Bussmann(R) HRCII-C Current-Limiting Fuses CGL 600 Volt, 1 to 600 Amps Dimensional Data 0.22" 0.81" 0.22" (20.64mm) (5.56mm) (5.56mm) 0.06" 2.0" (50.8mm) (1.59mm) 0.34" 2.80" 0.94" (8.73mm) (23.81mm) (71.04mm) 3.31" (84.14mm) CGL 1-30 0.22" 0.81" 0.22" (20.64mm) (5.56mm) (5.56mm) 0.06" 2.0" (50.8mm) (1.59mm) 0.50" 2.80" 1.06" (12.7mm) (71.04mm) (26.92mm) 3.5" (88.9mm) CGL 40-50 Catalog Symbol: CGL Current-Limiting Ampere Rating: 1 to 600 Amperes Voltage Rating: 600 Volts AC (or less) 1 to 30 Amps, 250 Volts DC (or less) Interrupting Rating: 200,000A RMS Sym. 40,000A DC (1 to 30A) Agency Approval: CSA Certified, C22.2106, Class 1422, File 53787 General Information: TRON(R) HRC FORM II Class C Fuses * TRON(R) HRCII-C fuses are designed to withstand inrush currents on typical motor start-ups while offering high current limitation in the short-circuit region. * The TRON(R) HRCII-C fuses can be sized close to the motor nameplate rating. * Closer protection is offered for many motor sizes with the availability of these additional fuse ratings. * TRON(R) HRCII-C fuses have a high degree of current-limitation greatly reducing the magnetic forces and thermal stresses produced in today's high capacity systems. * TRON(R) HRCII-C fuses have an interrupting rating of 200,000 RMS symmetrical amperes at 600 volts. * TRON(R) HRCII-C fuses are dimensionally interchangeable with other Form II fuses on the market and can be used with the same confidence as other High Quality Buss Fuses. 1.34" 0.343" 0.343" (8.71mm) (8.71mm) 2.39" (60.72mm) 3.64" (34.04mm) 0.09" (2.29mm) 0.75" 1.375" (19.05mm) (34.93mm) (92.47mm) 4.31" (109.54mm) CGL 70-100 0.343" (8.71mm) 0.343 (8.71mm) 0.125" 3.00" (3.18mm) 0.75" (76.2mm) (19.05mm) 4.30" (109.22mm) 1.50" (38.1mm) 5.31" (134.87mm) CGL 125-200 0.19" (4.76mm) 1.0" 0.38" (25.4mm) (9.53mm) 1.0" (25.4mm) 3.0" 2.38" (76.2mm) (60.33mm) 5.25" (133.35mm) 8.19" (207.96mm) CGL 225-400 1.0" 0.41" (25.4mm) (10.32mm) 1.0" (25.4mm) .60" 3.0" (76.2mm) 5.25" (133.35mm) 8.19" (15.24mm) 0.375" (9.53mm) 3.00" (76.2mm) (207.96mm) CGL 450-600 5-02-01 SB01155 Form No. CGL Page 1 of 3 BIF Doc #4125 Bussmann(R) HRCII-C Current-Limiting Fuses CGL 600 Volt, 1 to 600 Amps 500 600 150 80 300 400 350 450 200 250 100 125 60 40 1,000 25 30 AMPERE RATING 1,000 50 CGL - Minimum Melt 6 8 10 15 20 3 4 2 1 CGL - Minimum Melt AMPERE RATING 100 100 10 TIME IN SECONDS TIME IN SECONDS 10 1 1 .1 1,000 10 1 .01 100 .1 20,000 10,000 1000 40 .01 100 CURRENT IN AMPERES CURRENT IN AMPERES 5-02-01 SB01155 Form No. CGL Page 2 of 3 BIF Doc #4125 Bussmann(R) HRCII-C Current-Limiting Fuses CGL 600 Volt, 1 to 600 Amps B AMPERE RATING 400,000 100,000 600 400 200 100 60 10,000 30 200,000 10,000 1,000 100,000 A 1,000 INSTANTANEOUS PEAK LET-THROUGH CURRENT IN AMPS CGL LIMITRON PROSPECTIVE SHORT-CIRCUIT CURRENT SYMMETRICAL RMS AMPS The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 5-02-01 SB01155 Form No. CGL Page 3 of 3 BIF Doc #4125