MODEL NUMBER
T
D2420Q
OU
T
P
U
T
SPE
C
I
F
I
C
A
T
ION
S
➀
Operating Voltage (47-63 Hz) [Vrms] 24-280
Load Current Range ➂[Arms] .15-20
Transient Overvoltage [Vpk] 600
Max. Surge Current, (16.6ms) [Apk] 250
Max. On-State Voltage Drop @ Rated Current [Vpk] 1.6
Thermal Resistance Junction to Case (RθJC) [ûC/W] 1.2
Maximum I2t for Fusing, (8.3 msec.) [A2sec] 260
Max. Off-State Leakage Current @ Rated Voltage [mArms] 10
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec] ➁200
Max. Turn-On Time ➃1/2 cycle
Max. Turn-Off Time 1/2 cycle
Power Factor (Min.) with Max. Load 0.5
IN
P
U
T
SPE
C
I
F
I
C
A
T
ION
S
➀
Control Voltage Range 4-15 Vdc
Max. Turn-On Voltage 4.0 Vdc
Min. Turn-Off Voltage 1.0 Vdc
Nominal Input Impedance 330 Ohms
Typical Input Current @ 5 Vdc 12 mA
•
Z
ero
V
oltage
and
R
andom
T
urn
-O
n
S
wit
c
hing
•
T
ria
c
O
utput
•I
ndu
s
try
S
tandard
P
a
c
kage
•
P
anel
M
ount
FastFax Document No. 166
QUAD
Rev. 041902
PAGE 1 OF 2
Four independent AC output relays
come in a single standard panel-mount
package. Utilizing an AC switch output
with internal snubber, relays provide
greater protection against false trigger-
ing. Model choices include zero-volt-
age or random turn-on (phase control-
lable) switching.
Manufactured in Crydom's ISO 9001
Certified facility for optimum product
performance and reliability.
Q
uad
R
elay
20Amp • 120/240 Vac • AC Output
G
E
N
E
R
A
L
NO
T
ES
➀All parameters at 25˚C and per section unless otherwise specified.
➁Off-State dv/dt test method per EIA/NARM standardRS-443, paragraph 13.11.1
➂Heat sinking required, max. 20A per section,
max
. 60A
per
pa
c
kage
.
➃Turn-on time for random turn-on versions is 0.1 msec.
©2002 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com
WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506