C-141
Connector type/2 outputs
DC-AC Inverter
・Allspecificationsaresubjecttochangewithoutnotice.
CXA-0508
CXA-0508Specifications (Please refer to each specification before use)
Dimming
Function Yes
Operating
Temperature ℃ -10to+60
Storage
Temperature ℃ -30to+85
Operating
Humidity Ratio RH% 95max.
Safety
Standard ー
Weight g 27typ.
Dimensions
(WxDxH)
mm 130x40x9.5(*4)
Fused Input Yes
Remote ON / OFF
Yes
Alarm Signal
Function
Yes
Shutdown
Function
Yes
Silicone Coating on
High Voltage Area
Yes
Item Unit Symbol Specifi cation Condition
min typ max Vin(V) Vrmt(V) Vbr(V) Rbr(kΩ) Ta(℃)
RL1,2(kΩ)
CL1,2(pF)(*3)
Remarks
Output Current mArms
lout 1, 2
(Maximum
dimmer)
6.0 6.5 7.0
12±0.6
5 2.5 -
-10to+60
110 5 Voltage
dimmer (*1)
6.0 6.5 7.0
12±0.6
5-50
-10to+60
110 5 Volume
dimmer (*1)
lout 1, 2
(
Minimum
dimmer
)
2.1 3.0 3.9
12±0.6
50 -
-10to+60
110 5 Voltage
dimmer (*1)
2.1 3.0 3.9
12±0.6
5-0
-10to+60
110 5 Volume
dimmer (*1)
Input Current A Iin1 - 0.9 2.0
12±0.6
5 2.5 50
-10to+60
110 5 Remote ON
mA Iin2 - 0 1
12±0.6
0 2.5 50
-10to+60
110 5 Remote OFF
Oscillatory
Frequency
kHz Freq1 45 55 65
12±0.6
5 2.5 50
-10to+60
110 5
Hz
Freq2 (Duty frequency)
148 168 188
12±0.6
500
-10to+60
110 5
Open Circuit
Voltage Vrms Vopen 1500 1800 -
12±0.6
5 2.5 50
-10to+60
∞∞
Open load
AlarmSignal V Vst
- 0 0.5
12±0.6
5 2.5 50
-10to+60
∞∞
In case of
lamp anomaly
(*2)
2.5 3 3.5
12±0.6
5 2.5 50
-10to+60
110 5 On a normal
operation (*2)
Electrical Characteristics
Other Specifications
■Features
●2 outputs
●Applicablepanelsize*:15inches
●
Withbrightnesscontrolfunction(PulseWidthModulationDimming)
.
●Withshutdownfunction.
●Withasensingfunctionforrunningoutoflamp(alarmoutput).
●Inthehigh-voltagegenerator(aterminalandapattern),ananti-dust
measurebysiliconeapplicationistaken.
(Notice)Applicablepanelsizebecomesastandard.
■Applications
F A MED MEASURE
(*4) These dimensions are indicated the maximum only H. Others are typical values.
(*1) Please refer to the connection diagram for details of a dimming method.
(*2) Initial status of alarm output is 0V, and after return current detection of output, 3V are output to CN1-6.
When load (lamp) is open, and when GND has shorted, 0V will be output to CN1-6.
(*3)
Asequivalentcircuitofpanelload,connectresistanceload(RL)anddistributedcapacity(CL),andhaveprovidedbyanelectricalcharacteristic.
Dimming/Connector Type
This means that, in conformity with EU Directive
2002/95/EC, lead, cadmium, mercury, hexavalent
chromium, and specific bromine-based flame
retardants, PBB and PBDE, have not been used,
except for exempted applications.
■
Conformity to RoHs Directive