Date Revision
TITLE
This specification sheet forms a part of the latest issue of Raychem Specification 44.
CONDUCTOR - TIN-COATED COPPER JACKET - RADIATION-CROSSLINKED,
MODIFIED PVDF,
Thickness:
AWG 26 - 4
.005 ± .001 in.
AWG 2 - 000
.010 ± .002 in.
P
WIRE, RADIATION-CROSSLINKED, POLYALKENE-INSULATED,
MEDIUM WEIGHT, 600 VOLT
PART NUMBER
1/
WIRE
SIZE
(AWG)
CONDUCTOR
STRANDING
(number x AWG)
DIAMETER OF
STRANDED
CONDUCTOR
(in.)
MINIMUM MAXIMUM
MAXIMUM
RESISTANCE AT
20°C
(ohms/1000ft.)
TABLE I. CONSTRUCTION DETAILS
MAXIMUM
WEIGHT
(lbs/1000 ft.)
DIAMETER
(in.)
.018
.023
.029
.037
.046
.052
.065
.084
.106
.158
.198
.250
.320
.405
.450
.515
.021
.026
.033
.041
.051
.058
.073
.090
.114
.173
.217
.274
.340
.425
.475
.540
1.9
2.6
3.8
5.4
8.0
9.9
14.9
21.9
35.0
62.8
99.3
153.
247.
377.
498.
588.
41.3
26.2
16.2
9.88
6.23
4.81
3.06
2.02
1.26
.701
.445
.280
.183
.116
.091
.071
.048 ± .002
.054 ± .002
.062 ± .003
.070 ± .003
.080 ± .003
.089 ± .004
.108 ± .004
.126 ± .004
.155 ± .005
.214 ± .006
.264 ± .007
.320 ± .008
.400 ± .012
.490 ± .016
.562 ± .016
.634 ± .020
19 x 38
19 x 36
19 x 34
19 x 32
19 x 30
19 x 29
19 x 27
37 x 28
37 x 26
133 x 29
133 x 27
133 x 25
665 x 30
1045 x 30
1330 x 30
1665 x 30
44A0811-26-*
44A0811-24-*
44A0811-22-*
44A0811-20-*
44A0811-18-*
44A0811-16-*
44A0811-14-*
44A0811-12-*
44A0811-10-*
44A0811- 8-*
44A0811- 6-*
44A0811- 4-*
44A0811- 2-*
44A0811- 0-*
44A0811-00-*
44A0811-000-*
FINISHED WIRE
26
24
22
20
18
16
14
12
10
8
6
4
2
0
00
000
PART NUMBER
1/
TABLE II. PERFORMANCE DETAILS
BEND TESTING
MANDREL DIAMETER
(inch) (± 3%)
COLD
BEND WRAP
IMMERSION,
LIFE CYCLE AND
ACCELERATED AGING
IMMERSION,
LIFE CYCLE AND
ACCELERATED AGING
COLD
BEND
44A0811-26-*
44A0811-24-*
44A0811-22-*
44A0811-20-*
44A0811-18-*
44A0811-16-*
44A0811-14-*
44A0811-12-*
44A0811-10-*
44A0811- 8-*
44A0811- 6-*
44A0811- 4-*
44A0811 - 2-*
44A0811- 0-*
44A0811-00-*
44A0811-000-*
.500
.500
.750
.750
1.00
1.00
1.50
2.00
3.00
3.00
4.00
5.00
6.00
8.00
10.0.
18.0
1.00
1.00
1.00
1.00
1.50
1.50
2.00
2.00
3.00
4.00
5.00
6.00
8.00
10.0
12.0
18.0
.250
.250
.250
.250
.375
.375
.500
.500
.750
.750
1.00
1.25
3.00
4.00
4.50
6.00
0.50
0.50
1.50
2.00
2.00
2.00
2.00
2.00
2.00
3.00
3.00
3.00
4.00
4.00
5.00
6.00
3.00
3.00
3.00
4.00
4.00
5.00
5.00
5.00
5.00
6.00
10.0
10.0
15.0
15.0
20.0
20.0
WEIGHT
(lb) (± 3%)
44A0811
05-31-06
SPECIFICATION CONTROL DRAWING
PRIMARY INSULATION - RADIATION-CROSSLINKED,
EXTRUDED POLYALKENE
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
Page 1 of 2
RR
RR
R
501 Oakside Avenue
Redwood City, California 94063-3800
1-800-227-8816 Fax: 1-650-361-6297
Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
Wire & Cable
DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE
ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
© 2006 Tyco Electronics Corporation. All rights reserved.
SCD Number
Page 2 of 2
SCD Number
44A0811
WIRE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 150°C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
ACCELERATED AGING: 300 ± 2°C for 6 hours
Identification legibility, 225 ± 2°C for 6 hours
BLOCKING: 150 ± 2°C for 24 hours
COLOR: White preferred
FLAMMABILITY: 30 seconds (maximum); 3 inches (maximum); no flaming of facial tissue
HUMIDITY RESISTANCE: Insulation Resistance, 5000 megohms for 1000 ft (minimum)
IDENTIFICATION, STRIPING, OR BAND DURABILITY:
125 cycles (250 strokes) (minimum), 500 g weight
IMMERSION: Diameter increase 5% (maximum); no cracking, no dielectric breakdown
INSULATION ELONGATION AND TENSILE STRENGTH:
Primary Insulation,
Elongation, 150% (minimum)
Tensile Strength, 2500 lbf/in² (minimum), AWG 26-12
2000 lbf/in² (minimum), AWG 10 & larger
INSULATION FLAWS:
Primary Insulation,
SparkTest, 3.0 kV (rms) at 60 Hz
4.2 kV (rms) at 3 kHz
Impulse DielectricTest, 6.0 kV (peak)
Finished Wire,
SparkTest, 5.7 kV (rms) at 3 kHz
Impulse DielectricTest, 8.0 kV (peak)
INSULATION RESISTANCE: 5000 megohms for 1000 ft (minimum)
LIFE CYCLE: 200 ± 2°C for 168 hours
LOW TEMPERATURE COLD BEND: -65 ± 2°C for 4 hours
SHRINKAGE: 300 ± 2°C, 0.125 in. (maximum) in 12 inches, AWG 26-12
0.250 in. (maximum) in 12 inches, AWG 10 & larger
SMOKE: 200 ± 2°C, no visible smoke.
SOLDERABILITY: 95% minimum coverage.
Per MIL-STD-202, Method 208, except without steam aging, Type RMA Flux (for
10 AWG & smaller only)
SURFACE RESISTANCE: 500 megohms-in. (minimum), both readings
THERMAL SHOCK RESISTANCE: 150 ± 2°C, 0.060 in. (maximum)
VOLTAGE WITHSTAND (Post Environmental): 2500 volts (rms), 60 Hz, 5 minutes
WICKING: 2.25 in. (maximum)
PART NUMBER:
The "*" in the part numbers on page 1 shall be replaced by color code designators.
1/ Example: AWG 18, white: 44A0811-18-9
AWG 14, white with a black stripe: 44A0811-14-90
1/ See Footer section on page 1.
Revision
SPECIFICATION CONTROL DRAWING P