GA152 Page 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2009 TELEDYNE RELAYS
GA152\102009\Q4
TELEDYNE RELAYS PART NUMBERING SYSTEM
FOR GA152 ATTENUATOR RELAYS
GA152 – 20* – XX
PARAMETER MINIMUM TYPICAL MAXIMUM UNITS
Operating Frequency (Note 2) 0.0 5.0 GHz
Power (Notes 5 and 6) 1.0 Watt
Impedance 50 Ohms
SERIES GA152
GENERAL PERFORMANCE (–55°C to + 85°C, unless otherwise speci ed)
ELECTRICAL SPECIFICATION (–55°C to +85°C, unless otherwise speci ed)
PART NUMBER (Note 7) GA152-dB-5 GA152-dB-12 GA152-dB-15 GA152-dB-26
Coil Voltage Vdc (Note 6) Nom. 5121526.5
Max. 5.8 16.0 20.0 32.0
Coil Resistance Ohms ±20% @25°C 50 390 610 1560
Pick-up Voltage Vdc Max. @25°C 3.8 9.0 11.3 18.0
Switching Time ms (Note 8) Max. 4.0
Typ. 2.0
Insulation Resistance 1,000 MΩ typical (all mutually isolated points)
Dielectric Strength 300 VRMS / 60 Hz typical (at sea level)
OUTLINE DIMENSIONS
GENERAL NOTES
1. Contacts will exhibit no contact chatter in excess of
10 μs or transfer in excess of 1 μs.
2. Relays may be operated at higher frequencies with
reduced RF performance.
3. For optimal RF performance, solder case to RF ground
plane.
4. Attenuation values shown are with reference to the
through path (low loss state).
5. Power handling for case temperatures of –55°C to
+55°C is 1 Watt. Derate power handling 25 mW/°C
above +55°C. Case measurement point is adjacent to
the relay tab.
6. Do not operate coil at maximum coil voltage
continuously.
7. Insert attenuation value, see part numbering system.
8. Switching time includes bounce.
9. The slash and characters appearing after the slash are
not marked on the relay.
10. Unless otherwise speci ed, relays will be supplied with
either gold-plated or solder-coated leads.
Series
Designator
Attenuation
Value (dB)
Nominal
Coil Voltage
*Contact factory for additional
attenuation values
.475 MAX
[ 12.06 ]
.335 MAX
[ 8.51 ]