BXA40 Series Triple output DC/DC CONVERTERS 40W Wide Input DC/DC Converters 1 * Meets telecom power supply interface standard ETS300-132-2 * EN60950, CSA950 and UL1950 safety approvals * EN61000-4-2, -3, -4, -5, -6 immunity compliant * Fixed frequency operation at 400kHz * MTBF in excess of 500,000 hours * Basic insulation system with 1500V isolation * Pin-compatible with NFC40 Series The BXA40-48T05-12-M provides 40 Watts of output power, has been conceived as an applications-specific range of DC/DC converters, specifically addressing telecommunications, industrial electronics, test equipment, mobile telecommunications and distributed power applications. The series offers a wide input voltage range, of 3675VDC, and is available with a 5/12V triple output. The BXA40 series is designed to meet ETSI telecoms interface standard ETS300-132-2. With safety approval to IEC950 and basic insulation, the 48VDC model is ideal for telecommunications applications. Other features include low output ripple, overvoltage protection, short circuit protection and remote enable. 2 YEAR WARRANTY SPECIFICATIONS All specifications are typical at nominal input, full load at 25C unless otherwise stated OUTPUT SPECIFICATIONS EMC CHARACTERISTICS Line regulation (See Note 2) Main output Auxiliary output 0.5% 2.0% Load regulation (See Note 3) Main output Auxiliary output 1.0% 3.0% typ., 5.0% max. Load cross regulation (See Note 4) Main output Aux. output 1.0% 3.0% typ., 5.0% max. Ripple and noise (20MHz bandwidth) Main output 50mV pk-pk, 20mV rms 100mV pk-pk, 20mV rms Auxiliary output Temperature coefficient 0.02%/C Overvoltage protection transorbs fitted Main output Auxiliary outputs Short circuit protection (See Note 5) Main output Auxiliary output Transient response 25% to 100% load Voltage accuracy Main output Auxiliary output Minimum Load Main output Auxiliary outputs 6.8V (nom.) 16/20V (nom.) 11A 5A 4.0% 1.0% 3.0% 0.6A 0.03A/0.04A Input voltage range 48Vin nominal 36 to 75VDC Reverse voltage protection External fuse (See Note 7) Start-up time Remote ON/OFF Logic compatibility ON OFF Radiated emissions ESD air ESD contact Surge Fast transients Radiated immunity Conducted immunity 5V/ms ETS300-132 30ms typ. CMOS/TTL Open-circuit <1VDC EN55022, FCC part 15, (See Notes 6, 9) EN55022, FCC part 15 EN61000-4-2, level 3 EN61000-4-2, level 4 EN61000-4-5, level 3 EN61000-4-4, level 3 EN61000-4-3, level 3 EN61000-4-6, level 3 Level B Perf. Perf. Perf. Perf. Perf. Perf. Level A criteria 1 criteria 1 criteria 1 criteria 1 criteria 1 criteria 1 GENERAL SPECIFICATIONS Efficiency 83% Isolation voltage Input/output Basic insulation, input/case Switching frequency Fixed 1500VDC 1500VDC 400kHz (typical) Approvals and standards (pending) EN60950, UL1950 CSA C22.2 No. 950 Case material Aluminum substrate with plastic case Material flammability UL94V-0 Weight MTBF INPUT SPECIFICATIONS Max. input rise and fall time Conducted emissions 85g typ. (3.0oz) MIL-HDBK-217F Size 500,000 hours 2.2 x 2.2 x 0.5 inches 55.9 x 55.9 x 12.7 mm ENVIRONMENTAL SPECIFICATIONS Thermal performance Thermal impedance (See Note 8) Baseplate operating temperature Non-operating -40C to +105C -55C to +105C No air flow, no heatsink No air flow, with heatsink 8.5C/W 7.2C/W File Name: BXA40T.PDF Rev: 02 Oct 2002 BXA40 Series Triple output DC/DC CONVERTERS 40W Wide Input DC/DC Converters 2 For the most current data and application support visit www.artesyn.com/powergroup/products.htm INPUT VOLTAGE OUTPUT VOLTAGE OUTPUT CURRENT (MAX.) 36-75VDC 5V/12V 6A/0.4A INPUT CURRENT TYPICAL EFFICIENCY (1) 30mA MODEL NUMBER 83% Notes (10) BXA40-48T05-12-M PIN CONNECTIONS 1 2 3 Nominal line, at no load. Nominal line to high line, nominal line to low line. Load regulation: Main output (V1): 25 to 100% with 25% to 100% balanced on auxiliaries. Auxiliary outputs (V2 and V3): 25% to 100% balanced on all outputs. 4 Cross regulation: Main output 100% load, auxiliary 100%, other auxiliary 25% to 100%. Auxiliary outputs (V2 and V3): main output 100% load, auxiliary 100%, other auxiliary 25% to 100% or main output 25%, auxiliary 25%, other auxiliary 25% to 100%. 5 Short circuit protection, 1 minute on auxiliary outputs. 6 For EMI compliance to EN55022 level B please consult factory for details. For EMI compliance to EN55022 level A, refer to BXA40 Design Note 101. 7 Reverse voltage protection, refer to BXA40 Design Note 101. 8 The maximum operating ambient temperature, without derating depends on internal power dissipation and module efficiency and cooling method. Download BXA40 Design Note 101 which provides detailed thermal calculations and design-in hints from the Artesyn website. 9 It is suggested that an external filter capacitor be used. A 4F (or greater) film capacitor such as: ITW Paktron Capstick series, part number 405K100CS4 4F/100V is recommended, if filtering is not used. See BXA40 Design Note 101. 10 The unit with the suffix `-M' at the end of the model number is offered as standard with metric threaded inserts (M3). To order a unit with imperial threaded inserts (4-40 UNC) please remove the suffix `-M' from the model number. These inserts are used for bolting the unit to a PCB and/or fixing heatsinks. 11 A top mounted heatsink kit is available for the BXA40. The heatsink may be oriented parallel to or perpendicular to the direction of the pins, thus providing 0.019 optimum flexibility for cooling requirements. The order (0.50) number for the top mounted heatsink kit with metric screws is `NFC40-HTSK-T'. The order number for the top mounted heatsink kit with imperial screws is `NFC40-HTSK-T-I'. PIN NUMBER TRIPLE OUTPUT 1 + Input 2 - Input 3 Control 4 + Output (V2) 5 Common 6 - Output (V3) 7 + Output (V1) 8 - Output (V1) 9 No Connection 1.90 (48.26) 0.15 (3.82) 1.25 (31.76) 0.60 (15.24) 0.2 (5.08) 3 2 1 0.043 0.003(1.02 0.05) Diameter Typ. Metric (Suffix '-M'): M3 Tap Thru. 4 places or Imperial (No '-M' suffix) 440 UNC (Optional) 1.80 (45.72) 1.90 (48.26) 2.20 0.02 (55.90 0.50) 0.256 (6.50) Diameter Stand-off (4 Places) 9 0.50 (12.70) 8 7 6 0.15 (3.90) International Safety Standard Approvals VDE0805/EN60950/IEC950 File No. 14501-3336-7009 Licence No. 6296 UL1950 File No. E174104 0.3 (7.62) 5 4 0.1 (2.54) 0.2 (5.08) 0.05 (1.27) 0.15 (3.82) 0.6 (15.24) 0.8 0.5 (20.32) (12.70) 2.20 0.02 (55.90 0.50) BOTTOM VIEW ALL DIMENSIONS IN INCHES (mm) TOLERANCE : 0.004 (0.1) (Unless otherwise specified) CSA C22.2 No. 950 File No. LR41062C Data Sheet (c) Artesyn Technologies(R) 2002 The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein. Please consult our website for the following items: Design Note www.artesyn.com File Name: BXA40T.PDF Rev: 02 Oct 2002