2 3 2 2 3 3 1 1 4 1 SO 4 Anti-Parallel Parallel APT2X60D30J APT2X61D30J 27 2 T- 4 APT2X61D30J APT2X60D30J 300V 300V 60A 60A DUAL DIE ISOTOP(R) PACKAGE ULTRAFAST SOFT RECOVERY RECTIFIER DIODE PRODUCT APPLICATIONS PRODUCT FEATURES PRODUCT BENEFITS * Anti-Parallel Diode * Ultrafast Recovery Times * Low Losses * Soft Recovery Characteristics * Low Noise Switching * Popular SOT-227 Package * Cooler Operation * Low Forward Voltage * Higher Reliability Systems * High Blocking Voltage * Increased System Power * * * * * -Switchmode Power Supply -Inverters Free Wheeling Diode -Motor Controllers -Converters Snubber Diode Uninterruptible Power Supply (UPS) Induction Heating High Speed Rectifiers * Low Leakage Current MAXIMUM RATINGS Symbol VR Density All Ratings: TC = 25C unless otherwise specified. Characteristic / Test Conditions APT2X61_60D30J UNIT 300 Volts Maximum D.C. Reverse Voltage VRRM Maximum Peak Repetitive Reverse Voltage VRWM Maximum Working Peak Reverse Voltage IF(AV) Maximum Average Forward Current (TC = 91C, Duty Cycle = 0.5) 60 RMS Forward Current (Square wave, 50% duty) 86 IF(RMS) IFSM TJ,TSTG Amps 600 Non-Repetitive Forward Surge Current (TJ = 45C, 8.3ms) -55 to 150 Operating and StorageTemperature Range C STATIC ELECTRICAL CHARACTERISTICS Forward Voltage IRM Maximum Reverse Leakage Current CT Junction Capacitance, VR = 200V TYP MAX IF = 60A 1.2 1.4 IF = 120A 1.5 IF = 60A, TJ = 125C 1.0 Volts VR = VR Rated 250 VR = VR Rated, TJ = 125C 500 APT Website - http://www.advancedpower.com UNIT A 150 pF 9-2003 VF MIN 053-4056 Rev A Symbol DYNAMIC CHARACTERISTICS Symbol APT2X61_60D30J Characteristic Test Conditions MIN TYP MAX UNIT trr Reverse Recovery Time I = 1A, di /dt = -100A/s, V = 30V, T = 25C F F R J - 29 trr Reverse Recovery Time - 38 Qrr Reverse Recovery Charge - 75 - 4 - 80 ns - 370 nC - 8 - 55 ns - 740 nC - 23 Amps MIN TYP IRRM IF = 60A, diF/dt = -200A/s VR = 200V, TC = 25C Maximum Reverse Recovery Current trr Reverse Recovery Time Qrr IF = 60A, diF/dt = -200A/s Reverse Recovery Charge IRRM VR = 200V, TC = 125C Maximum Reverse Recovery Current trr Reverse Recovery Time Qrr IF = 60A, diF/dt = -800A/s Reverse Recovery Charge IRRM VR = 200V, TC = 125C Maximum Reverse Recovery Current ns nC - - Amps Amps THERMAL AND MECHANICAL CHARACTERISTICS Symbol Characteristic / Test Conditions MAX RJC Junction-to-Case Thermal Resistance .60 RJA Junction-to-Ambient Thermal Resistance 20 WT Torque C/W 1.03 oz 29.2 g Package Weight 10 lb*in 1.1 N*m Maximum Terminal & Mounting Torque APT Reserves the right to change, without notice, the specifications and information contained herein. 0.60 0.9 0.50 0.7 0.40 0.5 0.30 Note: PDM Z JC, THERMAL IMPEDANCE (C/W) 0.70 0.3 0.20 Duty Factor D = t1/t2 0.1 0.05 10-5 Peak TJ = PDM x ZJC + TC SINGLE PULSE 10-4 10-3 10-2 10-1 1.0 RECTANGULAR PULSE DURATION (seconds) FIGURE 1a. MAXIMUM EFFECTIVE TRANSIENT THERMAL IMPEDANCE, JUNCTION-TO-CASE vs. PULSE DURATION RC MODEL Junction temp (C) 9-2003 t1 t2 0.10 0 053-4056 Rev A UNIT Power (watts) 0.159 C/W 0.00560 J/C 0.255 C/W 0.0849 J/C 0.186 C/W 0.489 J/C Case temperature (C) FIGURE 1b, TRANSIENT THERMAL IMPEDANCE MODEL APT2X61_60D30J TYPICAL PERFORMANCE CURVES 180 IF, FORWARD CURRENT (A) 160 140 120 100 80 TJ = 25C 60 TJ = 125C 40 TJ = 150C 0.05 1 1.5 2 VF, ANODE-TO-CATHODE VOLTAGE (V) Figure 2. Forward Current vs. Forward Voltage 60A 30A 60 40 20 0 200 400 600 800 1000 -diF /dt, CURRENT RATE OF CHANGE(A/s) Figure 3. Reverse Recovery Time vs. Current Rate of Change 25 TJ = 125C VR = 200V 800 120A 60A 600 30A 400 200 0 0 200 400 600 800 1000 -diF /dt, CURRENT RATE OF CHANGE (A/s) Figure 4. Reverse Recovery Charge vs. Current Rate of Change IRRM, REVERSE RECOVERY CURRENT (A) Qrr, REVERSE RECOVERY CHARGE (nC) 120A 80 0 0 1000 TJ = 125C VR = 200V 20 15 60A 30A 10 5 0 200 400 600 800 1000 -diF /dt, CURRENT RATE OF CHANGE (A/s) Figure 5. Reverse Recovery Current vs. Current Rate of Change 100 Duty cycle = 0.5 TJ = 150C Qrr 1.2 120A 0 1.4 80 trr 1.0 trr 0.8 IF(AV) (A) Kf, DYNAMIC PARAMETERS (Normalized to 800A/s) TJ = 125C VR = 200V TJ = -55C 20 0 trr, REVERSE RECOVERY TIME (ns) 100 IRRM 0.6 60 40 0.4 Qrr 0.2 0.0 20 0 0 25 50 75 100 125 150 TJ, JUNCTION TEMPERATURE (C) Figure 6. Dynamic Parameters vs. Junction Temperature 25 50 75 100 125 150 Case Temperature (C) Figure 7. Maximum Average Forward Current vs. CaseTemperature 1000 800 600 9-2003 400 200 0 6 1 10 100 200 VR, REVERSE VOLTAGE (V) Figure 8. Junction Capacitance vs. Reverse Voltage 053-4056 Rev A CJ, JUNCTION CAPACITANCE (pF) 1200 APT2X61_60D30J Vr diF /dt Adjust +18V APT30M36LLL 0V D.U.T. 30H trr/Qrr Waveform PEARSON 2878 CURRENT TRANSFORMER Figure 9. Diode Test Circuit 1 IF - Forward Conduction Current 2 diF /dt - Rate of Diode Current Change Through Zero Crossing. 3 IRRM - Maximum Reverse Recovery Current. 4 trr - Reverse Recovery Time, measured from zero crossing where diode current goes from positive to negative, to the point at which the straight line through IRRM and 0.25 IRRM passes through zero. 5 1 4 Zero 5 0.25 IRRM 3 2 Qrr - Area Under the Curve Defined by IRRM and trr. Figure 10, Diode Reverse Recovery Waveform and Definitions SOT-227 Package Outline 11.8 (.463) 12.2 (.480) 31.5 (1.240) 31.7 (1.248) 7.8 (.307) 8.2 (.322) r = 4.0 (.157) (2 places) 8.9 (.350) 9.6 (.378) Hex Nut M4 H100 (4 places) W=4.1 (.161) W=4.3 (.169) H=4.8 (.187) H=4.9 (.193) (4 places) 25.2 (0.992) 0.75 (.030) 12.6 (.496) 25.4 (1.000) 0.85 (.033) 12.8 (.504) 4.0 (.157) 4.2 (.165) (2 places) 9-2003 053-4056 Rev A 3.3 (.129) 3.6 (.143) 14.9 (.587) 15.1 (.594) 38.0 (1.496) 38.2 (1.504) 30.1 (1.185) 30.3 (1.193) Dimensions in Millimeters and (Inches) 1.95 (.077) 2.14 (.084) Anti-parallel Parallel APT2X60D30J APT2X61D30J Anode 2 Cathode 2 Cathode 1 Cathode 1 Anode 1 Anode 1 Anode 2 Cathode 2 ISOTOP(R) is a Registered Trademark of SGS Thomson. APT's products are covered by one or more of U.S.patents 4,895,810 5,045,903 5,089,434 5,182,234 5,019,522 5,262,336 6,503,786 5,256,583 4,748,103 5,283,202 5,231,474 5,434,095 5,528,058 and foreign patents. US and Foreign patents pending. All Rights Reserved.