Page 2 HPR4XX REV F 4/99
ORDERING INFORMATION
HPR 4 XX /H
Device Family
HPR Indicates DC/DC converter
Model Number
Selected from Table of Electrical Characteristics
Screening Option
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified.
ELECTRICAL SPECIFICATIONS
Note: Other input to output voltages may be available. Please consult factory
COMMON SPECIFICATIONS
Specifications typical at TA = +25°C, nominal input voltage, rated output current unless otherwise specified.
NOMINAL RATED RATED INPUT CURRENT REFLECTED
INPUT OUTPUT OUTPUT RIPPLE
VOLTAGE VOLTAGE CURRENT NO LOAD RATED LOAD CURRENT EFFICIENCY
MODEL (VDC) (VDC) (mA) (mA) TYP MAX (mAp-p) (%)
HPR400 5 5 150 20 216 235 10 69
HPR401 5 12 62 20 212 235 5 70
HPR402 5 15 50 20 212 235 5 71
HPR403 5 ±5 ±75 20 218 245 5 68
HPR404 5 ±12 ±30 20 212 235 5 68
HPR405 5 ±15 ±25 20 220 220 5 75
HPR406 12 5 150 10 90 100 5 69
HPR407 12 12 62 10 81 90 5 77
HPR408 12 15 50 10 81 90 5 77
HPR409 12 ±5 ±75 10 88 98 5 71
HPR410 12 ±12 ±30 10 81 90 5 74
HPR411 12 ±15 ±25 10 81 90 5 77
HPR412 15 5 150 8 72 80 5 69
HPR413 15 12 62 8 72 80 5 69
HPR414 15 15 50 8 72 80 5 69
HPR415 15 ±5 ±75 8 72 80 5 69
HPR416 15 ±12 ±30 8 63 70 5 76
HPR417 15 ±15 ±25 8 63 66 5 79
HPR418 24 5 150 8 48 53 15 65
HPR419 24 12 62 8 48 53 15 65
HPR420 24 15 50 8 45 50 15 69
HPR421 24 ±5 ±75 8 45 50 15 69
HPR422 24 ±12 ±30 8 45 50 15 67
HPR423 24 ±15 ±25 8 45 50 15 69
PARAMETER CONDITIONS MIN TYP MAX UNITS
INPUT
Voltage Range 4.5 5 5.5 VDC
10.8 12 13.2 VDC
13.5 15 16.5 VDC
21.6 24 26.4 VDC
ISOLATION
Rated Voltage 1000 VDC
Test Voltage 60Hz, 60 Sec 3000 Vpk
Resistance 10 GW
Capacitance 15 pF
Leakage Current VISO= 240VAC, 60Hz 2 7 µArms
OUTPUT
Rated Power 750 mW
Voltage Setpoint Accuracy Rated Load, Nominal VIN ±5 %
Ripple & Noise BW = DC to 10MHz 45 mVp-p
BW =10Hz to 2MHz 30 mVrms
HPR403 BW = DC to 10MHz 90 mVp-p
Voltage 1 mA Load, VOUT = 5V 7 VDC
1 mA Load, VOUT= 12V 15 VDC
1 mA Load, VOUT = 15V 18 VDC
Temperature Coefficent .01 %/Deg C
REGULATION
Line Regulation High Line to Low Line 1 %/%Vin
Load Regulation (5V out only) Rated Load to 1mA Load 10 %
Load Regulation (All other Models) Rated Load to 1mA Load 3 %
GENERAL
Switching Frequency 170 kHz
Frequency Change Over Line and Load 24 %
Package Weight 2 g
MTTF per MIL-HDBK-217, Rev. E Circuit Stress Method
Ground Benign TA = +25°C 7.9 MHr
TEMPERATURE
Specification -25 +25 +85 °C
Operation -40 +100 °C
Storage -40 +110 °C
ABSOLUTE MAXIMUM RATINGS
Internal Power Dissipation..................................................................450mW
Short Circuit Duration....................................................................Momentary
Lead Temperature (soldering, 10 seconds max)................................+300°C