Parameters IRK.170 IRK.230 IRK.250 Units Conditions
IT(AV) Maximum average on-state current 170 230 250 A 180o conduction, half sine wave
@ Case temperature 85 85 85 oC
IT(RMS) Maximum RMS on -state current 377 510 555 A as AC switch
ITSM Maximum peak, one-cycle on-state, 5100 7500 8500 A t = 10ms No voltage
non-repetitive surge current 5350 7850 8900 t = 8.3ms reapplied
4300 6300 7150 t = 10ms 100% VRRM
4500 6600 7500 t = 8.3ms reapplied Sinusoidal half wave,
I2t Maximum I2t for fusing 131 280 361 KA2s t = 10ms No voltage initial TJ = TJ max
119 256 330 t = 8.3ms reapplied
92.5 198 255 t = 10ms 100% VRRM
84.4 181 233 t = 8.3ms reapplied
I2√t Maximum I2√t for fusing 1310 2800 3610 KA2√s t = 0.1 to 10ms, no voltage reapplied
VT(TO)1Low level value of threshold voltage 0.89 1.03 0.97 V (16.7% x π x IT(AV) < I < π x IT(AV)), TJ = TJ max.
VT(TO)2High level value of threshold voltage 1.12 1.07 1.00 (I > π x IT(AV)), TJ = TJ max.
rt1 Low level on-state slope resistance 1.34 0.77 0.60 mΩ(16.7% x π x IT(AV) < I < π x IT(AV)), TJ = TJ max.
rt2 High level on-state slope resistance 0.96 0.73 0.57 (I > π x IT(AV)), TJ = TJ max.
ITM = π x IT(AV), TJ = TJ max., 180o conduction
Av. power = VT(TO) x IT(AV) + rf
x (IT(RMS))2
IHMaximum holding current 500 500 500 mA Anode supply=12V, initial IT=30A, TJ=25oC
ILMaximum latching current 1000 1000 1000 Anode supply=12V, resistive load=1Ω
gate pulse: 10V, 100µs, TJ = 25°C
Type number Voltage VRRMVDRM , maximum VRSM , maximum non-repetitive IRRM IDRM max
Code repetitive peak reverse and peak reverse voltage @ 130°C
off-state blocking voltage
VVm A
04 400 500 50
IRK.170- 08 800 900
IRK.250- 12 1200 1300
14 1400 1500
16 1600 1700
IRK.230- 08 800 900 50
12 1200 1300
16 1600 1700
18 1800 1900
20 2000 2100
tdTypical delay time 1.0 µsT
J = 25oC, Gate Current=1A dIg/dt=1A/µs
trTypical rise time 2.0 Vd = 0,67% VDRM
ITM = 300 A ; -dI/dt=15 A/µs; TJ = TJ max ;
Vr = 50 V; dV/dt = 20 V/µs ; Gate 0 V, 100 ohm
Voltage Ratings
ELECTRICAL SPECIFICATIONS
On-state Conduction
Switching
tqTypical turn-off time 50 - 150 µs
VTM Maximum on-state voltage drop 1.60 1.59 1.44 V