R
o
H
S
Telecom Design Guide • © 2006 Littelfuse 3 - 43 www.littelfuse.com
SIDACtor Devices
SIDACtor® Device
This modified TO-220 package with Type 61 lead spacing offers a through-hole technology
SIDACtor protection solution.
SIDACtor devices enable equipment to comply with various regulatory requirements
including GR 1089, ITU K.20, K.21 and K.45, IEC 60950, UL 60950, and TIA-968-A
(formerly known as FCC Part 68).
* “L” in part number indicates RoHS compliance. For non-RoHS compliant device, delete “L” from part number.
For surge ratings, see table below.
General Notes:
• All measurements are made at an ambient temperature of 25 °C. IPP applies to -40 °C through +85 °C temperature range.
• IPP is a repetitive surge rating and is guaranteed for the life of the product.
• Listed SIDACtor devices are bi-directional. All electrical parameters and surge ratings apply to forward and reverse polarities.
• VDRM is measured at IDRM.
• VS is measured at 100 V/µs.
• Special voltage (VS and VDRM) and holding current (IH) requirements are available upon request.
* Current waveform in µs
** Voltage waveform in µs
Electrical Parameters
Part
Number *
VDRM
Volts
VS
Volts
VT
Volts
IDRM
µAmps
IS
mAmps
IT
Amps
IH
mAmps
P2000AA61L 180 220 4 5 800 2.2 150
P2200AA61L 200 240 4 5 800 2.2 150
P2400AA61L 220 260 4 5 800 2.2 150
P2500AA61L 240 290 4 5 800 2.2 150
P3000AA61L 270 330 4 5 800 2.2 150
P3300AA61L 300 360 4 5 800 2.2 150
Surge Ratings in Amps
Series
IPP
ITSM
50 / 60 Hz di/dt
0.2x310 *
0.5x700 **
2x10 *
2x10 **
8x20 *
1.2x50 **
10x160 *
10x160 **
10x560 *
10x560 **
5x320 *
9x720 **
10x360 *
10x360 **
10x1000 *
10x1000 **
5x310 *
10x700 **
Amps Amps Amps Amps Amps Amps Amps Amps Amps Amps Amps/µs
A 20 150 150 90 50 75 75 45 75 20 500