Technical data
General specifications
Sensing range 30 ... 300 mm
Adjustment range 50 ... 300 mm
Unusable area 0 ... 30 mm
Standard target plate 100 mm x 100 mm
Transducer frequency approx. 390 kHz
Response delay approx. 30 ms
Indicators/operating means
LED yellow solid yellow: object in the evaluation range
yellow, flashing: program function, object detected
LED red solid red: Error
red, flashing: program function, object not detected
Electrical specifications
Operating voltage UB15 ... 30 V DC , ripple 10 %SS
No-load supply current I0 20 mA
Input
Input type 1 program input
lower evaluation limit A1: -UB ... +1 V, upper evaluation limit
A2: +4 V ... +UB
input impedance: > 4.7 k, pulse duration: 1 s
Output
Output type 1 analog output 0 ... 10 V
Default setting evaluation limit A1: 50 mm evaluation limit A2: 300 mm
Resolution 0.4 mm at max. sensing range
Deviation of the characteristic curve ± 1 % of full-scale value
Repeat accuracy ± 0.5 % of full-scale value
Load impedance > 1 kOhm
Temperature influence ± 1.5 % of full-scale value
Ambient conditions
Ambient temperature -25 ... 70 °C (-13 ... 158 °F)
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Mechanical specifications
Connection type Connector M12 x 1 , 4-pin
Protection degree IP67
Material
Housing brass, nickel-plated
Transducer epoxy resin/hollow glass sphere mixture; foam
polyurethane, cover PBT
Mass 25 g
Compliance with standards and
directives
Standard conformity
Standards EN 60947-5-2:2007
IEC 60947-5-2:2007
EN 60947-5-7:2003
IEC 60947-5-7:2003
Approvals and certificates
UL approval cULus Listed, General Purpose
CSA approval cCSAus Listed, General Purpose
Model Number
UB300-18GM40-U-V1
Single head system
Features
Short design, 40 mm
Function indicators visible from all
directions
Analog output 0 ... 10 V
Measuring window adjustable
Program input
Temperature compensation
Diagrams
Characteristic response curve
Distance X [mm]
Distance Y [mm]
Curve 1: flat surface 100 mm x 100 mm
Curve 2: round bar, Ø 25 mm
0 50 100 150 200 250 300 350 400 450 500
100
50
0
-50
-100
1
2
X
Y
Ultrasonic sensor UB300-18GM40-U-V1
2
Release date: 2013-06-24 12:40 Date of issue: 2013-07-31 127351_eng.xml
Germany: +49 621 776 4411Pepperl+Fuchs Group
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
USA: +1 330 486 0001 Singapore: +65 6779 9091
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com
fa-info@de.pepperl-fuchs.com
Adjusting the evaluation limits
Dimensions
Electrical Connection
Pinout
Accessories
UB-PROG2
Programming unit
OMH-04
Mounting aid for round steel ø 12 mm or sheet 1.5 mm ... 3 mm
BF 18
Mounting flange, 18 mm
BF 18-F
Mounting flange with dead stop, 18 mm
BF 5-30
Universal mounting bracket for cylindrical sensors with a diameter of 5 ... 30 mm
V1-G-2M-PVC
Female cordset, M12, 4-pin, PVC cable
V1-W-2M-PUR
Female cordset, M12, 4-pin, PUR cable
24.5
39.2
50.2
10
M12 x 1
M18 x 1
4
24
LED
3 (BU)
1 (BN)
2 (WH)
4 (BK)
U
+ U
B
Teach input
Analog output
- U
B
Core colors in accordance with EN 60947-5-2.
Standard symbol/Connections:
(version U)
Connector V1
2
31
4
Additional Information
Programmed analogue output function
Rising ramp
A1 < A2:
Falling ramp
A2 < A1:
object range
A1 A2
A2 A1
Ultrasonic sensor UB300-18GM40-U-V1
3
Release date: 2013-06-24 12:40 Date of issue: 2013-07-31 127351_eng.xml
Germany: +49 621 776 4411Pepperl+Fuchs Group
Refer to “General Notes Relating to Pepperl+Fuchs Product Information”.
USA: +1 330 486 0001 Singapore: +65 6779 9091
www.pepperl-fuchs.com fa-info@us.pepperl-fuchs.com fa-info@sg.pepperl-fuchs.com
fa-info@de.pepperl-fuchs.com
The ultrasonic sensor features an analogue output with two teachable evaluation limits. These are set by applying the supply
voltage -UB or +UB to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1 s. LEDs
indicate whether the sensor has recognised the target during the TEACH-IN procedure. The lower evaluation limit A1 is taught
with -UB, A2 with +UB.
Two different output functions can be set:
1. Analogue value increases with rising distance to object (rising ramp)
2. Analogue value falls with rising distance to object (falling ramp)
TEACH-IN rising ramp (A2 > A1)
- Position object at lower evaluation limit
- TEACH-IN lower limit A1 with - UB
- Position object at upper evaluation limit
- TEACH-IN upper limit A2 with + UB
TEACH-IN falling ramp (A1 > A2):
- Position object at lower evaluation limit
- TEACH-IN lower limit A2 with + UB
- Position object at upper evaluation limit
- TEACH-IN upper limit A1 with - UB
Default setting
A1: unusable area
A2: nominal sensing range
Mode of operation: rising ramp
LED Displays
Installation conditions
If the sensor is installed at places, where the environment temperature can fall below 0 °C, for the sensors fixation, one of the
mounting flanges BF18, BF18-F or BF 5-30 must be used.
In case of direct mounting of the sensor in a through hole using the steel nuts, it has to be fixed at the middle of the housing
thread. If a fixation at the front end of the threaded housing is required, plastic nuts with centering ring (accessories) must be
used.
Displays in dependence on operating mode Red LED Yellow LED
TEACH-IN evaluation limit
Object detected
No object detected
Object uncertain (TEACH-IN invalid)
off
flashes
on
flashes
off
off
Normal mode (evaluation range) off on
Fault on previous state