Cooper Bussmann(R)(R) Bussmann NH DIN Dual Indication Fuse Links NH With Insulated Metal Gripping Lugs Class of Operation gL/gG, 400V AC, 2 to 630 Amps Sizes 000 to 3 Standards/ Approvals: CATALOGUE SYMBOL: (amp)NHG(Size)BI-400 HRC FUSE LINKS CLASS OF OPERATION gL/gG 400V AC 2 to 630 AMPS SIZES 000 to 3 Dimensional Data IEC 60269, VDE0636, DIN 43 620 Part 1 to 4. Description: A square bodied range of industrial fuse links for a wide variety of applications. Packaging: All fuse links are packed in 3's. Technical Data: Rated Voltage: Rated Breaking Capcity: Rated Frequency: Operating Frequency: Design -Insulator: -Metal Parts: 400V AC 120kA 50Hz 45-62 Hz Steatite Corrosion-proof (aluminium) Contact Blade: Full contact blades, Silver plated copper Environmental: 100% recyclable Cadmium & lead free for sizes 000 to 3 (2A to 630A) Size a a1 a2 (max) a3 a4 b (nom) c1( 8) c2 (nom) D (nom) e1 (max) e2 (max) e3 (max) e4 (nom) f (max) 000 78.5 1.5 54 45 1.5 49 1.5 15 35 10 2 0.5 41 21 21 6 8 00 78.5 1.5 54 45 1.5 49 1.5 15 35 10 2 0.5 48 30 25 6 15 01 135 2.5 75 62 2.5 68 2.5 15 40 11 2.5 0.5 48 30 25 6 15 1 135 2.5 75 62 2.5 68 2.5 20 40 11 2.5 0.5 53 52 25 6 15 02 150 2.5 75 62 2.5 68 2.5 20 48 11 2.5 0.5 53 52 25 6 15 2 150 2.5 75 62 2.5 68 2.5 25 48 11 2.5 0.5 61 60 25 6 15 03 150 2.5 75 62 2.5 68 2.5 25 60 11 2.5 0.5 61 60 25 6 15 3 150 2.5 75 62 2.5 68 2.5 32 60 11 3 0.5 76 75 25 6 18 Form No. NH Page 1 of 7 Data sheet 720097 Cooper Bussmann(R)(R) Bussmann NH DIN Dual Indication Fuse Links NH Class of Operation gL/gG, 400V AC, 2 to 100 Amps Sizes 000 Time Current Characteristics for Size 000 Size 000 Details: Standards/Approvals: Rated Currents: IEC60269, DIN 43 620, VDE0636 2, 4, 6, 10, 16, 20, 25, 32, 35, 40, 50, 63, 80 & 100 Amps Part Number Amp Rating 2NHG000B-400 4NHG000B-400 6NHG000B-400 10NHG000B-400 16NHG000B-400 20NHG000B-400 25NHG000B-400 32NHG000B-400 35NHG000B-400 40NHG000B-400 50NHG000B-400 63NHG000B-400 80NHG000B-400 100NHG000B-400 2 4 6 10 16 20 25 32 35 40 50 63 80 100 I2t(Ampere 2 seconds) Minimum Pre-arcing 4 6 14 58 234 584 1000 2400 2900 4000 4000 6000 9900 18100 I1 120kA @ 400Vac 6 12 21 174 800 1800 2800 7200 8500 12300 13600 20400 35700 39800 Watts Loss 3.9 1.4 2.2 1.5 2.3 2.2 3.1 2.8 2.8 3.0 3.4 4.5 4.7 5.3 Net weight per fuse Rated Voltage Form No. NH Page 2 of 7 Data sheet 720099 Cooper Bussmann(R)(R) Bussmann NH DIN Dual Indication Fuse Links NH Class of Operation gL/gG, 400V AC, 125 & 160 Amps Sizes 00 Time Current Characteristics for Size 00 Size 00 Details: Standards/Approvals: Rated Currents: IEC60269, DIN 43 620, VDE0636 125 & 160 Amps Part Number Amp Rating 125NHG00B-400 125 160NHG00B-400 160 I2t(Ampere 2 seconds) Minimum Pre-arcing I1 120kA @ 400Vac 60000 126000 25000 80000 Watts Loss 8.0 7.8 Net weight per fuse Rated Voltage 0.185 kg 400Vac Form No. NH Page 3 of 7 Data sheet 720099 Cooper Bussmann(R)(R) Bussmann NH DIN Dual Indication Fuse Links NH Class of Operation gL/gG, 400V AC, 35 to 250 Amps Sizes 01 & 1 Time Current Characteristics for Size 01 & 1 Size 01 & 1 Details: Standards/Approvals: Rated Currents: IEC60269, DIN 43 620, VDE0636 35, 40, 50, 63, 80, 100, 125, 160, 200, 224 & 250 amps Part Number Amp Rating 35NHG01B-400 40NHG01B-400 50NHG01B-400 63NHG01B-400 80NHG01B-400 100NHG01B-400 125NHG01B-400 160NHG01B-400 200NHG1B-400 224NHG1B-400 250NHG1B-400 35 40 50 63 80 100 125 160 200 224 250 I2t(Ampere 2 seconds) Minimum I1 120kA Pre-arcing @ 400Vac 2400 3300 4200 6600 9600 16000 24000 53000 89000 119000 171000 7600 10600 10400 16300 33600 56000 86400 111300 232000 322000 479000 Watts Loss 4.9 5.0 4.7 5.6 5.6 6.8 8.8 8.9 12.0 12.0 14.0 Net weight per fuse 0.269kg Rated Voltage 400Vac 0.387kg Form No. NH Page 4 of 7 Data sheet 720099 Cooper Bussmann(R)(R) Bussmann NH DIN Dual Indication Fuse Links NH Class of Operation gL/gG, 400V AC, 35 to 400 Amps Sizes 02 & 2 Time Current Characteristics for Size 02 & 2 Size 02 &2 Details: Standards/Approvals: Rated Currents: IEC60269, DIN 43 620, VDE0636 35, 40, 50, 63, 80, 100, 125, 160, 200, 224, 250, 315, 355 and 400 Amps Part Number Amp Rating 35NHG02B-400 40NHG02B-400 50NHG02B-400 63NHG02B-400 80NHG02B-400 100NHG02B-400 125NHG02B-400 160NHG02B-400 200NHG02B-400 224NHG02B-400 250NHG02B-400 315NHG2B-400 355NHG2B-400 400NHG2B-400 35 40 50 63 80 100 125 160 200 224 250 315 355 400 I2t(Ampere 2 seconds) Minimum Pre-arcing 2400 3300 4200 6600 10000 16000 24000 50000 89000 119000 171000 280000 350000 504000 I1 120kA @ 400Vac 7600 10600 10400 16300 34800 56000 86400 185000 232000 322000 479000 924000 1155000 1673100 Watts Loss 4.4 5.0 6.5 5.5 5.5 6.6 8.7 10.0 12.0 12.0 14.0 19.0 22.0 24.0 Net weight per fuse Rated Voltage 0.402kg 400Vac 0.630kg Form No. NH Page 5 of 7 Data sheet 720099 Cooper Bussmann(R)(R) Bussmann NH DIN Dual Indication Fuse Links NH Class of Operation gL/gG, 400V AC, 250 to 630 Amps Sizes 03 & 3 Time Current Characteristics for Size 03 & 3 Size 03 & 3 Details: Standards/Approvals: Rated Currents: IEC60269, DIN 43 620, VDE0636 250, 315, 355, 400, 500 and 630 Amps Part Number Amp Rating 250NHG03B-400 315NHG03B-400 355NHG03B-400 400NHG03B-400 500NHG3B-400 630NHG3B-400 250 315 355 400 500 630 I2t(Ampere 2 seconds) Minimum Pre-arcing 115000 280000 350000 504000 686000 1590000 I1 120kA @ 400Vac 379500 924000 1155000 1663000 2605000 6201000 Watts Loss 18.0 19.0 22.0 24.0 30.0 36.0 Net weight per fuse 0.634kg Rated Voltage 400Vac 1.043kg Form No. NH Page 6 of 7 Data sheet 720099 NH DIN Dual Indication Fuse Links Class of Operation gL/gG, 400V AC, 2 to 630 Amps Cooper Bussmann(R)(R) Bussmann NH Cut off Current Characterstics Size 000 to 3 Details: Standards/Approvals: Rated Currents: IEC60269, DIN 43 620, VDE0636 Part 1 2 to 630 amps Form No. NH Page 7 of 7 Data sheet 720099