Versatile Filtered Power Entry Module
Approvals■ Rated currents up to 6A
■ Single or dual-fuse holder
■ Fuses Ø6.3 x 32mm or Ø5 x 20mm
■ Voltage selector 100/120/230/240V
■ General purpose application
■ Optional medical versions (B type)
Typical applications
The FN 370 power entry module combines an
IEC inlet, a mains filter with a single or dual-
fuse holder and a voltage selector. Choosing
FN 370 product line brings you the rapid
availability of a standard filter associated with
the necessary safety acceptances. Standard
IEC connector filters are a practical solution
helping you to pass EMI system approval in
a short time. A wide selection on amperage
ratings, fuse options, mounting possibilities
and filters for medical applications are
designed to offer you the desired solution.
■ Good conducted attenuation performance,
based on chokes with high saturation
resistance and excellent thermal behavior.
■ Rear/front or snap-in mounting.
■ Single or dual-fuse holder.
■ USA Ø6.3 x 32mm or EU Ø5 x 20mm fuses.
■ Two attenuation performance ranges.
■ Voltage selector 100/120/230/240V.
■ Custom-specific versions are available on
request.
■ Portable electrical and electronic
equipment
■ Consumer goods
■ EDP and office equipment
■ Single-phase power supplies, switch-mode
power supplies
■ Test and measurement equipment
■ Medical equipment
Features and benefits
Technical specifications
Maximum continuous operating voltage: 250VAC, 50/60Hz
Operating frequency: dc to 400Hz
Rated currents: 2 to 6A @ 40°C max.
High potential test voltage: P –> PE 2000VAC for 2 sec (standard types)
P –> PE 2500VAC for 2 sec (B types)
P –> N 760VAC for 2 sec
Protection category: IP40 according to IEC 60529
Temperature range (operation and storage): -25°C to +85°C (25/85/21)
Design corresponding to: UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
Flammability corresponding to: UL 94V-2 or better
MTBF @ 40°C/230V (Mil-HB-217F): 550,000 hours
Voltage selector description: VOL-SE 4SP-4
Function: Series/parallel
Voltage marking*:
1st: 100
2nd: 120
3rd: 230
4th: 240
Closed internal contact corresponding to:
1st: a, c, e
2nd: b, c, e
3rd: a, d
4th: b, d
Typical electrical schematic
* Other selected voltage marking on request.
N
PE
P
Line
Cx 2xL 2xCy
Load
M F E
L J G
FN 372 / FN 378 / FN 379
FN 370 / FN 376
C
A
D
B
e
d
c
b
a
Fuse
holder
Voltage selector
N
PE
P
Line
Cx 2xL 2xCy
Load
M F E
L J G
C
A
D
B
e
d
c
b
a
Fuse
holders
Voltage selector
K H
IEC Inlet Filters
FN 370