Tyco Electronics Identification
HX-SCE - High Performance Low Fire Hazard Identification Solution
Literature No. 1773110
Revised 06-05
Dimensions are shown for
reference purposes only.
Conversion Rate:
25.4mm = 1 inch
Dimensions are in inches and
millimetres unless otherwise
specified. Values in brackets
are metric equivalents.
Specifications subject to
change.
www.tycoelectronics.com
Technical Information
Print Method/Ribbon:
T312M-PRINTER with 1966-RIBBON or
T212M-PRINTER with T200-1966-RIBBON
Service Temperature: -30°C to +105°C (-22°F to +221°F).
Minimum Shrink Temperature: 135°C (275°F).
Colours: White or yellow.
Other colours available on request.
Flammability: Self-extinguishing -
(ASTM D2671 Procedure B).
Oxygen Index (BS6853: Pass 34% Min.) -
(BS EN ISO 4589-2 [1999]).
(AFNOR NF F 16-101 Class I2).
Dripping Classification ST2 - (DIN 5510-2)
Smoke: A0=0.017 Max. - (BS 6853 [1999]
Annex D [D.8.3]) Small scale test
Smoke Index Determination (IF)
Maximum 20, Smoke Class F1 -
(AFNOR NF F 16-101-1988 Smoke Index)
Toxicity: R < 1 - (BS 6853 [1999] Annex B –
AFNOR NF X 70-100 Determination of
weighted summation of toxic fume, mass
based method)
LUL Toxic Fume: No Halogens, No P, S
or N sources above trace level -
(LUL E1042: A6 [2002]).
(London Underground Standard
2-01001-002, section 5.2.3. Chemical
composition / toxicity)
Toxicity (continued): Toxicity Index = 0.34 -
(CEI 20-37-7 09-1997 Determination of
toxicity index of gases from combustion
of organic material)
Dielectric Strength: 15kV/mm minimum.
Water Absorbsion: 1% maximum after 24 hours at 23°C
(73°F).
Copper Mirror Corrosion: 8% maximum after 16 hours at 150°C
(302°F).
Longitudinal Change: +5% to -10%.
Tensile Strength: 7MPa minimum.
Ultimate Elongation: 80% minimum.
Secant Modulas: 200MPa maximum at 2% elongation.
UV Resistance: Tensile strength > 90% & Ultimate
(base polymer) elongation > 40% of original value after
1000 hours (ASTM G53: UVA [100%
dry cycle]; UVB [8 hours dry/4 hours
wet cycle]).
Print Permanence: ADHERENCE - Meets the requirements
of SAE AS81531 4.6.2 (50 rubs).
FLUID RESISTANCE - Meets the
requirements of MIL-STD-202F method
215J.
Industry Standards
Standard Title Application
BS6853 Code of practice for fire precautions in the design Interior minor use materials of mass 100g to 500g.
and construction of passenger carrying trains Vehicle category la
1London Underground Limited Fire Safety Performance of Materials Limited, Dispersed usage (abbreviation RS/EQ/I)
Standard 2-01001-002
NF F 16-101 Railway Rolling Stock Fire behavior choice of materials Rolling Stock Classification A1
DIN 5510-2 Preventive fire protection in railway vehicles - Part 2: Fire Dripping Classification ST2
behavior and fire side effects of materials and parts;
Classification, Requirements and test methods
2EN50343 Railway Applications - Rolling Stock - Tests on marking when using heat-shrinkable sleeves
Rules for installation of cabling
1This replaces LUL Engineering Standard E 1042
2Not including resistance to liquid fuel - not recommended for use in areas where the sleeves may be subject to extended contact from diesel fuel -
Tyco Electronics D-SCE product range is designed for use in these areas