E5_N-H/E5_N-HT Advanced and Multi-Loop controllers Universal compact digital process controllers The E5_N-H series of process controllers take the proven concept of the general purpose E5_N series to a process level. Main features of the E5_N-H series are universal inputs, process outputs and options such as transfer output, remote setpoint and setvalue programmer. * * * * * Control mode: ON/OFF or 2-PID, Valve control on EN-H/AN-H Control output: relay, voltage (pulse), SSR, linear current and voltage Power supply: 100/240 VAC or 24 VDC/VAC Easy PC connection for parameter cloning, setting and tuning Clear and intuitive set-up and operation Ordering information Type Input Output Fixed option Alarms Order code On-panel Universal TC/Pt/mV mA/V Relay output - 3 software E5CN-HR2M-500 AC100-240 alarms E5CN-HQ2M-500 AC100-240 2 SUB E5CN-HC2M-500 AC100-240 outputs E5CN-HV2M-500 AC100-240 48x48 mm model (includes supply voltage indication) Voltage (pulse) Current output Linear voltage output Relay output Voltage (pulse) Current output SV programmer (8 programs of 32 segments) Linear voltage output Note: - E5CN-HTQ2MD-500 AC/DC24 E5CN-HTC2M-500 AC100-240 E5CN-HTC2MD-500 AC/DC24 E5CN-HTV2M-500 AC100-240 E5CN-HTV2MD-500 AC/DC24 Order code E53-CNBN2 Control output 2 Voltage (for driving SSR) E53-CNQBN2 Event inputs Heater burnout/SSR failure/ Heater overcurrent detection Event inputs Communications RS-232C Transfer output E53-CN01N2 Communications RS-232C E53-CNQ01N2 Communications RS-232C Heater burnout/SSR failure/ Heater overcurrent detection Communications RS-485 Communications RS-485 E53-CNHBN2 E53-CNBFN2 Control output 2 Voltage (for driving SSR) E53-CNH01N2 E53-CN03N2 Control output 2 Voltage (for driving SSR) E53-CNQO3N2 Communications RS-485 Heater burnout/SSR failure/ Heater overcurrent detection Communications RS-485 3-phase heater burnout/SSR failure/ E53-CNHH03N2 Heater overcurrent detection Control output 2 Voltage (for driving SSR) 490 Transfer output E5CN-HV2MD-500 AC/DC24 E5CN-HTR2MD-500 AC/DC24 E5CN-H option boards (One slot available in each instrument) Event inputs E5CN-HC2MD-500 AC/DC24 E5CN-HTQ2M-500 AC100-240 Accessories Event inputs E5CN-HQ2MD-500 AC/DC24 E5CN-HTR2M-500 AC100-240 Output and Alarm Relays: 3 A/250 VAC, electrical life: 100,000 operations Output voltage (pulse): 12 V, 21 mA (ie. to drive solid state relays) Linear current: 0(4) to 20 mA Linear voltage output: 0 to 10 V Option E5CN-HR2MD-500 AC/DC24 E53-CNH03N2 E53-CNQFN2 Control output 2 Voltage (for driving SSR) Heater burnout/SSR failure/ Heater overcurrent detection E53-CNQHN2 Control output 2 Voltage (for driving SSR) 3-phase heater burnout/SSR failure/ E53-CNQHHN2 Heater overcurrent detection E5_N-H/E5_N-HT Advanced and Multi-Loop controllers Control method Auxiliary output Control output 1/2 Heater burnout Basic 2 alarm relays none fitted, 2 slots 48x96 mm model E5AN-HAA2HBM-500 AC100-240 E5EN-HAA2HBM-500 AC100-240 none fitted, 2 slots E5AN-HAA2HBMD-500 AC/DC24 E5EN-HAA2HBMD-500 AC/DC24 2 SSR output fitted E5AN-HSS2HBM-500 AC100-240 E5EN-HSS2HBM-500 AC100-240 2 SSR output fitted E5AN-HSS2HBMD-500 AC/DC24 E5EN-HSS2HBMD-500 AC/DC24 E5AN-HAA2HHBFM-500 AC100-240 E5EN-HAA2HHBFM-500 AC100-240 E5AN-HAA2HHBFMD-500 AC/DC24 E5EN-HAA2HHBFMD-500 AC/DC24 2 SSR output fitted E5AN-HSS2HHBFM-500 AC100-240 E5EN-HSS2HHBFM-500 AC100-240 2 SSR output fitted E5AN-HSS2HHBFMD-500 AC/DC24 E5EN-HSS2HHBFMD-500 AC/DC24 none fitted, 2 slots E5AN-HAA3BFM-500 AC100-240 E5EN-HAA3BFM-500 AC100-240 none fitted, 2 slots E5AN-HAA3BFMD-500 AC/DC24 E5EN-HAA3BFMD-500 AC/DC24 2 SSR output fitted E5AN-HSS3BFM-500 AC100-240 E5EN-HSS3BFM-500 AC100-240 2 SSR output fitted E5AN-HSS3BFMD-500 AC/DC24 E5EN-HSS3BFMD-500 AC/DC24 2 relay output fitted E5AN-HPRR2BM-500 AC100-240 E5EN-HPRR2BM-500 AC100-240 E5AN-HPRR2BMD-500 AC/DC24 E5EN-HPRR2BMD-500 AC/DC24 E5AN-HPRR2BFM-500 AC100-240 E5EN-HPRR2BFM-500 AC100-240 E5AN-HPRR2BFMD-500 AC/DC24 E5EN-HPRR2BFMD-500 AC/DC24 E5AN-HTAA2HBM-500 E5EN-HTAA2HBM-500 AC100-240 E5AN-HTAA2HBMD-500 E5EN-HTAA2HBMD-500 AC/DC24 E5AN-HTAA2HHBFM-500 E5EN-HTAA2HHBFM-500 E5AN-HTAA2HHBFMD-500 E5EN-HTAA2HHBFMD-500 E5AN-HTAA3BFM-500 E5EN-HTAA3BFM-500 E5AN-HTAA3BFMD-500 E5EN-HTAA3BFMD-500 E5AN-HTPRR2BM-500 E5EN-HTPRR2BM-500 E5AN-HTPRR2BMD-500 E5EN-HTPRR2BMD-500 E5AN-HTPRR2BFM-500 E5EN-HTPRR2BFM-500 E5AN-HTPRR2BFMD-500 E5EN-HTPRR2BFMD-500 1-phase 3-phase none fitted, 2 slots Valve controller 2 alarm relays 4 to 20 mA output 4 to 20 mA output SV programmer (8 programs of 32 segments 2 alarm relays none fitted, 2 slots 1-phase 3-phase 4 to 20 mA output 3 alarm relays SV programmer and 2 alarm relays valve controller Order code (includes supply voltage indication) 96x96 mm model none fitted, 2 slots 3 alarm relays Transfer output 2 relay output fitted 4 to 20 mA output Specifications E5CN-H/EN-H/AN-H E5AN-H/EN-H output option boards Supply voltage 100 to 240 VAC 50/60 Hz or 24 VAC, 50/60Hz; 24 VDC Sensor input Thermocouple: K, J, T, E, L, U, N, R, S, B, W or PL II (2 slots available in E5_N-HAA__-500 models: SS models have 2 fixed SSR output modules) Current input: 4 to 20 mA or 0 to 20 mA Voltage input: 1 to 5 V, 0 to 5 V or 0 to 10 V Control mode ON/OFF, 2-PID and valve (PRR) Accuracy Thermocouple: ( 0.1% of indicated value or 1C, whichever is greater) digit max. *1 Platinum resistance thermometer: ( 0.1% of indicated value or 0.5C, whichever is greater) 1 digit max. Analogue input: 0.1% FS 1 digit max. Auto-tuning yes, 40% and 100% MV output limit selection. When using Heat/Cool: automatic cool gain adjustment Self-tuning yes RS-232C/RS-422/RS-485 optional, CompowayF or Modbus selectable Event input Optional (Standard 2 event input in EN-H/AN-H) QLP port (USB connection PC) yes Ambient temperature -10 to 55C IP Rating front panel IP66 Sampling period 60 ms Option Order code Relay E53-RN Voltage (pulse) PNP 12 VDC E53-QN Voltage (pulse) NPN 12 VDC E53-Q3 Voltage (pulse) PNP 24 VDC E53-Q4 Linear 4 to 20 mA E53-C3N Linear 0 to 20 mA E53-C3DN Linear 0 to 10 V E53-V34N Linear 0 to 5 V E53-V35N E5AN-H/EN-H option boards (one slot available in each instrument) Option Order code RS-232C communications (CompoWay/F/Modbus) E53-EN01 RS-422 communications (CompoWay/F/Modbus) E53-EN02 RS-485 communications (CompoWay/F/Modbus) E53-EN03 event input E53-AKB 21 Platinum resistance thermometer: Pt100 or JPt100 Temperature controllers Note: - All E5EN-H/AN-H have 2 event inputs - All E5EN-H/AN-H have Remote Setpoint 4 to 20 mA input E5AN-H/EN-H series optional tools Option Order code USB PC based configuration cable E58-CIFQ1 PC based configuration and tuning software CX-Thermo EST2-2C-MV4 491