Tyco/P&B Circuit Breakers Mini-Mag Hydraulic-Magnetic Circuit Breakers Model W23 Pushbutton Circuit Breakers Rugged construction protects to 30 amps, to 277 volts, 60 Hz AC. Accurately calibrated to carry 100% of rated load and to trip at between 101% and 125% of load. Trip time at 200% of rated load is from 2.2 to 20 seconds. On heavy overloads, a spring-loaded iron piston moves instantly for immediate circuit interruption. Operation unaffected by ambient conditions. Terminals are 0.250" Quick Disconnect type. Humidity Resistance: per MIL-STD-202. Dielectric Strength: 1500 VAC 60 Hz. Reset Time: Instantaneous. Voltage Drop: less than 1.5 V at 1 A or more. Shock and Vibration: tested per MIL-STD-202. Operating Temperature: 40C to +85C. Insulation Resistance: 100 megs at 500 VDC. Fungus resistant. Interruption Capacity: 5-20 A N 5,000 amps; 30 A N 2,500 amps. Shipping Weight: 2.5 oz. per pole. UL recognized and CSA certified. Single-pole with trip-free mechanism. Overload condition extends button, exposing white band for visible trip indication. Meets MIL-STD: 202, method 106 N humidity; 202, method 101, test condition B N salt spray. Endurance Cycling: 6000+ at 100% rating. 10,000 mechanical cycles. Max. Operating Voltages: 50 VDC; 250 VAC (to 400 Hz). Weight: less than 2 oz. UL recognized, CSA certified. Single-Pole Stock No. Mfr.Os Type Amps 886-2061 886-2062 886-2063 886-2064 886-2084 W67-X2Q12-5 W67-X2Q12-10 W67-X2Q12-15 W67-X2Q12-20 W67-X2Q12-30 W68-X2Q12-5 W68-X2Q12-10 W68-X2Q12-15 W68-X2Q12-20 W68-X2Q12-30 EACH 1-24 25-49 50-99 5 10 15 20 30 23.22 21.60 23.00 20.38 19.33 21.12 20.53 20.90 18.68 18.21 19.16 16.42 19.16 17.25 16.90 5 10 15 20 30 51.44 55.18 44.65 55.18 55.18 45.54 50.16 42.04 50.16 50.16 39.04 45.98 39.04 45.98 45.98 EACH Stock No. Mfr.Os Type Amps Trip Time @ 200% Rating 1-24 25-49 50-99 886-2032 886-2034 886-2035 886-2036 886-2037 886-2038 886-2039 W23-X1A1G-5 W23-X1A1G-10 W23-X1A1G-15 W23-X1A1G-20 W23-X1A1G-25 W23-X1A1G-30 W23-X1A1G-50 5 10 15 20 25 30 50 6-22 seconds 6-22 seconds 6-22 seconds 6-22 seconds 6-22 seconds 6-22 seconds 6-22 seconds 19.97 19.97 19.97 19.58 19.97 19.97 16.51 18.14 18.14 18.15 17.79 18.15 18.15 14.60 16.48 16.48 16.48 16.16 16.48 16.48 12.88 Magnetic Type Circuit Breakers 6 Two-Pole 886-2065 886-2066 886-2067 886-2072 886-2073 Model W58X Push-To-Reset Type Thermal Circuit Breakers For 60 Hz AC, up to 277 V. Will carry 100% of rated load indefinitely, with ultimate trip at 125%. Trip Time: 2.2-20 seconds at 200%. Interruption Capacity: 5000 amps at 277 VAC. UL recognized. Single-Pole AC Type N Fig. A Stock No. Mfr.Os Type Amps 886-2046 886-2047 886-2048 W91-X112-10 W91-X112-15 W91-X112-20 EACH 1-24 25-49 50-99 10 15 20 31.27 25.97 20.21 28.43 24.68 18.37 26.06 23.38 16.68 10 15 20 30 50 56.52 66.16 48.43 64.86 66.16 49.97 60.14 44.03 58.96 60.14 48.39 55.13 40.37 54.05 55.13 5 10 15 20 25 30 40 50 81.98 81.98 101.62 95.64 81.98 101.62 106.53 90.95 76.13 75.96 92.38 88.62 75.96 92.38 91.94 85.37 64.15 67.09 84.68 78.27 67.09 84.68 85.37 79.68 Two-Pole AC Type N Fig. B HereOs an economical way to get low current protection. Button extends to indicate overload. Max. Operating Voltage: 250 VAC and 50 VDC. Carries 100% of rated load with ultimate trip at 145%. Tripping Time: for 1 to 4 amps is 10-45 sec. at 200%; 5 amps and up is 6-30 sec. at 200%. Dielectric Strength: over 1500 volts RMS. Voltage Drop: less than 11/2 volts. Interrupt Capacity: 2000 A at 500 VDC, 1000 A at 250 VAC. UL recognized, CSA certified. Stock No. Mfr.Os Type Amps 886-2053 886-2054 886-2055 886-2056 886-2057 886-2058 886-2059 886-2060 W58-XB1A4A-1 W58-XB1A4A-2 W58-XB1A4A-3 W58-XB1A4A-5 W58-XB1A4A-7 W58-XB1A4A-10 W58-XB1A4A-15 W58-XB1A4A-20 1 2 3 5 7 10 15 20 EACH 1-24 25-49 50-99 8.43 8.51 8.68 4.90 5.66 4.75 4.90 4.90 7.59 7.65 7.81 4.33 5.00 4.20 4.33 4.33 6.88 6.95 7.08 3.93 4.54 3.81 3.93 3.93 886-2090 886-2049 886-2050 886-2051 886-2087 W92-X112-10 W92-X112-15 W92-X112-20 W92-X112-30 W92-X112-50 Three-Pole AC Type N Fig. C 886-2068 886-2069 886-2092 886-2070 886-2071 886-2052 886-2093 886-2091 W93-X112-5 W93-X112-10 W93-X112-15 W93-X112-20 W93-X112-25 W93-X112-30 W93-X112-40 W93-X112-50 Model W28 Fuseholder-Type Thermal Circuit Breaker Single pole breakers occupy about the same space as fuseholders. Dielectric strength over 1,500 volts RMS. Max. Operating Voltages: 32 VDC, 250 VAC. Approx. Weight: 0.35 oz. (10 g). UL recognized, CSA certified. Model W31 Toggle Actuated Circuit Breakers Single pole with toggle trip lever; trip-free mechanism. Wipe-on make contacts lessen voltage drop. Meets MIL-STD 202, method 106 N humidity; 202, method 101, test condition B N salt spray. Endurance Cycling: 6000+ at 100% of rating. 10,000 mechanical cycles. Maximum Operating Voltages: 50 VDC; 250 VAC (to 400 Hz). Weight: less than 2 oz. UL recognized, CSA certified. EACH Stock No. Mfr.Os Type Amps Trip Time @ 200% Rating 1-24 25-49 50-99 886-2040 886-2041 886-2042 886-2043 886-2044 886-2045 886-2086 W31-X2M1G-5 W31-X2M1G-10 W31-X2M1G-15 W31-X2M1G-20 W31-X2M1G-25 W31-X2M1G-30 W31-X2M1G-35 5 10 15 20 25 30 35 6-22 seconds 6-22 seconds 6-22 seconds 6-22 seconds 6-22 seconds 6-22 seconds 6-22 seconds 23.37 23.37 23.61 24.86 21.46 23.81 21.25 21.26 21.26 21.48 22.71 19.68 21.83 19.48 19.48 19.48 19.48 20.64 17.98 20.16 17.99 EACH Stock No. Mfr.Os Type Amps Trip Time @ 200% of Load 1-24 25-49 50-99 886-2033 886-2074 886-2075 886-2076 886-2077 886-2078 886-2079 886-2080 886-2081 886-2082 886-2083 886-2085 886-2088 W28-XQ1A-0.50 W28-XQ1A-1 W28-XQ1A-2 W28-XQ1A-3 W28-XQ1A-4 W28-XQ1A-5 W28-XQ1A-6 W28-XQ1A-7 W28-XQ1A-8 W28-XQ1A-10 W28-XQ1A-12 W28-XQ1A-15 W28-XQ1A-20 0.50 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 10.00 12.00 15.00 20.00 4.5-28 seconds @ +25C 4.5-28 seconds @ +25C 4.5-28 seconds @ +25C 2.2-15 seconds @ +25C 2.2-15 seconds @ +25C 2.2-15 seconds @ +25C 2.2-15 seconds @ +25C 2.2-15 seconds @ +25C 2.2-15 seconds @ +25C 2.2-15 seconds @ +25C 2.2-15 seconds @ +25C 2.2-15 seconds @ +25C 2.2-15 seconds @ +25C 4.95 4.88 5.38 2.54 2.53 2.78 4.49 2.77 2.53 2.53 4.88 2.78 1.97 4.13 4.31 4.77 2.24 2.29 2.45 4.04 2.45 2.30 2.24 4.37 2.45 1.83 3.31 3.93 4.32 2.04 1.83 2.23 3.66 2.23 1.83 2.04 3.97 2.23 1.76 Prices Subject To Change N We Always Ship At The Lowest Price In Effect ALLIED c 279