RS401L/KBL005 THRU RS407L/KBL10
Single Phase 4.0 AMPS. Silicon Bridge Rectifiers
Voltage Range
50 to 1000 Volts
Current
4.0 Amperes
Features
Ideal for printed circuit board
Reliable low cost construction
High surge current capability
High temperature soldering guaranteed:
250°C / 10 seconds / 0.375” ( 9.5mm )
lead length at 5 lbs., ( 2.3 kg ) tension
Leads solderable per MIL-STD-202,
Method 208
KBL
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Rating at 25°C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
Type Number RS
401L RS
402L RS
403L RS
404L RS
405L RS
406L RS
407L Units
Maximum Recurrent Peak Reverse Voltage 50 100 200 400 600 800 1000 V
Maximum RMS Voltage 35 70 140 280 420 560 700 V
Maximum DC Blocking Voltage 50 100 200 400 600 800 1000 V
Maximum Average Forward Rectified Current
@T A = 50°C 4.0 A
Peak Forward Surge Current, 8.3 ms Single
Half Sine-wave Superimposed on Rated Load
200
A
Maximum Instantaneous Forward
Voltage@ 3.0A Peak 1.0 V
Maximum Reverse Current
at Rated DC Blocking Voltage and 150°TA
Maximum DC Reverse Current
at Rated DC Blocking Voltage 10
1.0
uA
mA
Operating Temperature Range TA -55 to +150 °C
.77(19.558)
.73(18.542) .265(6.73)
.235(5.97)
.825(16.383)
.605(15.367)
.07(TYP)
(1.778)
.750MIN
(19)
156X450
.210(5.33)
.190(4.83)
.052(1.32)
(5.08)
CHAM
.200
TYP.
.048(1.22)
KBL
005 KBL
01 KBL
02 KBL
04 KBL
06 KBL
08 KBL
10
NOTES: 1. Mounting conditions, 0.5" lead length maximum.
AMBIENT TEMPERATURE, C
0 10 100
NUMBER OF CYCLES AT 60Hz
FIG.1-MAXIMUM FORWARD SURGE CURRENT
0
50
75
100
125
PEAK FORWARD SURGE CURRENT
AMPERES
AVERAGE FORWARD OUTPUT CURRENT
AMPERES
FIG.2-DERATING CURVE
OUTPUT RECTIFIED CURRENT
0
2.0
4.0
6.0
50 100 150
o
25
INSTANTANEOUS FORWARD CURRENT
AMPERES
FIG.3-TYPICAL FORWARD CHARACTERISTICS
00.2 0.4 0.6 0.8 1.0 1.2 1.4
0.1
10
1.0
INSTANTANEOUS FORWARD VOLTAGE, VOLTS.
0.01
FIG.4- TYPICAL REVERSE CHARACTERISTICS
020 40 60 80 100 120 140
0.01
0.1
1.0
10
PERCENT OF RATED PEAK REVERSE VOLTAGE. (%)
INSTANTANEOUS REVERSE CURRENT
AMPERES
0