Jacket -
Conductor - Radiation Crosslinked
Tin Plated Copper Modified ETFE
Part Nominal Conductor Conductor
Number CSA Stranding Diameter Maximum Diameter Nominal
(mm²) No./ Diam. (mm) Resistance (mm) Weight
(mm) @ 20°C Lower Upper (kg/ km)
(ohms/ km) Spec Target Spec Mandrel Diam Weight
Min. Max. Limit Limit (mm) (±3%) (kg) (±3%)
FLHTC0311-0.25-* 0.25 19/0.13 0.55 0.63 83.3 0.96 1.00 1.03 2.95 9.5 0.23
FLHTC0311-0.35-* 0.35 19/0.15 0.74 0.76 52.2 1.12 1.16 1.19 4.22 13 0.36
FLHTC0311-0.50-* 0.50 19/0.19 0.86 0.88 40.1 1.24 1.27 1.31 5.59 13 0.50
FLHTC0311-0.75-* 0.75 19/0.23 1.05 1.08 24.7 1.43 1.47 1.51 7.95 13 0.50
FLHTC0311-1.00-* 1.00 19/0.25 1.17 1.26 20.0 1.58 1.62 1.66 9.9 13 0.50
FLHTC0311-1.50-* 1.50 19/0.32 1.35 1.58 13.7 1.82 1.87 1.92 15.7 19 0.68
FLHTC0311-2.00-* 2.00 19/0.36 1.66 1.79 9.7 2.05 2.10 2.16 18.7 25 0.91
FLHTC0311-2.50-* 2.50 19/0.41 1.85 2.01 8.2 2.24 2.31 2.38 24.6 38 1.36
PART NUMBER: The '*' in the part number shall be replaced by a standard colour code designator,
e.g. FLHTC0311-1.50-9 is 1.50mm², white insulation
INSULATION THICKNESS: Sizes 0.25 - 2.00 0.15 mm minimum; 0.165 mm (minimum average)
Size 2.50 0.165 mm minimum; 0.178 mm (minimum average)
ADDITIONAL REQUIREMENTS: Crosslink Verification: Time/ temperature - WCD3106 clause 3.3.4; voltage withstand - 2.5 kV;
mandrels and weights as shown
Insulation Tensile Strength: 37.7 N/mm² minimum
Insulation Elongation: 100% minimum
Deformation Test: To UL Factory Inspection Procedure, Subject 758 (Page 40), Style 3557 at 200°C
T2/ T1 minimum = 0.80
Thermal Stability: 7 days @ 232°C; Insulation elongation 60% minimum,
Insulation Tensile Strength 34.5 N/mm² minimum
Shrinkage: 3 mm maximum at each end at 200°C/ 1 hour
Insulation Resistance: 1524 Mohm.km minimum
Spark Test: 8.0 kV Impulse
®FLEXLITE is a registered trademark of Tyco Electonics Corporation
©2007 Tyco Electronics Corporation. All International Rights Reserved.
FLEXLITE®FLHTC0311
Issue 6
17th April 2007
Page 1 of 2
FINISHED WIRE
Crosslink
Verification Test
and the requirements of the issue in effect of WCD 3106. UL style 3557 and carries UL labels to this effect.
Specification Control Drawing
Page 2 is for internal use only
HIGH TEMPERATURE HOOKUP WIRE, TIN PLATED COPPER, RADIATION-CROSSLINKED,
MODIFIED ETFE INSULATED, 200°C, 600 VOLT
The complete requirements for procuring the wire described herein shall consist of this document, the Test Regime WSD 3106 (UK)
Tyco Electronics
UK Ltd
Faraday Road
Dorcan
SWINDON
SN3 5HH
Tel: (01793) 528171
Telex: 449409
This specification sheet takes precedence over documents referenced herein. As Tyco
Electronics UK Ltd. reserve the right to make changes in construction without notice please
contact Tyco Electronics UK Ltd to ensure that this document is the latest issue.
Registration
Number:
550926
London,
England
This drawing and the information set forth hereon are the property of Tyco Electronics UK Ltd, and are to
be held in trust and confidence. Publication, duplication, disclosure or use for any purpose not expressly