Low Signal Relay G5V-2 Miniature Relay for Signal Circuits * Suitable for handling low signals in computer peripherals, telecommunications and security equipment. * Capable of switching loads 10A to 2 A. * Conforms to FCC part 68 1,500 V surge withstand. * Reliable Ag + Au-clad, bifurcated crossbar contacts. * Fully-sealed construction. * RoHS Compliant. RC FCC Ordering Information To Order: Select the part number and add the desired coil voltage rating (e.g., G5V-2-DC12). Type Contact form Standard DPDT Construction Model Fully-sealed G5V-2 High-sensitivity G5V-2-H1 Model Number Legend G5V - 1 DC 2 3 2. Coil type Blank: Standard H1: High-sensitivity 1. Contact Form 2: DPDT 3. Rated Coil Voltage 3, 5, 6, 9, 12, 24, 48 VDC Specifications Contact Data Item Standard High-sensitivity Load Resistive load (p.f. = 1) Rated load 0.50 A at 125 VAC 2 A at 30 VDC Contact material Ag (Au clad) Carry current 2A Max. operating voltage 125 VAC 125 VDC Max. operating current 2A 1A Max. switching capacity 62.5 VA 60W 62.5 VA 24W Min. permissible load (See note) 0.5 A at 125 VAC 1 A at 24 VDC 10 A, 10 mVDC Note: P level: 60 = 0.1 x 10 /operation This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 . This value may vary depending on the switching frequency and operating environment. Always double-check relay suitability under actual operating conditions. -6 Low Signal Relay G5V-2 63 Coil Data Standard Type Rated voltage Rated current Coil (VDC) (mA) resistance () Coil inductance (Ref. value) (H) Pick-up voltage Armature OFF Armature ON 3 166.70 18 0.04 0.05 5 100 50 0.09 0.11 6 83.30 72 0.16 0.19 9 55.60 162 0.31 0.49 12 41.70 288 0.47 0.74 24 20.80 1,152 1.98 2.63 48 12 4,000 7.23 10.00 Dropout voltage Maximum voltage % of rated voltage 75% max. 5% min. 120% max. at 23C Power consumption (mW) Approx. 500 Approx. 580 High-sensitivity Type Rated voltage Rated current Coil (VDC) (mA) resistance () Coil inductance (Ref. value) (H) Pick-up voltage Armature OFF Armature ON 3 50 60 0.18 0.57 5 30 166.7 0.46 0.71 6 25 240 0.70 0.97 9 16.70 540 1.67 2.33 12 12.50 960 2.90 3.99 24 8.33 2,880 6.72 9.27 48 6.25 7,680 20.10 26.70 Dropout voltage Maximum voltage % of rated voltage 75% max. 5% min. 180% max. at 23C Power consumption (mW) Approx. 150 Approx. 200 150% max. at 23C Approx. 300 Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2. The operating characteristics are measured at a coil temperature of 23C. 3. The maximum voltage is the highest voltage that can be imposed on the relay coil. Characteristics Contact resistance (See note 1) 50 m max. (G5V-2); 100 m max. (G5V-2-H1) Operate time (See note 2) 7 ms max. (mean value: approx. 3.5 ms) Release time (See note 2) Operating frequency (max.) 3 ms max. (mean value: approx. 0.8 ms) Mechanical 36,000 operations/hour Electrical 1,800 operations/hour (under rated load) Insulation resistance (See note 3) 1,000 M min (at 500 VDC) Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between coil and contacts 1,000 VAC, 50/60 Hz for 1 minute between contacts of different poles 750 VAC, 50/60 Hz for 1 minute between contacts of same poles (500 VAC, 50/60 Hz for 1 minute between contacts of same poles for high-sensitive type) 1,500 V (10 X 160 s) between coil and contacts (conforms to part 68 of FCC rules) Surge withstand voltage Vibration Mechanical durability 10 to 55 Hz, 1.50 mm double amplitude Malfunction durability Shock Mechanical durability 1,000 m/s2 (approx. 100 G) Ambient temperature Malfunction durability 200 m/s2 (approx. 20 G), 100 m/s2 (approx. 10 G) for high-sensitive type Operating/storage -25 to 70C ("-H1" versions) with no icing -25 to 65C (standard versions) with no icing Humidity Service life 5% to 85% RH Mechanical 15 million operations min. (at operating frequency of 36,000 operations/hour) Electrical 100,000 operations min. (at 1,800 operations/hr), standard models. See "Characteristic Data" Weight Note: 1. 2. 3. 4. 64 Approx. 5 g The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method. Values in parentheses are typical values unless otherwise stated. The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those for checking the dielectric strength. The above values are initial values. Low Signal Relay G5V-2 Characteristic Data G5V-2 30-VDC resistive load 125-VAC resistive load 1 Rated operating voltage (V) Note: Ambient Temperature vs. Maximum Coil Voltage Maximum coil voltage (%) AC resistive load DC resistive load Electrical Service Life Service Life (x10 3 operations) Rated operating current (A) Maximum Switching Capacity 2 Coil rated voltage 3 to 24 VDC 48 VDC 3 Rated operating current (A) Ambient temperature () The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. G5V-2-H1 Maximum Switching Capacity Electrical Service Life 1000 AC resistive load 1 0.7 0.5 DC resistive load 0.2 0.1 500 200 24-VDC resistive load 300 100 125-VAC resistive load 50 30 10 Maximum coil voltage (%) 3 Service life (x10 3 operations) Rated operating current (A) 5 0.3 Ambient Temperature vs. Maximum Coil Voltage 3 to 24 VDC 180 160 140 48 VDC 120 100 80 0 0 Rated operating voltage (V) Note: Rated operating current (A) Ambient temperature () The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. Low Signal Relay G5V-2 65 Dimensions Note: 1. All units are in millimeters unless otherwise indicated. 2. Tolerance: 0.1 3. Orientation marks are indicated as follows: G5V-2, G5V-2-H1 Terminal Arrangement/ Internal Connections (Bottom View) 1 8 4 6 13 11 Mounting Holes (Bottom View) Tolerance: 0.1 (1.3) 7.62 5.08 5.08 (1.2) 10.1 max. 9.9 typ. 20.5 max. 20.3 typ. 7.62 16 9 (1.3) 11.5 max. 11.4 typ. Eight, 1-dia. holes 0.5 0.5 0.3 7.62 3.5 Approvals UL Recognized (File No. E41515) / CSA Certified (File No. LR31928) - - Ambient Temp. = 40C Type G5V-2 Contact form DPDT G5V-2-H1 Coil rating Contact ratings 3 to 48 VDC 0.6 A at 125 VAC (General Use) 0.6 A at 110 VDC (Resistive) 2 A at 30 VDC (Resistive) 3 to 48 VDC 0.5 A at 125 VAC (General Use) 0.2 A at 110 VDC (Resistive) 1 A at 24 VDC (Resistive) Note: 1. The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in this catalog. 2. In the interest of product improvement, specifications are subject to change. Precautions Long-term Continuously ON Contacts Relay Handling Using the Relay in a circuit where the Relay will be ON continuously for long periods (without switching) can lead to unstable contacts because the heat generated by the coil itself will affect the insulation, causing a film to develop on the contact surfaces. Be sure to use a fail-safe circuit design that provides protection against contact failure or coil burnout. When washing the product after soldering the Relay to a PCB, use a water-based solvent or alcohol-based solvent, and keep the solvent temperature to less than 40C. Do not put the Relay in a cold cleaning bath immediately after soldering. 66 Low Signal Relay G5V-2 MEMO Low Signal Relay G5V-2 All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ON-LINE OMRON ELECTRONIC COMPONENTS LLC 55 E. Commerce Drive, Suite B Schaumburg, IL 60173 Global - http://www.omron.com USA - http://www.components.omron.com 847-882-2288 Cat. No. X301-E-1b Low Signal Relay 09/11 G5V-2 Specifications subject to change without notice Printed in USA