SCD Number SPECIFICATION CONTROL DRAWING WIRE, RADIATION-CROSSLINKED, POLYALKENE-INSULATED, MEDIUM WEIGHT, 600 VOLT TITLE Date 05-31-06 44A0811 Revision P This specification sheet forms a part of the latest issue of Raychem Specification 44. CONDUCTOR - TIN-COATED COPPER PRIMARY INSULATION - RADIATION-CROSSLINKED, EXTRUDED POLYALKENE JACKET - RADIATION-CROSSLINKED, MODIFIED PVDF, Thickness: AWG 26 - 4 .005 .001 in. AWG 2 - 000 .010 .002 in. TABLE I. CONSTRUCTION DETAILS PART NUMBER 1/ 44A0811-26-* 44A0811-24-* 44A0811-22-* 44A0811-20-* 44A0811-18-* 44A0811-16-* 44A0811-14-* 44A0811-12-* 44A0811-10-* 44A0811- 8-* 44A0811- 6-* 44A0811- 4-* 44A0811- 2-* 44A0811- 0-* 44A0811-00-* 44A0811-000-* CONDUCTOR WIRE SIZE STRANDING (AWG) (number x AWG) 26 24 22 20 18 16 14 12 10 8 6 4 2 0 00 000 19 19 19 19 19 19 19 37 37 133 133 133 665 1045 1330 1665 x x x x x x x x x x x x x x x x 38 36 34 32 30 29 27 28 26 29 27 25 30 30 30 30 DIAMETER OF STRANDED CONDUCTOR (in.) MINIMUM MAXIMUM .021 .018 .026 .023 .033 .029 .041 .037 .051 .046 .058 .052 .073 .065 .090 .084 .114 .106 .173 .158 .198 .217 .274 .250 .340 .320 .425 .405 .450 .475 .540 .515 FINISHED WIRE MAXIMUM RESISTANCE AT 20C (ohms/1000ft.) 41.3 26.2 16.2 9.88 6.23 4.81 3.06 2.02 1.26 .701 .445 .280 .183 .116 .091 .071 DIAMETER (in.) .048 .054 .062 .070 .080 .089 .108 .126 .155 .214 .264 .320 .400 .490 .562 .634 .002 .002 .003 .003 .003 .004 .004 .004 .005 .006 .007 .008 .012 .016 .016 .020 MAXIMUM WEIGHT (lbs/1000 ft.) 1.9 2.6 3.8 5.4 8.0 9.9 14.9 21.9 35.0 62.8 99.3 153. 247. 377. 498. 588. TABLE II. PERFORMANCE DETAILS BEND TESTING PART NUMBER 1/ 44A0811-26-* 44A0811-24-* 44A0811-22-* 44A0811-20-* 44A0811-18-* 44A0811-16-* 44A0811-14-* 44A0811-12-* 44A0811-10-* 44A0811- 8-* 44A0811- 6-* 44A0811- 4-* 44A0811 - 2-* 44A0811- 0-* 44A0811-00-* 44A0811-000-* MANDREL DIAMETER (inch) ( 3%) IMMERSION, COLD LIFE CYCLE AND BEND ACCELERATED AGING .500 .500 .750 .750 1.00 1.00 1.50 2.00 3.00 3.00 4.00 5.00 6.00 8.00 10.0. 18.0 1.00 1.00 1.00 1.00 1.50 1.50 2.00 2.00 3.00 4.00 5.00 6.00 8.00 10.0 12.0 18.0 WRAP .250 .250 .250 .250 .375 .375 .500 .500 .750 .750 1.00 1.25 3.00 4.00 4.50 6.00 WEIGHT (lb) ( 3%) IMMERSION, LIFE CYCLE AND ACCELERATED AGING 0.50 0.50 1.50 2.00 2.00 2.00 2.00 2.00 2.00 3.00 3.00 3.00 4.00 4.00 5.00 6.00 COLD BEND 3.00 3.00 3.00 4.00 4.00 5.00 5.00 5.00 5.00 6.00 10.0 10.0 15.0 15.0 20.0 20.0 Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice. Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer. 1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. OTHER CODES AND SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER. DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL. Page 1 of 2 THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN. REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID. R Wire & Cable 501 Oakside Avenue Redwood City, California 94063-3800 1-800-227-8816 Fax: 1-650-361-6297 (c) 2006 Tyco Electronics Corporation. All rights reserved. SPECIFICATION CONTROL DRAWING Revision Page 2 of 2 P SCD Number 44A0811 WIRE RATINGS AND ADDITIONAL REQUIREMENTS TEMPERATURE RATING: 150C Maximum continuous conductor temperature VOLTAGE RATING: 600 volts (rms) at sea level ACCELERATED AGING: 300 2C for 6 hours Identification legibility, 225 2C for 6 hours BLOCKING: 150 2C for 24 hours COLOR: White preferred FLAMMABILITY: 30 seconds (maximum); 3 inches (maximum); no flaming of facial tissue HUMIDITY RESISTANCE: Insulation Resistance, 5000 megohms for 1000 ft (minimum) IDENTIFICATION, STRIPING, OR BAND DURABILITY: 125 cycles (250 strokes) (minimum), 500 g weight IMMERSION: Diameter increase 5% (maximum); no cracking, no dielectric breakdown INSULATION ELONGATION AND TENSILE STRENGTH: Primary Insulation, Elongation, 150% (minimum) Tensile Strength, 2500 lbf/in (minimum), AWG 26-12 2000 lbf/in (minimum), AWG 10 & larger INSULATION FLAWS: Primary Insulation, SparkTest, 3.0 kV (rms) at 60 Hz 4.2 kV (rms) at 3 kHz Impulse DielectricTest, 6.0 kV (peak) Finished Wire, SparkTest, 5.7 kV (rms) at 3 kHz Impulse DielectricTest, 8.0 kV (peak) INSULATION RESISTANCE: 5000 megohms for 1000 ft (minimum) LIFE CYCLE: 200 2C for 168 hours LOW TEMPERATURE COLD BEND: -65 2C for 4 hours SHRINKAGE: 300 2C, 0.125 in. (maximum) in 12 inches, AWG 26-12 0.250 in. (maximum) in 12 inches, AWG 10 & larger SMOKE: 200 2C, no visible smoke. SOLDERABILITY: 95% minimum coverage. Per MIL-STD-202, Method 208, except without steam aging, Type RMA Flux (for 10 AWG & smaller only) SURFACE RESISTANCE: 500 megohms-in. (minimum), both readings THERMAL SHOCK RESISTANCE: 150 2C, 0.060 in. (maximum) VOLTAGE WITHSTAND (Post Environmental): 2500 volts (rms), 60 Hz, 5 minutes WICKING: 2.25 in. (maximum) PART NUMBER: The "*" in the part numbers on page 1 shall be replaced by color code designators. 1/ Example: AWG 18, white: 44A0811-18-9 AWG 14, white with a black stripe: 44A0811-14-90 1/ See Footer section on page 1.