GL100MN0MPx GL100MN0MPx Surface Mount Type, Infrared Emitting Diode Features Agency Approvals/Compliance 1. 2. 3. 4. 5. 6. 1. Compliant with RoHS directive (2002/95/EC) 2. Content information about the six substances specified in "Management Methods for Control of Pollution Caused by Electronic Information Products Regulation" (popular name: China RoHS) (Chinese: ); refer to page 7. Compact and thin SMD package Top view and side view mountable Plastic mold with resin lens Peak emission wavelength: 940 nm TYP. Narrow directivity angle (: 10 TYP.) Lead free and RoHS directive compliant Model Line-up Model No. Applications Packaging Mount Direction GL100MN0MP 2000 pcs/reel Side view GL100MN0MP1 1500 pcs/reel Top view 1. 2. 3. 4. 5. 6. 7. Office automation equipment Audio visual equipment Home appliances Telecommunication equipment Measuring equipment Tooling machines Computers Notice The content of data sheet is subject to change without prior notice. In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device. 1 Sheet No.: D1-A00601EN Date: May 30, 2007 (c)SHARP Corporation GL100MN0MPx External Dimensions 3.0 (0.4) 1.5 0.95 0.65 0.75 (0.2) (0.35) 2.2 1.5 0.4 1.0 2.2 R0.8 (0.57) (0.57) Pin Arrangement (0.65) 1 1 2 (1.0) (1.0) No. 2 Viewed from PCB (Side view Mounting) Viewed from PCB (Top view Mounting) 3.0 3.0 1.5 NOTES: 1. Unit: mm 2. Unspecified tolerance : 0.2 mm 3. ( ) : Reference dimensions 4. Au-plated area 5. Do not allow circuit runs in area 1.1 1 Anode 2 Cathode 1.1 1.7 1.4 0.85 1.5 Name 1.1 1.1 (Lens center) Sheet No.: D1-A00601EN 2 GL100MN0MPx Absolute Maximum Ratings Parameter (Ta = 25C) Symbol Rating Unit IF 50 mA Peak pulsed forward current *1 IFM 0.5 A Reverse voltage VR 6 V Power dissipation P 75 mW Operating temperature Topr -30 to +85 C Storage temperature Tstg -40 to+ 95 C Soldering temperature *2 Tsol 240 C Forward current width: 100 s, Duty ratio: 0.01 *12 Pulse * Within 10 s (MAX.) see Fig. 10. Electro-optical Charactertistics Parameter (Ta = 25C) Symbol Conditions MIN. TYP. MAX. Unit VF IF = 20 mA - 1.2 1.4 V VFM IFM = 0.5 A - 3.0 4.0 V Reverse current IR VR = 3 V - - 10 A Radiant intensity e IF = 20 mA 1.0 - 3.0 mW Peak emission wavelength p IF = 5 mA - 940 - nm Half intensity wavelength IF = 5 mA - 45 - nm Terminal capacitance Ct VR = 0, f = 1 MHz - 50 - pF Response frequency fC - - 300 - kHz Half-intensity angle - - 10 - degrees Forward voltage Peak forward voltage Fig. 1 Forward Current vs. Ambient Temperature Fig. 2 Peak Forward Current vs. Duty Ratio Peak forward current IFM (mA) 10000 60 Forward current IF (mA) 50 40 30 20 Ta = 25C 1000 100 10 10-4 10 Pulse width 100 s 10-3 10-2 10-1 100 Duty ratio 0 -50 -30 -25 85 0 25 50 75 100 Ambient temperature Ta (C) Sheet No.: D1-A00601EN 3 GL100MN0MPx Fig. 3 Spectral Distribution Fig. 5 Forward Current vs. Forward Voltage 100 1000 Ta = 85C 80 Forward current IF (mA) Relative radiant intensity (%) IF = 5 mA Ta = 25C 60 40 20 25C 50C 100 0C -30C 10 1 0 860 880 900 920 940 960 980 1000 1020 1040 0.1 Wavelength (nm) 0 1 1.5 2 2.5 3 Forward voltage VF (V) Fig. 4 Peak Emission Wavelength vs. Ambient Temperature Fig. 6 Relative Radiant Flux vs. Ambient Temperature 980 IF = constant 10 970 IF = constant 960 Relative radiant flux (%) Peak emission wavelength p (nm) 0.5 950 940 930 920 -50 -30 -25 0 25 50 1 75 85 100 0.1 -50 Ambient temperature Ta (C) -30 -25 0 25 50 75 85 100 Ambient temperature Ta (C) Sheet No.: D1-A00601EN 4 GL100MN0MPx Fig. 7 Radiant Flux vs. Forward Current 100 Fig. 9 Radiation Diagram -20 Ta = 25C -10 0 +10 +20 -30 Radiant flux e (mW) 10 1 -40 Pulse (Pulse width 100 ms) -50 0.1 -60 Relative radiant intensity (%) 100 +30 80 60 40 1 10 100 1000 -70 +70 -80 +80 -90 Forward current IF (mA) +50 +60 20 0.01 +40 0 Angular displacement +90 Fig. 8 Relative Output vs. Distance to Detector (Detector: PT100MF0MP) 100 IF = constant Ta = 25C Relative output (%) 10 1 0.1 0.01 0.1 1 10 100 1000 Distance to detector (mm) Sheet No.: D1-A00601EN 5 GL100MN0MPx Design Considerations Design Guidelines 1. Allow for natural degradation of the LED as a result of long continuous operation. This part will have 50% degradation in output after 5 years of continuous use. 2. This product is not designed to be electromagnetic- and ionized-particle-radiation resistant. Manufacturing Guidelines Soldering Instructions 1. Sharp recommends soldering no more than once when using solder reflow methods. 2. When using solder reflow methods, follow the Reflow Soldering Temperature Profile shown in Fig. 10. Sharp recommends checking the process to make sure these parameters are not exceeded; exceeding these parameters can cause substrate bending or other mechanical stresses leading to debonding of the internal gold wires, or other similar failure modes. 3. If using an infrared lamp to preheat the parts, such heat sources may cause localized high temperatures in the part's resin. Be sure to keep the temperature profile within the guidelines shown in Fig. 10. 4. If hand soldering, use temperatures 260 for 3 seconds. Do not dip-solder or VPS-solder this part. 5. Do not subject the package to excessive mechanical force during soldering as it may cause deformation or defects in plated connections. Internal connections may be severed due to mechanical force placed on the package due to the PCB flexing during the soldering process. Fig. 10 Reflow Soldering Temperature Profile 240C MAX. 200C 1 ~ 4C/s 165C MAX. 1 ~ 4C/s 1 ~ 4C/s 25C 10 s MAX. 60 s MAX. 120 s MAX. 90 s MAX. Cleaning Instructions 1. Confirm this device's resistance to process chemicals before use, as certain process chemicals may affect the optical characteristics. 2. Solvent cleaning: Solvent temperature should be 45C or below. Immersion time should be 3 minutes or less. 3. Ultrasonic cleaning: The effect upon devices varies due to cleaning bath size, ultrasonic power output, cleaning time, PCB size and device mounting circumstances. Sharp recommends testing using actual production conditions to confirm the harmlessness of the ultrasonic cleaning methods. 4. Recommended solvent materials: Ethyl alcohol, Methyl alcohol, and Isopropyl alcohol. Sheet No.: D1-A00601EN 6 GL100MN0MPx Storage and Handling 1. Store these parts between 5C and 30C, at a relative humidity of less than 70%. 2. After breaking the package seal, maintain the environment within 5C to 25C, at a relative humidity of less than 60%, and mount the parts within two days. If unable to do so, bake before mounting. 3. When storing the parts after breaking the seal, Sharp recommends storage of no longer than two weeks in a dry box or by resealing the parts in a moisture-proof bag with a desiccant. If unable to do so, bake before mounting. 4. When baking the parts before mounting, Sharp recommends baking the parts only once and only if in a metal tray or mounted on a PCB. Recommended conditions are for 16 to 24 hours, at a temperature of 125C. Presence of ODCs (RoHS Compliance) This product shall not contain the following materials, and they are not used in the production process for this product: * Regulated substances: CFCs, Halon, Carbon tetrachloride, 1,1,1-Trichloroethane (Methylchloroform). Specific brominated flame retardants such as the PBBOs and PBBs are not used in this product at all. This product shall not contain the following materials banned in the RoHS Directive (2002/95/EC). * Lead, Mercury, Cadmium, Hexavalent chromium, Polybrominated biphenyls (PBB), Polybrominated diphenyl ethers (PBDE). * Content information about the six substances specified in "Management Methods for Control of Pollution Caused by Electronic Information Products Regulation" (Chinese: ) Toxic and Hazdardous Substances Category Infrared Emitting Diode Lead (Pb) mercury (Hg) Cadmium (Cd) Hexavalent chromiun (Cr6+) Polybrominated biphenyls (PBB) Polybrominated diphenyl ethers (PBDE) NOTE: indicates that the content of the toxic and hazardous substance in all the homogeneous materials of the part is below the concentration limit requirement as described in SJ/T 11363-2006 standard. Taping Specifications 1. 2. 3. 4. 5. 6. Tape structure and dimensions conforms to those shown in Fig. 11 to Fig. 16. Product insertion will have the cathode to the hole side of the tape. Cover tape peel-separation force: F = 0.2 to 1.0 N (where 160 to 180) Quantity per reel = 2000 pcs. (GL100MN0MP) or 1500 pcs. (GL100MN0MP1) Product mass: 0.01 g (approx.) Packaging: a. Reels are sealed inside an aluminum bag, along with a humidity indicator card. b. Bags are labeled and securely packed. Sheet No.: D1-A00601EN 7 GL100MN0MPx Packing Specifications GL100MN0MP (Side view mount, 2000 pcs/reel) Fig. 11 Tape Shape and Dimension 1.75 0.1 4.0 0.1 0.3 0.05 5 8.0 0.3 3.3 0.1 5.5 0.1 1.7 0.1 3.5 0.05 1.75 0.1 2.0 0.05 1.5 +0.1 -0 4.0 0.1 1.6 0.1 2.5 0.1 Fig. 12 Reel Shape and Dimension +0.3 9.0 -0 2.0 0.5 60.0 -0 +1 13.0 0.2 180.0 11.4 1 NOTE: Unit: mm Sheet No.: D1-A00601EN 8 GL100MN0MPx Fig. 13 Product Insertion Direction Pull-out direction GL100MN0MP1 (Top view mount, 1500 pcs/reel) Fig. 14 Tape Shape and Dimension 2.45 0.1 4.0 0.1 0.3 0.05 8.0 0.3 5 5.5 0.1 3.3 0.1 3.5 0.05 1.75 0.1 2.0 0.05 1.5 +0.1 -0 4.0 0.1 1.8 0.1 Sheet No.: D1-A00601EN 9 GL100MN0MPx Fig. 15 Reel Shape and Dimension +0.3 9.0 -0 2.0 0.5 60.0 -0 +1 13.0 0.2 180.0 11.4 1 NOTE: Unit: mm Fig. 16 Product Insertion Direction Pull-out direction Sheet No.: D1-A00601EN 10 GL100MN0MPx Important Notices --- Transportation control and safety equipment (i.e., aircraft, trains, automobiles, etc.) --- Traffic signals --- Gas leakage sensor breakers --- Alarm equipment --- Various safety devices, etc. * The circuit application examples in this publication are provided to explain representative applications of SHARP devices and are not intended to guarantee any circuit design or license any intellectual property rights. SHARP takes no responsibility for any problems related to any intellectual property right of a third party resulting from the use of SHARP's devices. (iii) SHARP devices shall not be used for or in connection with equipment that requires an extremely high level of reliability and safety such as: --- Space applications --- Telecommunication equipment (trunk lines) --- Nuclear power control equipment --- Medical and other life support equipment (e.g. scuba) * Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device. SHARP reserves the right to make changes in the specifications, characteristics, data materials, structure, and other contents described herein at any time without notice in order to improve design or reliability. Manufacturing locations are also subject to change without notice. * If the SHARP devices listed in this publication fall within the scope of strategic products described in the Foreign Exchange and Foreign Trade Law of Japan, it is necessary to obtain approval to export such SHARP devices. * Observe the following points when using any devices in this publication. SHARP takes no responsibility for damage caused by improper use of the devices which does not meet the conditions and absolute maximum ratings to be used specified in the relevant specification sheet nor meet the following conditions: (i) The devices in this publication are designed for use in general electronic equipment designs such as: --- Personal computers --- Office automation equipment --- Telecommunication equipment (terminal) --- Test and measurement equipment --- Industrial control --- Audio visual equipment --- Consumer electronics * This publication is the proprietary product of SHARP and is copyrighted, with all rights reserved. Under the copyright laws, no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, in whole or in part, without the express written permission of SHARP. Express written permission is also required before any use of this publication may be made by a third party. * Contact and consult with a SHARP representative if there are any questions about the contents of this publication. (ii) Measures such as fail-safe function and redundant design should be taken to ensure reliability and safety when SHARP devices are used for or in connection with equipment that requires higher reliabilty such as: Sheet No.: D1-A00601EN 11