Additional Resources: Product Page | 3D Model date 07/09/2020 page 1 of 3 SERIES: MD-SP DESCRIPTION: MINI DIN CONNECTOR FEATURES * vertical * panel mount * plastic mounting ears w/recess for hex nut RoHS PART NUMBER KEY MD - XX SP Base Number Pin Options 30 = 3 pins 40 = 4 pins 50 = 5 pins 60 = 6 pins 70 = 7 pins 80 = 8 pins SPECIFICATIONS parameter conditions/description min max 100 12 rated input voltage rated input current typ at 100 Vac at 12 Vdc contact resistance insulation resistance at 250 Vdc voltage withstand for 1 minute operating temperature life RoHS yes A A 30 m cuidevices.com 250 Vac 4.5 kg 0.9 3 kg 5 80 C 5,000 UL94V-0 1 2 M insertion force flammability rating Vac Vdc 50 withdrawal force units cycles Additional Resources: Product Page | 3D Model CUI Devices SERIES: MD-SP DESCRIPTION: MINI DIN CONNECTOR date 07/09/2020 page 2 of 3 MECHANICAL DRAWINGS units: mm[inches] TOLERANCE: 0.2mm MD-30SP MD-40SP 2 2 4 1 3 3 1 MD-60SP 4 2 1 3 6 5 4 3 silver shell brass nickel body HIPS (PH-88) housing NY6+FB (PA-1010C2) MD-50SP 5 4 2 3 MD-80SP 7 6 1 PLATING phosphor bronze 1 MD-70SP 2 MATERIAL pins 5 cuidevices.com 2 1 5 8 4 7 3 6 Additional Resources: Product Page CUI Devices SERIES: MD-SP DESCRIPTION: MINI DIN CONNECTOR | 3D Model date 07/09/2020 page 3 of 3 REVISION HISTORY rev. description date 1.0 initial release 02/23/2006 1.01 new template applied 02/09/2012 1.02 updated datasheet 08/25/2017 1.03 brand update 02/19/2020 changed housing mold 07/09/2020 1.04 The revision history provided is for informational purposes only and is believed to be accurate. CUI Devices offers a one (1) year limited warranty. Complete warranty information is listed on our website. CUI Devices reserves the right to make changes to the product at any time without notice. Information provided by CUI Devices is believed to be accurate and reliable. However, no responsibility is assumed by CUI Devices for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI Devices products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness. cuidevices.com