Catalog 1308242 Issued 3-03 (PDF Revised 8-06) P&B T9A series DC Coil 30 Amp PC Board or Panel Mount Relay File E22575 File LR15734 Users should thoroughly review the technical data before selecting a product part number. It is recommended that user also seek out the pertinent approvals files of the agencies/laboratories and review them to ensure the product meets the requirements for a given application. Features Initial Dielectric Strength * Up to 30 amp switching in SPST and 20 amp in SPDT arrangements. * Wash-tight (washable)(6), plastic case available. * Meets UL 873 and UL 508 spacing - 1/8" through air, 1/4" over surface. * Load connections made via 1/4" Q. C. terminals and safety wells accept insulated female Q. C. terminals (mounting codes 2 & 5). * UL Class F insulation system standard. * Well suited for various industrial, commercial and residential applications. Between Open Contacts: 1,500V rms. Between Contacts and Coil: 2,500V rms. 6 kV surge using 1.2s/50s Impulse Wave or .5s - 100kHz Ring Wave Initial Insulation Resistance Contact Ratings @ 25C Arrangements: 1 Form A (SPST-NO), and 1 Form C (SPDT). Material: Silver-cadmium oxide. Mechanical Life: 10 million operations, typical. Minimum Contact Load: 1A @ 5VDC or 12VAC. Initial Contact Resistance: 75 milliohms, max., @ min. rated current (switched). Contact Ratings @ 25C (unless otherwise noted) with relay properly vented. Remove vent nib after soldering and cleaning. Typical Electrical Load & Life - 1 Watt Coil Contact Arrangement Contact Load Type of Load Operations 1 30A @ 240VAC 25A @ 240VAC UL General Purpose Resistive Heater 100,000 100,000 5 20A/10A @ 240VAC 20A/10A @ 240VAC 20A/10A @ 28VDC UL General Purpose UL Resistive Resistive 100,000 100,000 100,000 UL 508/873 & CSA Contact Ratings - 900mW Coil Voltage Load Type 240VAC General Purpose 240VAC Resistive 240VAC Resistive 240VAC LRA/FLA 120VAC LRA/FLA 120VAC LRA/FLA N.O. Contact N.C. Contact Operations 30A 18A - 30A/15A 50A/16A 30A/11A - - 15A - - - 100,000 100,000 @ 105C 6,000 100,000 100,000 200,000 Note: Consult factory for other 900mW version contact ratings. UL 508/873 & CSA Contact Ratings - 1 Watt Coil Voltage Load Type N.O. Contact N.C. Contact 277VAC 277VAC 240VAC 240VAC 240VAC 240VAC 240VAC 125VAC 120VAC 120VAC 120VAC 28VDC Tungsten * Ballast Motor Resistive * General Purpose LRA/FLA ** Pilot Duty * Motor LRA/FLA Tungsten * Pilot Duty Resistive 5.4A 10A 2 HP 25A 30A 80A/30A 470VA 1 HP 98A/22A 8.3A 470VA 20A - 3A 1/2 HP 20A 15A 30A/12A 275VA 1/4 HP - - - 10A * Rated 6,000 operations. ** Higher UL & CSA ratings available. For Form C application, derate current to 20A (N.O.), 10A (N.C.). For Form C application, derate current to 67%. Between Mutually Insulated Elements: 109 ohms, min., @ 500VDC, 25C and 50% R.H. Coil Data @ 25C Voltage: 5 to 110VDC. Nominal Coil Power: 1.0W, (approx.) and 900mW (approx.) versions. Maximum Coil Power: 2.8 Watt. Maximum Coil Temperature(5): Class F: 155C. Duty Cycle: Continuous. Coil Data - 1 Watt Nominal Voltage 5 6 9 12 15 18 22 24 48 110 DC Resistance 10% (Ohms) 25 36 81 144 225 324 484 576 2,304 12,100 Nominal Current (mA) 200 167 111 83 67 56 45 42 21 9 DC Resistance 10% (Ohms) 27 40 97 155 256 380 450 545 660 890 1,450 2,560 13,450 Nominal Current (mA) 185 150 93 77 59 47 44 40 36 31 25 19 8 Coil Data - 900mW Nominal Voltage 5 6 9 12 15 18 20 22 24 28 36 48 110 Operate Data @ 25C Must Operate Voltage: 75% of nominal voltage or less. Must Release Voltage: 10% of nominal voltage or more. Operate Time (Including Bounce): 15 ms, max. Release Time (Including Bounce): 15 ms, max. At or From Nominal Coil Voltage Note: Consult factory for other 900mW version contact ratings. Dimensions are shown for 506 reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover. Catalog 1308242 Issued 3-03 (PDF Revised 8-06) P&B Ambient Temperature vs. Coil Voltage - 1 Watt Coil Environmental Data Data below are average values and should be verified in application. Tests were conducted within a 2' (.6 m) cube (still air); at nominal coil power @ 25C; with normally open contact loaded; and with 4' (1.22 m) long, #10 AWG load wires. P.C. board relays were mounted to a 30A, single side P.C. board (6). Storage Temperature Range: -55C to 130C. Operating Temperature Range(1): -55C to +85C. Vibration, Operational: 0.065" (1.65mm) max. excursions from 10-55 Hz. with no contact opening >100s. Shock, Operational: 10g for 11 ms with no contact opening >100s. Shock, Mechanical: 100g. 140 Max. Alowable Ambient Temp. (C) 120 100 80 0A 10A 20A 60 40 20 Wash-Tight Relay, Vented (note 3); Load Connections Via Q.C. Terminals, PC Mount 0 60 80 30A 100 120 140 160 Applied Coil Voltage (% of Rated Voltage) 180 Max. Alowable Ambient Temp. (C) 140 120 Termination: Printed circuit and quick connect terminals (4). Enclosures (all have 94V-0 flammability rating): T9AP: Dust protected plastic case T9AS: Wash-tight plastic case (washable) (2 & 3). T9AV: Flux-proof plastic case. Weight: Q.C. version: 1.2 oz. (33g) approx. (mounting code 2 & 5). Wash-tight Model T9AS: 0.9 oz. (26g) approx. (mounting code 1). 100 0A 10A 20A 80 60 Dust Protected Relay, Flange Mount 40 60 80 30A 100 120 140 160 Applied Coil Voltage (% of Rated Voltage) 180 Notes 140 120 Max. Alowable Ambient Temp. (C) Mechanical Data 100 80 60 0A 10A 20A 40 20 Wash-Tight Relay, Vented (note 3) PC Terminals For Coil & Contacts 0 60 80 30A 100 120 140 160 Applied Coil Voltage (% of Rated Voltage) 180 (1) Operating ambient temperature must consider "Must Operate Voltage Change Over Temperature," Contact Temperature Rise, Coil Temperature Rise (If coil is not allowed to cool) and Maximum Coil Temperature. Specification ambient considers 20A load with coil cooled to ambient. (2) Wash-tight relay terminals should not be bent. (3) Remove knock-off nib after cleaning process for optimum life of wash-tight relays. (4) Maximum soldering temperature is 500F for 4 seconds. (5) Class F coils are UL systems approved for maximum coil temperature of 140C, by change of resistance method. (6) See application note 13C265 for proper relay mounting, termination, cleaning and PC board conductor width. Coil rise test performed with 30A PC board to maintain 20C maximum rise @ 30A. Ordering Information Typical Part Number B T9A S 5 D 2 2 -12 1. Basic Series: T9A = Low cost, printed circuit board/panel power relay. 2. Enclosure: P = Dust protected plastic case (mounting code 5). S = Wash-tight (washable) plastic case with knock off nib (mounting codes 1 & 2). V = Flux-proof plastic case (mounting code 1). 3. Contact Arrangement: 1 = 1 Form A (SPST-NO). 5 = 1 Form C (SPDT). 4. Coil Input: D = DC voltage (1 Watt) L = DC voltage (900mW) 5. Mounting & Termination: 1 = Printed circuit board mounting; PC terminals for coil & contacts (a). 2 = Printed circuit board mounting; PC terminals for coil & contacts, and .250" (6.35mm) quick connects for contacts (b). 5 = Flanged mounting; .187" (4.75mm) quick connects for coil and .250" (6.35mm) quick connects for contacts (c). 6. Contact Material: 2 = Silver-cadmium oxide. 7. Coil Voltage: 5 = 5VDC 6 = 6VDC 9 = 9VDC 12 = 12VDC 15 = 15VDC 18 = 18VDC a) Only available with enclosure code "S" & "V". 20 = 20VDC 22 = 22VDC b) Only available with enclosure code "S". 24 = 24VDC 28 = 28VDC 36 = 36VDC 48 = 48VDC 110 = 110VDC c) Only available with enclosure code "P". NOTE: All part numbers are RoHS compliant. Our authorized distributors are more likely to maintain the following items in stock for immediate delivery. T9AP1D52-9 T9AP1D52-12 T9AP5D52-12 T9AP5D52-24 T9AS1D12-12 T9AS1D12-18 T9AS1D12-24 T9AS1D12-48 T9AS1D22-12 T9AS1D22-24 Dimensions are shown for reference purposes only. T9AS5D12-12 T9AS5D12-24 T9AS5D22-12 T9AS5D22-24 T9AV1L22-24 Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: 507 Refer to inside back cover. Catalog 1308242 Issued 3-03 (PDF Revised 8-06) P&B Outline Dimensions T9AS - Mounting & Termination Code 2 .250 x .032 QUICK (6.35 x .81) CONNECT T9AP - Mounting & Termination Code 5 .187 x .020 (4.75 x .508) QUICK CONNECT .130 .020 (3.30 .51) COM 1.980 MAX. (50.29) .045 x .045 (1.14 x 1.14) NO NO 1.280 MAX. (32.51) 1.713 .010 (43.51 .25) 1.280 MAX. (32.51) NC .032 x .062 (.81 x 1.57) NC 1.100 MAX. (27.94) .250 x .032 (6.35 x .81) QUICK CONNECT O .03 (.80) 2 PLACES COM 1.080 MAX. (27.43) 1.100 MAX. (27.94) 1.080 MAX. (27.43) .071 (1.80) RAD. FOR #6 SCREW Note: Recommended mounting screw torque is 4.0-5.0 lbs.in when #6 screw is used. T9AS/V - Mounting & Termination Code 1 .805 MAX. (20.4) .130 + .016 - .010 3.30 + .41 -.25 ( ) .032 x .062 (.8 x 1.6) TERMINALS .10 MAX. (2.54) .50 (12.8) .69 (17.6) .212 MAX. (5.38) 1.280 MAX. (32.51) .016 (.43) 1.08 MAX. (27.43) O .03 (.80) TERMINALS .045 x .045 (1.14 x 1.14) TERMINAL Wiring Diagrams (Bottom Views) PC Board Layouts (Bottom Views) 1 Form A T9AP/S - Mounting & Termination Code 2 1 Form C .140 MAX. (3.56) .250 MAX. (6.35) .300 .100 (7.62) (2.54) .081 .005 DIA. (2.06 .13) .078 .003 DIA. (1.98 .08) .043 .003 DIA. (1.09 .08) .600 (15.24) .500 (12.7) .150 (3.81) .550 (13.97) .700 (17.78) T9AS/V - Mounting & Termination Code 1 .212 MAX. (5.38) .300 (7.62) .100 (2.54) .081 .005 DIA. (2.06 .13) .078 .003 DIA. (1.98 .08) .600 (15.24) .500 (12.7) .043 .003 DIA. (1.09 .08) .150 (3.81) .550 (13.97) .700 (17.78) Dimensions are shown for 508 reference purposes only. Dimensions are in inches over (millimeters) unless otherwise specified. Specifications and availability subject to change. www.tycoelectronics.com Technical support: Refer to inside back cover.