MPD-45 45W Dual Output Medical Type series Features : Universal AC input / Full range Low leakage current 0.3mA Protections: Short circuit / Overload / Over voltage Cooling by free air convection 100% full load burn-in test Fixed switching frequency at 45KHz 3 years warranty EN60601-1 IEC60601-1 SPECIFICATION MODEL OUTPUT MPD-45A CH1 CH2 CH1 DC VOLTAGE 5V 12V 5V 24V RATED CURRENT 3.2A 2A 3.2A 1.2A CURRENT RANGE 0.4 ~ 5A 0.2 ~ 2.5A 0.4 ~ 5A 0.2 ~ 1.8A RATED POWER 40W OUTPUT POWER (max.) 52W with 18CFM min. Forced air convection 60mVp-p 150mVp-p CH1:4.5 ~ 5.5V 4.0% 7.0% 4.0% 7.0% LINE REGULATION 1.0% 2.0% 1.0% 2.0% LOAD REGULATION 3.0% 4.0% 3.0% 4.0% 800ms, 20ms/230VAC HOLD UP TIME (Typ.) 50ms/230VAC VOLTAGE RANGE 90 ~ 264VAC FREQUENCY RANGE 47 ~ 440Hz EFFICIENCY(Typ.) 76% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) 1.2A/115VAC LEAKAGE CURRENT OVERLOAD PROTECTION OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE SAFETY & ISOLATION RESISTANCE EMC EMI CONDUCTION & RADIATION (Note 4) HARMONIC CURRENT EMS IMMUNITY MTBF DIMENSION PACKING NOTE 120mVp-p CH1:4.5 ~ 5.5V VOLTAGE TOLERANCE Note.3 SETUP, RISE TIME OTHERS CH2 44.8W RIPPLE & NOISE (max.) Note.2 60mVp-p VOLTAGE ADJ. RANGE INPUT MPD-45B OUTPUT NUMBER 800ms, 20ms/115VAC at full load 16ms/115VAC at full load 127 ~ 370VDC 78% 0.7A/230VAC COLD START 15A/115VAC <0.3mA / 264VAC 30A/230VAC 53 ~ 75W rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed 5.75 ~ 6.75V on CH1 Protection type : Hiccup mode, recovers automatically after fault condition is removed -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.04%/ (0 ~ 50 ) on +5V output 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL2601-1, TUV EN60601-1, IEC60601-1 approved I/P-O/P:4KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55011 (CISPR11) Class B Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN60601-1-2, medical level, criteria A 291.3Khrs min. MIL-HDBK-217F (25 127*76*28mm (L*W*H) 0.2Kg; 72pcs/17.4Kg/1.35CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Mounting holes M1 and M2 should be grounded for EMI purposes. File Name:MPD-45-SPEC 2010-10-18 http://store.iiic.cc/ MPD-45 45W Dual Output Medical Type Mechanical Specification series Unit:mm 127 115.8 5.6 5.6 FG M1 M2 76 64.8 CN2 FS1 1 2 3 4 5 6 AC FUSE T2A/250V 1 2 CN1 FS2 AC FUSE T2A/250V SVR1 43. 2 max. 28 8 DC Output Connector (CN2) : Molex 5273-06 or equivalent Pin No. Assignment 1 +V 2,3 +5V 4,5 COM 6 NC AC Input Connector (CN1) : Molex 5277-02 or equivalent Assignment AC/N AC/L Pin No. 1 2 Mating Housing Terminal Molex 5195 or equivalent Molex 5194 or equivalent Mating Housing Terminal Molex 5195 or equivalent Molex 5194 or equivalent Block Diagram fosc : 45KHz RECTIFIERS & FILTER EMI FILTER I/P POWER SWITCHING FG O.L.P. +V RECTIFIERS & FILTER +5V COM DETECTION CIRCUIT PWM CONTROL Derating Curve RECTIFIERS & FILTER O.V.P. Static Characteristics 100 100 90 80 80 70 LOAD(%) LOAD (%) 60 40 20 -10 0 10 20 30 40 50 60 (HORIZONTAL) 60 50 40 90 AMBIENT TEMPERATURE ( ) 100 110 135 155 230 264 INPUT VOLTAGE (V) 60Hz File Name:MPD-45-SPEC 2010-10-18 http://store.iiic.cc/