Page 2 of 2
SCD Number
44A0811
WIRE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 150°C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
ACCELERATED AGING: 300 ± 2°C for 6 hours
Identification legibility, 225 ± 2°C for 6 hours
BLOCKING: 150 ± 2°C for 24 hours
COLOR: White preferred
FLAMMABILITY: 30 seconds (maximum); 3 inches (maximum); no flaming of facial tissue
HUMIDITY RESISTANCE: Insulation Resistance, 5000 megohms for 1000 ft (minimum)
IDENTIFICATION, STRIPING, OR BAND DURABILITY:
125 cycles (250 strokes) (minimum), 500 g weight
IMMERSION: Diameter increase 5% (maximum); no cracking, no dielectric breakdown
INSULATION ELONGATION AND TENSILE STRENGTH:
Primary Insulation,
Elongation, 150% (minimum)
Tensile Strength, 2500 lbf/in² (minimum), AWG 26-12
2000 lbf/in² (minimum), AWG 10 & larger
INSULATION FLAWS:
Primary Insulation,
SparkTest, 3.0 kV (rms) at 60 Hz
4.2 kV (rms) at 3 kHz
Impulse DielectricTest, 6.0 kV (peak)
Finished Wire,
SparkTest, 5.7 kV (rms) at 3 kHz
Impulse DielectricTest, 8.0 kV (peak)
INSULATION RESISTANCE: 5000 megohms for 1000 ft (minimum)
LIFE CYCLE: 200 ± 2°C for 168 hours
LOW TEMPERATURE COLD BEND: -65 ± 2°C for 4 hours
SHRINKAGE: 300 ± 2°C, 0.125 in. (maximum) in 12 inches, AWG 26-12
0.250 in. (maximum) in 12 inches, AWG 10 & larger
SMOKE: 200 ± 2°C, no visible smoke.
SOLDERABILITY: 95% minimum coverage.
Per MIL-STD-202, Method 208, except without steam aging, Type RMA Flux (for
10 AWG & smaller only)
SURFACE RESISTANCE: 500 megohms-in. (minimum), both readings
THERMAL SHOCK RESISTANCE: 150 ± 2°C, 0.060 in. (maximum)
VOLTAGE WITHSTAND (Post Environmental): 2500 volts (rms), 60 Hz, 5 minutes
WICKING: 2.25 in. (maximum)
PART NUMBER:
The "*" in the part numbers on page 1 shall be replaced by color code designators.
1/ Example: AWG 18, white: 44A0811-18-9
AWG 14, white with a black stripe: 44A0811-14-90
1/ See Footer section on page 1.
Revision
SPECIFICATION CONTROL DRAWING P