AC Output Modules FEATURES * Transient Protection: Meets the requirements of IEEE 472, "Surge Withstanding Capability Test" * SPST, Normally Open * Zero Crossing Turn-On * UL, CSA, CE, TUV Certified * Optical Isolation * OpenLine(R) and G5 Modules Provide Replaceable 5x20 mm Glass Fuses * Built-in Status LED * Lifetime Warranty 70L-OAC 4 LOAD CURRENT (AMPS) DIMENSIONS For complete dimensional drawings, see pages L-4 or L-5. FUSES G5 Fuses are 5 Amp Littelfuse part number 217005 or equivalent. OpenLine(R) fuses are 3.15 Amp Littelfuse part number 2173.15. 3 2 70G-OAC 70-OAC 70M-OAC Maximum Current Versus Ambient Temperature The chart indicates continuous current to limit the junction temperatures to 100C. Information is based on steady state heat transfer in a 2 cubic foot sealed enclosure. STANDARD, G5 PACKAGES MINIATURE PACKAGE OPENLINE PACKAGE/CH 1 -40 -20 0 20 40 60 80 AMBIENT TEMPERATURE (C) 100 Figure 1 CIRCUITRY OpenLine(R) Standard, Mini, G5 LOAD TYPICAL WIRING FOR MODULE 0 VAC SNUBBER LOAD 2 GND 5 Vcc 6 CHANNEL A A TRIGGER CIRCUIT CH. A CONTROL Rx OPTICAL ISOLATION CH. B CONTROL 3 1 1 2 2 3 3 4 4 LOAD SNUBBER SNUBBER LOAD CHANNEL B DC CONTROL - OPTICAL ISOLATION 7 B + I/O MODULE PIN # 1 2.15K 4 MODULE ID RACK OR BASE MODULE Fuse and status LED in G5 and OpenLine modules only. TERMINAL BLOCK # I/O Modules SPECIFICATIONS: By Package Style Package Style Specifications Load Current Range Maximum 1 Cycle Surge 2 Maximum Turn-On-Time (60 Hz)3 Maximum Turn-Off Time (60 Hz) Static dv/dt7 Typ. Power Dissipation Isolation Voltage 4 Vibration5 Mechanical Shock6 Storage Temp. Range Operating Temp. Range Warranty 2 3 4 5 6 7 Mini (70M-) G5 (70G-) OL (70L-) 0.03 to 3.5 80 8.33 8.33 3000 1.0 4000 MIL-STD-202 MIL-STD-202 -40 to 125 -40 to 100 Lifetime 0.03 to 3.0 80 8.33 8.33 3000 1.0 4000 MIL-STD-202 MIL-STD-202 -40 to 125 -40 to 100 Lifetime 0.03 to 3.5 80 8.33 8.33 3000 1.0 4000 MIL-STD-202 MIL-STD-202 -40 to 125 -40 to 100 Lifetime 0.03 to 2.0/CH 30 8.33 8.33 3000 1.0 2500 IEC68-2-6 IEC68-2-27 -40 to 100 -40 to 85 Lifetime Units 1 1 Std (70-) A rms A rms mSec mSec V/sec W/A V rms C C See Figure 1 for derating. Maximum 10 cycle surge is 50% of 1 cycle surge. Application of maximum surge may not be repeated until module temperature has returned to its steady state value. Except 70-OAC5A5 which is 200 Sec and 70-OAC5A-11, 70M-OAC5A-11, and 70G-OAC5A-11 which are 100 Sec. Field to logic and channel-to-channel if Grayhill racks are used. MIL-STD-202, Method 204, 20 , 10-2000 Hz or IEC68-2-6, 0.15 mm/sec2, 10-150 Hz. MIL-STD-202, Method 213, Condition F, 1500G or IEC68-2-27, 11 mS, 15g. Except part numbers with -L suffix which have a dv/dt rating of 200 V/Sec. I/O 6 Grayhill, Inc. * 561 Hillgrove Avenue * LaGrange, Illinois 60525-5997 * USA * Phone: 708-354-1040 * Fax: 708-354-2820 * www.grayhill.com 762761&7.'5 SPECIFICATIONS: By Part Number Standard and Miniature Modules Type/Function Grayhill Part Number Miniature, Normally Open, Random Turn-on 70M-OAC5A-11 Miniature, Normally Open, Zero Voltage Turn-on (ZVT) 70M-OAC5 70M-OAC5A Miniature, Normally Open, ZVT, Inductive Load 70M-OAC5-L 70M-OAC5A-L Standard, Normally Closed, Random Turn-on 70-OAC5A5 Standard, Normally Open, Random Turn-on 70-OAC5A-11 Standard, Normally Open, ZVT 70-OAC5 70-OAC5A Standard, Normally Open, ZVT, Inductive Load 70-OAC5-L 70-OAC5A-L Specifications Nominal Line Voltage Load Voltage Range Minimum Peak Blocking Voltage Maximum Off-state Leakage @ 60Hz Nominal Logic Voltage (Vcc) Logic Voltage Range Max. Logic Supply Current @ Nominal Vcc Nominal Input Resistance (Rx) Minimum Drop Out Voltage Maximum Reverse Logic Voltage Units Vac Vac Volts mA, rms Vdc Vdc mA W Vdc Vdc 120 24-140 400 2 5 2.5-10 16 240 1 -5 70M-OAC15 70M-OAC24 70M-OAC24A 70-OAC24A-11 70-OAC15 240 24-280 600 4 5 2.5-10 16 240 1 -5 120 24-140 400 2 15 10-18 9 1800 1 -5 70-OAC15A 70-OAC24 70-OAC24A 240 24-280 600 4 15 10-18 9 1800 1 -5 120 24-140 400 2 24 15-30 9 2700 1 -5 240 24-280 600 4 24 15-30 9 2700 1 -5 70G-OAC24 70G-OAC24A G5 Modules Grayhill Part Number Type/Function G5 Fusible, Normally Open, ZVT 70G-OAC5 G5 Fusible, Normally Open, ZVT, Inductive Load 70G-OAC5-L 70G-OAC5A-L Specifications 70G-OAC5A 70G-OAC15 70G-OAC15-L 70G-OAC15A-L 120 24-140 400 2 15 8-20 12 1000 1 -5 240 24-280 600 4 15 8-20 12 1000 1 -5 Units Nominal Line Voltage Load Voltage Range Minimum Peak Blocking Voltage Maximum Off-state Leakage @ 60Hz Nominal Logic Voltage (Vcc) Logic Voltage Range Max. Logic Supply Current @ Nominal Vcc Nominal Input Resistance (Rx) Minimum Drop Out Voltage Maximum Reverse Logic Voltage Vac Vac Volts mA, rms Vdc Vdc mA W Vdc Vdc 120 24-140 400 2 5 4-6 20 100 1 -5 240 24-280 600 4 5 4-6 20 100 1 -5 120 24-140 400 2 24 18-32 8 2700 1 -5 240 24-280 600 4 24 18-32 8 2700 1 -5 Type/Function Grayhill Part Number Dual, Fusible, Normally Open, ZVT Dual, Fusible, Normally Open, ZVT, Inductive Load Specifications Units Nominal Line Voltage Load Voltage Range Minimum Peak Blocking Voltage Maximum Off-State Leakage @ 60 Hz Nominal Logic Voltage Logic Voltage Range Max. Logic Supply Current @ Nominal Vcc Module ID Resistance to Logic Ground Minimum Drop Out Voltage Vac Vac Volts mA, rms Vdc Vdc mA W Vdc 4#;*+..X 0%T IJE 70L-OAC 70L-OACA 70L-OAC-L 70L-OACA-L 120 24-140 600 2 5 4.5-28 7/CH 2.15K 1 240 24-280 600 4 5 4.5-28 7/CH 2.15K 1 Available from your local Grayhill Distributor. For prices and discounts, contact a local Sales Office, an authorized local Distributor or Grayhill. +..)418' 8'07' # 4#0)'X ..+01+5 JNIFIgIMMK *10'U KNLgGIHgENHN #:U KNLgGIHgFLFN 999T)4#;*+..T%1/ I/O 7 I/O Modules OpenLine(R) Modules