a division of CUI INC
date
page
SERIES: DESCRIPTION:
11/2009
2 of 4
SWITCHING POWER SUPPLY
12 W WALL PLUG
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382 www.v-infi nity.com
INPUT
parameter conditions/description min nom max units
rated input voltage 100 240 V ac
input voltage range 90 264 V ac
rated frequency 50 60 Hz
frequency range 47 63 Hz
inrush current 50 A
no load power consumption 100 ~ 240 V ac input 0.5 W
OUTPUT
parameter conditions/description min nom max units
line regulation ±2 %
load regulation ±5 %
temp. coefficient 0.05 %/°C
start-up time at 110 V ac, full load 2s
hold-up time at 110 V ac, full load 10 ms
over voltage protection 125% 180% V dc
overload protection Overload results in decreased output voltage until
auto-recovery once the over load is removed.
short circuit protection auto-recovery
SAFETY & EMI
parameter conditions/description min nom max units
HI-POT input to output at 4 mA for 2 seconds
input to case at 4 mA for 2 seconds
3000
3000
V ac
V ac
insulation resistance input to output at 500 V dc 50 M
safety approvals UL/cUL (60950-1)
EMI standard FCC part 15 class B
RoHS compliant yes
LPS power supply yes
ENVIRONMENTAL
parameter conditions/description min nom max units
operating temperature 040°C
operating humidity 10 95 %
storage temperature -20 70 °C
storage humidity 10 95 %
RELIABILITY
parameter conditions/description min nom max units
MTBF at 25°C 50,000 hours