
TY500 Series Specifi cations
Accuracy: (23°C ±5°C, Less than 80% RH), ±(% rdg + dgt)
TY520 TY530
Detection RMS Switching detection (RMS or MEAN)
Item Range Accuracy
DCV
600mV/6V/
60V/600V 0.09 + 2
1000V 0.15 + 2
ACV
50/60Hz 40 to 500Hz500Hz to 1kHz
600mV/6V/60V/600V
1000V 0.5 + 5 1 + 5 1.5 + 5
DCA 600µA/6000µA/60mA 0.2 + 2
600mA/6A/10A 0.5 + 5
ACA
50/60Hz 40Hz to 1kHz
600µA/6000µA/60mA/
600mA/6A/10A 0.75 + 5 1.5 + 5
Resistance
600/6k/60k/600k0.4 + 1
6M0.5 + 1
60M1 + 2 (0 to 40M)
2 + 2 (40 to 60M)
Frequency 10.0Hz to 99.99kHz 0.02 + 1
Capacitance
10nF 2 + 10
100nF /F/10µF 2 + 5
100µF /100F 3 + 5
Continuity check 600Buzzer sounds at 50±30 or less
Diode test 2V 1 + 2
Temp e r a t ur e -50 t o 60 0 ° C 2 + 2 °C
Digital Multi Meter
73
Digital Multimeter
O
scillosco
p
e
s
D
igi
tal Powe
r
A
na
l
yzer
s
G
enerators
,
S
ources,
Ma
n
o
m
e
t
e
r
s
e
t
c.
O
ptical Measurin
g
I
n
s
tr
u
m
e
nt
s
Ca
li
b
r
a
t
or
D
ata
L
ogge
r
C
lamp-o
n
Po
w
e
r
Me
t
er
Digital Multimeter
Digit
a
l
M
u
lti
me
t
e
r
Digital Multimeter
Clam
p
-on Teste
r
I
n
su
l
a
ti
o
n T
es
t
er
Earth Tester
,
O
th
e
r Pr
oduc
t
s
The
rm
o
m
e
t
er
P
r
ec
i
s
i
on
M
easur
i
n
g
I
n
s
tr
u
m
e
nt
s
Me
t
e
r
s
P
r
oduc
t
s
93029
RD031
323
110 50
10
1200
50
3.2
22
14
90050
200
50
10
1200
1.6
22
14
150
273
110
90051
50
26
14
30 110
178
6
50
10
1200
15
6.0
14
90055 50
13.5
177.5
30 110 50 10
25.5
5.5
1200
15
6.0
14
90056
96095
9807392015
Specifi cations
96095Model
12mm
AC10mV/A(AC 113 0 0mVrms)
50/60Hz
1.2%+0.4mV
-30
to
70
°C relative Humidity 85% or
less (no condensation)
Low battery warning 2.2V±0.2V or less red LED flash
1.9V±0.2V or less Power off
Approx. 35Hours till a low battery indicator flashes
*1
Dimensions&Weight 127 (L) × 42 (W) × 22 (D) mm
Cord length: Approx.1200mm Weight: Approx 140g
EN61010-1CAT3Pollution degree2, Altitude 2000m or less for indoor use
EN61326-1ClassB,EN61326-2-032
*1 From low battery warning to power off is about 5hours
 
Conductor Size
Measurement range
AC 0.1 to 130A
DC 0 to ±180A
General specifications
Output voltage Accuracy (at 23°C±5°C)
Operating Temp&Humidity range
Storage Temp&Humidity range
Power source
DC3V(Size AAA alkaline Battery LR03 × 2pcs)
Continuous use
Applicable standards
Accessories Soft case(94030),Battery,User’s Manual
-10
to
55
°C relative Humidity 85% or
less (no condensation)
2.5%+0.4mV
40Hz to 1kHz
1.2%+0.4mV
DC10mV/A (DC 0±180 0mV)
96095
AD/DC Clamp-on Probe
Light and compact, easy to carry and easy to clamp on
crowded wirings.
Expands measuring span of currents and assure safety
when measuring with any kind of DMM.
96001
Standerd Accessories
Applicable DMM Models
TY700 TY500 732
Name Model Specifi cation TY710 TY720 TY520 TY530 01 02 03 04
Communication Package for
Digital Multimeters 92015 Communication Adapter for USB+cable+Application Software 쏹쏹
Test leads with Alligator Clip 99014 1000V CAT# 600V CAT$
Red/Black(1set) 쏹쏹
Alligator Clips B9646HF Red/Black(1set) 쏹쏹쏹쏹쏹쏹쏹
Rubber Case 93007 쏹쏹쏹쏹
Carrying Case 93029 Hard case 쏹쏹쏹쏹
B9646GB Hard case 쏹쏹쏹쏹쏹쏹쏹
Temperature Probe
(Thermocouple type K)
(Banana plag output)
90050 -50 to 150°C for liquld 쏹쏹쏹쏹
90051 -50 to 600°C for liquld 쏹쏹쏹쏹
90055 -20 to 250°C for surface 쏹쏹쏹쏹
90056 -20 to 500°C for surface 쏹쏹쏹쏹
Currents Clamp-on probe 96001 For 400AAC Output:AC10mV/A*1쏹쏹쏹쏹쏹쏹쏹
96095 For 130AAC/180ADC
Output: AC10mV/A or DC10mV/A*2쏹쏹쏹쏹쏹쏹쏹
Applicable DMM Models
TY700 TY500 732
Name Model Specifi cation TY710 TY720 TY520 TY530 01 02 03 04
Test leads 98073 1000V CAT# 600V CAT $ Red/Black(1set) 쏹쏹쏹쏹
RD031 L-plug,Red/Black(1set) 쏹쏹쏹
Fuse 99015 440mA/1000V 쏹쏹쏹쏹
99016 10A/1000V 쏹쏹쏹쏹
F02 15A/250V 쏹쏹쏹쏹
F05 500mA/250V 쏹쏹쏹쏹
Accessorise
*1 Please use it with the ACV range. It is necessary to read the indicated value in a different way as TY710 and the TY720,732 series. The example: In AC1V display = 100A TY520 and TY530, it is possible
to scale it. (Even 60A or less display is possible in case of 96001. )
*2 Please use it with ACV or DCV range. It is necessary to read the indicated value in a different way as TY710 and the TY720,732 series. The example: In AC1V display = 100A TY520 and TY530, it is
possible to scale it. (Even 60A or less display is possible in case of 96095. )
DMM Accessories