Surge arrester
2-electrode arrester
Series/Type: M50-C90XSMD
Ordering code: B88069X1640T902
Date: 2016-02-04
Version: 13
EPCOS AG 2016. Reproduction, publication and dissemination of this publication, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited.
EPCOS AG is a TDK Group Company.
Content of header bars 1 and 2 of data sheet will be
automatically
entered in headers and footers! Please fill in the table and then
change the color to "white". This ensures that the table disappears (invisible) for the customer PDF.
Don't change formatting when entering or pasting text in the table and don't add any cell or line in and to it!
Identification/Classification 1
(header 1 + top left bar): Surge arrester
Identification/Classification 2
(header 2 + bottom left header bar): 2-electrode arrester
Ordering code: (top right header bar) B88069X1640T902
Series/Type: (bottom right header bar) M50-C90XSMD
Preliminary data (optional):
Department: PPD AB PD / PPD AB PM
Date: 2016-02-04
Version: 13
Surge arrester B88069X1640T902
2-electrode arrester M50-C90XSMD
PPD AB PD / PPD AB PM 2016-02-04
Please read Cautions and warnings and Page 2 of 5
Important notes at the end of this document.
Features Applications
Very small size
High current rating
Very fast response time
Stable performance over life
Very low capacitance
High insulation resistance
Excellent SMD handling
RoHS-compatible
Modem
XDSL-splitter
Data lines
Tuner
Antenna
Electrical specifications
DC spark-over voltage
1) 2)
Tolerance
Min.
Max.
90
±20
72
108
V
%
V
V
Impulse spark-over voltage
at 100 V/µs - for 99% of measured values
- typical values of distribution
at 1 kV/µs - for 99% of measured values
- typical values of distribution
< 550
< 500
< 600
< 550
V
V
V
V
Service life
10
operations 50 Hz, 1 s
5 A
1
operations 50 Hz, 0.18 s (9 cycles) 10 A
10
operations 8/20 µs 5 kA
1
operation 8/20 µs 10 kA
1
operation 10/350 µs 0.5 kA
300
operations 10/1000 µs 100 A
Insulation resistance at 50 VDC > 1 G
Capacitance at 1 MHz < 1
pF
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
~ 10
< 0.7
~ 55
V
A
V
Weight ~ 1 g
Operation and storage temperature 40 ... +125 °C
Climatic category (IEC 60068-1) 40/125/21
Marking, blue negative
90 YY O
90 - Nominal voltage
YY - Year of production
O - Non radioactive
Certification UL 497B (E163070)
1) At delivery AQL 0.65 level II, DIN ISO 2859
2) In ionized mode
Terms in accordance with ITU-T Rec. K.12; IEC 61663-2 and IEC 61643-311.
Surge arrester B88069X1640T902
2-electrode arrester M50-C90XSMD
PPD AB PD / PPD AB PM 2016-02-04
Please read Cautions and warnings and Page 3 of 5
Important notes at the end of this document.
Dimensional drawing in mm
Ordering code and packing advice
B88069X1640T902 = 900 pcs. on SMD-tape
Surge arrester B88069X1640T902
2-electrode arrester M50-C90XSMD
PPD AB PD / PPD AB PM 2016-02-04
Please read Cautions and warnings and Page 4 of 5
Important notes at the end of this document.
Soldering parameter
Reflow soldering
Reflow profile
features Sn- Pb eutectic
assembly Pb-free
assembly
Preheat and soak
- Temperature min
- Temperature max
- Time
Tsmin
Tsmax
tsmin to tsmax
100 °C
150 °C
60 ... 120 s
150 °C
200 °C
60 ... 180 s
Average ramp-up
rate Tsmax to Tp max. 3 °C/ s max. 3 °C/ s
Liquidous
temperature
Time at liquidous
TL
tL
183 °C
60 ... 150 s
217 °C
60 ... 150 s
Peak package body
temperature *,
Classification
temperature **
Tp, TC 220 ... 235 °C ** 245 ... 260 °C **
Time (tp) ** within
5 °C of the specified
classification
temperature (TC)
20 s *** 30 s ***
Average ramp-down
rate Tp to Tsmax max. 6 °C/ s max. 6 °C/ s
Time 25 °C to peak
temperature max. 6 min max. 8 min
* = Tolerance for peak profile temperature (Tp) is defined as a supplier minimum and
a user maximum.
** = For details please refer to JEDEC J-STD-020D.
*** = Tolerance for time at peak profile temperature (tp) is defined as a supplier
minimum and a user maximum.
Surface mounted components (SMD) may exhibit a temporary increase in the DC spark-over voltage after the solder reflow
process. The components will recover within 24 hours. There is no quality defect nor change in protection levels during the
temporary change in DC spark-over voltage.
Cautions and warnings
Do not operate surge arresters in power supply networks, whose maximum operating voltage
exceeds the minimum spark-over voltage of the surge arresters.
Surge arresters may become hot in the event of longer periods of current stress (burn risk). In the
event of overload the connectors may fail or the component may be destroyed.
If the contacts of the surge arresters are defective, current load can cause sparks and loud
noises.
Surge arresters must be handled with care and must not be dropped.
Do not continue to use damaged surge arresters.
Display of ordering codes for EPCOS products
The ordering code for one and the same EPCOS product can be represented differently in data
sheets, data books, other publications, on the EPCOS website, or in order-related documents such as
shipping notes, order confirmations and product labels. The varying representations of the
ordering codes are due to different processes employed and do not affect the specifications of
the respective products. Detailed information can be found on the Internet under
www.epcos.com/orderingcodes
Page 5 of 5
Important notes
The following applies to all products named in this publication:
1. Some parts of this publication contain statements about the suitability of our products for certain areas
of application. These statements are based on our knowledge of typical requirements that are often placed
on our products in the areas of application concerned. We nevertheless expressly point out that such
statements cannot be regarded as binding statements about the suitability of our products for a
particular customer application. As a rule we are either unfamiliar with individual customer applications or
less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent
on the customer to check and decide whether a product with the properties described in the product
specification is suitable for use in a particular customer application.
2. We also point out that in individual cases, a malfunction of electronic components or failure before
the end of their usual service life cannot be completely ruled out in the current state of the art, even
if they are operated as specified. In customer applications requiring a very high level of operational safety
and especially in customer applications in which the malfunction or failure of an electronic component could
endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be
ensured by means of suitable design of the customer application or other action taken by the customer (e.g.
installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the
event of malfunction or failure of an electronic component.
3. The warnings, cautions and product-specific notes must be observed.
4. In order to satisfy certain technical requirements, some of the products described in this publication
may contain substances subject to restrictions in certain jurisdictions (e.g. because they are
classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet
(www.tdk-electronics.tdk.com/material). Should you have any more detailed questions, please contact our
sales offices.
5. We constantly strive to improve our products. Consequently, the products described in this publication
may change from time to time. The same is true of the corresponding product specifications. Please
check therefore to what extent product descriptions and specifications contained in this publication are still
applicable before or when you place an order.
We also reserve the right to discontinue production and delivery of products. Consequently, we
cannot guarantee that all products named in this publication will always be available. The aforementioned
does not apply in the case of individual agreements deviating from the foregoing for customer-specific
products.
6. Unless otherwise agreed in individual contracts, all orders are subject to our General Terms and
Conditions of Supply.
7. Our manufacturing sites serving the automotive business apply the IATF 16949 standard. The IATF
certifications confirm our compliance with requirements regarding the quality management system in the
automotive industry. Referring to customer requirements and customer specific requirements (“CSR”) TDK
always has and will continue to have the policy of respecting individual agreements. Even if IATF 16949
may appear to support the acceptance of unilateral requirements, we hereby like to emphasize that only
requirements mutually agreed upon can and will be implemented in our Quality Management
System. For clarification purposes we like to point out that obligations from IATF 16949 shall only become
legally binding if individually agreed upon.
8. The trade names EPCOS, CeraCharge, CeraDiode, CeraLink, CeraPad, CeraPlas, CSMP, CTVS,
DeltaCap, DigiSiMic, ExoCore, FilterCap, FormFit, LeaXield, MiniBlue, MiniCell, MKD, MKK, MotorCap,
PCC, PhaseCap, PhaseCube, PhaseMod, PhiCap, PowerHap, PQSine, PQvar, SIFERRIT, SIFI, SIKOREL,
SilverCap, SIMDAD, SiMic, SIMID, SineFormer, SIOV, ThermoFuse, WindCap are trademarks registered
or pending in Europe and in other countries. Further information will be found on the Internet at www.tdk-
electronics.tdk.com/trademarks.
Release 2018-10