Document Number: 93138 For technical questions, contact: ind-modules@vishay.com www.vishay.com
Revision: 26-Sep-08 1
Fast Recovery Diodes
(Stud Version), 6/12/16 A
1N3879(R), 1N3889(R), 6/12/16FL(R) Series
Vishay High Power Products
FEATURES
Short reverse recovery time
Low stored charge
Wide current range
Excellent surge capabilities
Standard JEDEC types
Stud cathode and stud anode versions
Fully characterized reverse recovery conditions
RoHS compliant
TYPICAL APPLICATIONS
DC power supplies
•Inverters
Converters
Choppers
Ultrasonic systems
Freewheeling diodes
Note
(1) JEDEC registered values
PRODUCT SUMMARY
IF(AV) 6/12/16 A
DO-203AA (DO-4)
RoHS
COMPLIANT
MAJOR RATINGS AND CHARACTERISTICS
SYMBOL CHARACTERISTICS 1N3879. TO
1N3883.
1N3889. TO
1N3893. 6FL.. 12FL.. 16FL.. UNITS
IF(AV) TC = 100 °C 6 (1) 12 (1) 61216A
IF(RMS) 9.5199.519 25 A
IFSM
50 Hz 72 145 110 145 180
A
60 Hz 75 (1) 150 (1) 115 150 190
I2t
50 Hz 26 103 60 103 160
A2s
60 Hz 23 94 55 94 150
I2t 363 856 1452 1452 2290 I2s
VRRM Range 50 to 400 (1) 50 to 1000 V
trr See Recovery Characteristics table ns
TJRange - 65 to 150 °C
www.vishay.com For technical questions, contact: ind-modules@vishay.com Document Number: 93138
2Revision: 26-Sep-08
1N3879(R), 1N3889(R), 6/12/16FL(R) Series
Vishay High Power Products Fast Recovery Diodes
(Stud Version), 6/12/16 A
ELECTRICAL SPECIFICATIONS
Note
(1) JEDEC registered values
Note
(1) JEDEC registered values
VOLTAGE RATINGS
TYPE
NUMBER
VOLTAGE
CODE
VRRM, MAXIMUM
REPETITIVE PEAK AND
OFF-STATE VOLTAGE
V
VRSM, MAXIMUM
NON-REPETITIVE
PEAK VOLTAGE
V
IRRM MAXIMUM
AT TJ = 25 °C
µA
IRRM MAXIMUM
AT TJ = 100 °C
mA
IRRM MAXIMUM
AT TJ = 150 °C
mA
1N3879.
-
50 75
15 (1) 1.0 (1) 3.0 (1)
1N3880. 100 150
1N3881. 200 250
1N3882. 300 350
1N3883. 400 450
1N3889.
-
50 75
25 (1) 3.0 (1) 5.0 (1)
1N3890. 100 150
1N3891. 200 250
1N3892. 300 350
1N3893. 400 450
6FL..
12FL..
16FL..
550 75
50 - 6.0
10 100 150
20 200 275
40 400 500
60 600 725
80 800 950
100 1000 1250
FORWARD CONDUCTION
PARAMETER SYMBOL TEST CONDITIONS 1N3879.
1N3883. 6FL..
1N3889.
1N3893.
12FL..
16FL.. UNITS
Maximum average forward current
at case temperature IF(AV)
180° conduction, half sine wave
DC
6 (1) 612 (1) 16 A
100 100 100 100 °C
Maximum RMS current IF(RMS) 9.5 9.5 19 25
A
Maximum peak, one-cycle
non-repetitive forward current IFSM
t = 10 ms No voltage
reapplied
Sinusoidal
half wave,
initial
TJ = 150 °C
85 130 170 215
t = 8.3 ms 90 135 180 225
t = 10 ms 100 % VRRM
reapplied
72 110 145 180
t = 8.3 ms 75 (1) 115 150 (1) 190
Maximum I2t for fusing I2t
t = 10 ms No voltage
reapplied
36 86 145 230
A2s
t = 8.3 ms 33 78 130 210
t = 10 ms 100 % VRRM
reapplied
26 60 103 160
t = 8.3 ms 23 55 94 150
Maximum I2t for fusing I2t t = 0.1 to 10 ms, no voltage reapplied 363 856 1452 2290 A2s
Maximum forward voltage drop VFM
TJ = 25 °C; IF = Rated IF(AV) (DC) 1.4 (1) 1.4 1.4 (1) 1.4 V
TC = 100 °C; IFM = π x rated IF(AV) 1.5 (1) 1.5 1.5 (1) 1.5 V
Document Number: 93138 For technical questions, contact: ind-modules@vishay.com www.vishay.com
Revision: 26-Sep-08 3
1N3879(R), 1N3889(R), 6/12/16FL(R) Series
Fast Recovery Diodes
(Stud Version), 6/12/16 A Vishay High Power Products
Note
(1) JEDEC registered values
RECOVERY CHARACTERISTICS
PARAMETER SYMBOL TEST CONDITIONS 1N3879.
1N3883.
1N3889.
1N3893.
6FL..
12FL..
16FL.. UNITS
S02 S05
Maximum reverse
recovery time trr
TJ = 25 °C, IF = 1 A to VR = 30 V,
dIF/dt = 100 A/µs 150 150 - -
ns
TJ = 25 °C, dIF/dt = 25 A/µs,
IFM = π x rated IF(AV)
300 (1) 300 (1) 200 500
Maximum peak
recovery current IRM(REC) IFM = π x rated IF(AV) 4 (1) 5 (1) --
Maximum reverse
recovery charge Qrr
TJ = 25 °C, IF = 1 A to VR = 30 V,
dIF/dt = 100 A/µs 400 350 - -
nC
TJ = 25 °C, dIF/dt = 25 A/µs,
IFM = π x rated IF(AV)
400 400 - -
IFM trr
dir
dt
IRM(REC)
Qrr
t
THERMAL AND MECHANICAL SPECIFICATIONS
PARAMETER SYMBOL TEST CONDITIONS
1N3879.
1N3883.
6FL..
1N3889.
1N3893.
12FL..
16FL.. UNITS
Maximum junction operating
temperature range TJ- 65 to 150
°C
Maximum storage temperature range TStg - 65 to 175
Maximum thermal resistance,
junction to case RthJC DC operation 2.5 2.0 1.6
°C/W
Maximum thermal resistance,
case to heatsink RthCS
Mounting surface, smooth,
flat and greased 0.5
Allowable mounting torque
Not lubricated threads 1.5 + 0 - 10 %
(13) N · m
(lbf · in)
Lubricated threads 1.2 + 0 - 10 %
(10)
Approximate weight
7g
0.25 oz.
Case style JEDEC DO-203AA (DO-4)
www.vishay.com For technical questions, contact: ind-modules@vishay.com Document Number: 93138
4Revision: 26-Sep-08
1N3879(R), 1N3889(R), 6/12/16FL(R) Series
Vishay High Power Products Fast Recovery Diodes
(Stud Version), 6/12/16 A
Note
The table above shows the increment of thermal resistance RthJC when devices operate at different conduction angles than DC
Fig. 1 - Average Forward Current vs.
Maximum Allowable Case Temperature,
1N3879 and 6FL Series
Fig. 2 - Average Forward Current vs.
Maximum Allowable Case Temperature,
1N3889 and 12FL Series
Fig. 3 - Average Forward Current vs.
Maximum Allowable Case Temperature, 16FL Series
Fig. 4 - Reverse Recovery Time Test Waveform
ΔRthJC CONDUCTION
CONDUCTION ANGLE
1N3879.
1N3883.
6FL..
1N3889.
1N3893.
12FL..
16FL..
1N3879.
1N3883.
6FL..
1N3889.
1N3893.
12FL..
16FL..
TEST CONDITIONS UNITS
SINUSOIDAL CONDUCTION RECTANGULAR CONDUCTION
180° 0.58 0.46 0.37 0.33 0.26 0.21
TJ = 150 °C K/W
120° 0.60 0.48 0.39 0.58 0.46 0.37
60° 1.28 1.02 0.82 1.28 1.02 0.82
30° 2.20 1.76 1.41 2.20 1.76 1.41
Document Number: 93138 For technical questions, contact: ind-modules@vishay.com www.vishay.com
Revision: 26-Sep-08 5
1N3879(R), 1N3889(R), 6/12/16FL(R) Series
Fast Recovery Diodes
(Stud Version), 6/12/16 A Vishay High Power Products
Fig. 5 - Current Rating Nomogram (Sinusoidal Waveforms), 1N3879 and 6FL Series
Fig. 6 - Current Rating Nomogram (Rectangular Waveforms), 1N3879 and 6FL Series
Fig. 7 - Current Rating Nomogram (Sinusoidal Waveforms), 1N3889 and 12FL Series
www.vishay.com For technical questions, contact: ind-modules@vishay.com Document Number: 93138
6Revision: 26-Sep-08
1N3879(R), 1N3889(R), 6/12/16FL(R) Series
Vishay High Power Products Fast Recovery Diodes
(Stud Version), 6/12/16 A
Fig. 8 - Current Rating Nomogram (Rectangular Waveforms), 1N3889 and 12FL Series
Fig. 9 - Current Rating Nomogram (Sinusoidal Waveforms), 16FL Series
Fig. 10 - Current Rating Nomogram (Rectangular Waveforms), 16FL Series
Document Number: 93138 For technical questions, contact: ind-modules@vishay.com www.vishay.com
Revision: 26-Sep-08 7
1N3879(R), 1N3889(R), 6/12/16FL(R) Series
Fast Recovery Diodes
(Stud Version), 6/12/16 A Vishay High Power Products
Fig. 11 - Maximum Forward Voltage vs. Forward Current,
1N3879 and 6FL Series
Fig. 12 - Maximum High Level Forward Power Loss vs.
Average Forward Current,
1N3879 and 6FL Series
Fig. 13 - Maximum Forward Voltage vs. Forward Current,
1N3889 and 12FL Series
Fig. 14 - Maximum High Level Forward Power Loss vs.
Average Forward Current,
1N3889 and 12FL Series
Fig. 15 - Maximum Forward Voltage vs. Forward Current,
16FL Series
Fig. 16 - Maximum High Level Forward Power Loss vs.
Average Forward Current,
16FL Series
www.vishay.com For technical questions, contact: ind-modules@vishay.com Document Number: 93138
8Revision: 26-Sep-08
1N3879(R), 1N3889(R), 6/12/16FL(R) Series
Vishay High Power Products Fast Recovery Diodes
(Stud Version), 6/12/16 A
Fig. 17a - Typical Reverse Recovery Time vs.
Rate of Fall of Forward Current, All Series ...S02
Fig. 17b - Typical Recovered Charge vs.
Rate of Fall of Forward Current, All Series ...S02
Fig. 18a - Typical Reverse Recovery Time vs.
Rate of Fall of Forward Current, All Series ...S05
Fig. 18b - Typical Recovered Charge vs.
Rate of Fall of Forward Current, All Series ...S05
Fig. 19a - Typical Reverse Recovery Time vs.
Rate of Fall of Forward Current, All Series ...S10
Fig. 19b - Typical Recovered Charge vs.
Rate of Fall of Forward Current, All Series ...S10
Document Number: 93138 For technical questions, contact: ind-modules@vishay.com www.vishay.com
Revision: 26-Sep-08 9
1N3879(R), 1N3889(R), 6/12/16FL(R) Series
Fast Recovery Diodes
(Stud Version), 6/12/16 A Vishay High Power Products
Fig. 20 - Maximum Non-Repetitive Surge Current vs.
Number of Current Pulses, 1N3879 Series
Fig. 21 - Maximum Non-Repetitive Surge Current vs.
Number of Current Pulses, 6FL Series
Fig. 22 - Maximum Non-Repetitive Surge Current vs.
Number of Current Pulses, 1N3889 and 12FL Series
Fig. 23 - Maximum Non-Repetitive Surge Current vs.
Number of Current Pulses, 16FL Series
Fig. 24 - Maximum Transient Thermal Impedance,
Junction to Case vs. Pulse Duration, All Series
www.vishay.com For technical questions, contact: ind-modules@vishay.com Document Number: 93138
10 Revision: 26-Sep-08
1N3879(R), 1N3889(R), 6/12/16FL(R) Series
Vishay High Power Products Fast Recovery Diodes
(Stud Version), 6/12/16 A
ORDERING INFORMATION TABLE
3- Omit = Standard recovery diode
L = Only for fast diode
6- Outlines:
Omit = Stud base UNF thread
M = Stud base metric thread
4- Omit = Stud forward polarity
R = Stud reverse polarity
1- Current code I(AVG) = Exact current rating
2- F = Diode
5- Voltage code x 10 = VRRM (see Voltage Ratings table)
7-t
rr code only for fast diode (see Recovery Characteristics table)
Device code
51324
67
16 F L R 60 M S02
LINKS TO RELATED DOCUMENTS
Dimensions http://www.vishay.com/doc?95311
Document Number: 91000 www.vishay.com
Revision: 18-Jul-08 1
Disclaimer
Legal Disclaimer Notice
Vishay
All product specifications and data are subject to change without notice.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf
(collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein
or in any other disclosure relating to any product.
Vishay disclaims any and all liability arising out of the use or application of any product described herein or of any
information provided herein to the maximum extent permitted by law. The product specifications do not expand or
otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed
therein, which apply to these products.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this
document or by any conduct of Vishay.
The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications unless
otherwise expressly indicated. Customers using or selling Vishay products not expressly indicated for use in such
applications do so entirely at their own risk and agree to fully indemnify Vishay for any damages arising or resulting
from such use or sale. Please contact authorized Vishay personnel to obtain written terms and conditions regarding
products designed for such applications.
Product names and markings noted herein may be trademarks of their respective owners.