a division of CUI INC
date
page
SERIES: DESCRIPTION:
11/2009
1 of 4
SWITCHING POWER SUPPLY
12 W WALL PLUG
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382 www.v-infi nity.com
FEATURES
•universal AC input
•regulated output voltage
•short circuit, over load protection
•meets EISA / efficiency level IV regulations
•custom designs available
MODEL output voltage output current output wattage ripple* efficiency level cord length
nominal
(V dc)
min
(A)
max
(A)
max
(W)
max.
(mVp-p)
(mm)
EPS050250UPS-P5P-KH 5 0 2.5 12.5 80 IV 1800 ±30
EPS060175UPS-P5P-KH 6 0 1.75 10.5 80 IV 1800 ±30
EPS090120UPS-P5P-KH 9 0 1.2 10.8 90 IV 1800 ±30
EPS120100UPS-P5P-KH 12 0 1.0 12 120 IV 1800 ±30
EPS150080UPS-P5P-KH 15 0 0.8 12 150 IV 1800 ±30
EPS180067UPS-P5P-KH 18 0 0.67 12.1 180 V 1800 ±30
EPS240050UPS-P5P-KH 24 0 0.5 12 240 IV 1800 ±30
*full load, 100~240 Vac input, measured at 20MHz bandwidth with a 22 uF electrolytic cap and a 0.1 uF ceramic cap on the output
RoHS
a division of CUI INC
date
page
SERIES: DESCRIPTION:
11/2009
2 of 4
SWITCHING POWER SUPPLY
12 W WALL PLUG
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382 www.v-infi nity.com
INPUT
parameter conditions/description min nom max units
rated input voltage 100 240 V ac
input voltage range 90 264 V ac
rated frequency 50 60 Hz
frequency range 47 63 Hz
inrush current 50 A
no load power consumption 100 ~ 240 V ac input 0.5 W
OUTPUT
parameter conditions/description min nom max units
line regulation ±2 %
load regulation ±5 %
temp. coefficient 0.05 %/°C
start-up time at 110 V ac, full load 2s
hold-up time at 110 V ac, full load 10 ms
over voltage protection 125% 180% V dc
overload protection Overload results in decreased output voltage until
auto-recovery once the over load is removed.
short circuit protection auto-recovery
SAFETY & EMI
parameter conditions/description min nom max units
HI-POT input to output at 4 mA for 2 seconds
input to case at 4 mA for 2 seconds
3000
3000
V ac
V ac
insulation resistance input to output at 500 V dc 50 M
safety approvals UL/cUL (60950-1)
EMI standard FCC part 15 class B
RoHS compliant yes
LPS power supply yes
ENVIRONMENTAL
parameter conditions/description min nom max units
operating temperature 040°C
operating humidity 10 95 %
storage temperature -20 70 °C
storage humidity 10 95 %
RELIABILITY
parameter conditions/description min nom max units
MTBF at 25°C 50,000 hours
a division of CUI INC
date
page
SERIES: DESCRIPTION:
11/2009
3 of 4
SWITCHING POWER SUPPLY
12 W WALL PLUG
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382 www.v-infi nity.com
MECHANICAL DRAWING
5.5
2.1
refer to Cable
Gauge table
EPS240050
EPS180670
EPS150080
EPS120100
EPS090120
EPS060175
EPS050250
24 AWG
24 AWG
Cable Gauge
22 AWG
22 AWG
22 AWG
20 AWG
18 AWG
12
a division of CUI INC
date
page
SERIES: DESCRIPTION:
11/2009
4 of 4
SWITCHING POWER SUPPLY
12 W WALL PLUG
20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382 www.v-infi nity.com
INDIVIDUAL PACKAGING
(Transverse Plane)
410
270
310
100V~240V
200V~240V
100V~120V
MODEL:
N.W.:
G.W.:
Q'TY: 100PCS
100V~120V
100V~240V
200V~240V
PACKAGING