Circuit Breakers
Model W28 Fuseholder-Type
Thermal Circuit Breaker
Single pole breakers occupy about the same space as
fuseholders. Dielectric strength over 1,500 volts RMS.
Max. Operating Voltages: 32 VDC, 250 VAC. Approx.
Weight: 0.35 oz. (10 g). UL recognized, CSA certified.
Model W23 Pushbutton Circuit Breakers
Single-pole with trip-free mechanism. Overload condition extends button,
exposing white band for visible trip indication. Meets MIL-STD: 202, method
106 Ñ humidity; 202, method 101, test condition B Ñ salt spray. Endurance
Cycling: 6000+ at 100% rating. 10,000 mechanical cycles. Max. Operating
Voltages: 50 VDC; 250 VAC (to 400 Hz). Weight: less than 2 oz. UL
recognized, CSA certified.
Stock Mfr.Õs Trip Time
Amps
No. Type @ 200% Rating
Model W58X Push-To-Reset Type
Thermal Circuit Breakers
Prices Subject To Change Ñ We Always Ship At The Lowest Price In Effect ALLIED
c
279
Mini-Mag Hydraulic-Magnetic Circuit Breakers
Rugged construction protects to 30 amps, to 277 volts, 60 Hz AC.
Accurately calibrated to carry 100% of rated load and to trip at
between 101% and 125% of load. Trip time at 200% of rated load is
from 2.2 to 20 seconds. On heavy overloads, a spring-loaded iron
piston moves instantly for immediate circuit interruption. Operation
unaffected by ambient conditions. Terminals are 0.250" Quick
Disconnect type. Humidity Resistance: per MIL-STD-202.
Dielectric Strength: 1500 VAC 60 Hz. Reset Time: Instantaneous.
Voltage Drop: less than 1.5 V at 1 A or more. Shock and Vibration:
tested per MIL-STD-202. Operating Temperature: Ð40°C to +85°C.
Insulation Resistance: 100 megs at 500 VDC. Fungus resistant.
Interruption Capacity: 5-20 A Ñ 5,000 amps; 30 A Ñ 2,500 amps.
Shipping Weight: 2.5 oz. per pole. UL recognized and CSA certified.
Single-Pole
EACH
886-2061 W67-X2Q12-5 5 23.22 21.12 19.16
886-2062 W67-X2Q12-10 10 21.60 20.53 16.42
886-2063 W67-X2Q12-15 15 23.00 20.90 19.16
886-2064 W67-X2Q12-20 20 20.38 18.68 17.25
886-2084 W67-X2Q12-30 30 19.33 18.21 16.90
Two-Pole
886-2065 W68-X2Q12-5 5 51.44 45.54 39.04
886-2066 W68-X2Q12-10 10 55.18 50.16 45.98
886-2067 W68-X2Q12-15 15 44.65 42.04 39.04
886-2072 W68-X2Q12-20 20 55.18 50.16 45.98
886-2073 W68-X2Q12-30 30 55.18 50.16 45.98
Stock Mfr.Õs Amps
No. Type 1-24 25-49 50-99
886-2053 W58-XB1A4A-1 1 8.43 7.59 6.88
886-2054 W58-XB1A4A-2 2 8.51 7.65 6.95
886-2055 W58-XB1A4A-3 3 8.68 7.81 7.08
886-2056 W58-XB1A4A-5 5 4.90 4.33 3.93
886-2057 W58-XB1A4A-7 7 5.66 5.00 4.54
886-2058 W58-XB1A4A-10 10 4.75 4.20 3.81
886-2059 W58-XB1A4A-15 15 4.90 4.33 3.93
886-2060 W58-XB1A4A-20 20 4.90 4.33 3.93
Stock Mfr.Õs Amps
No. Type
EACH
1-24 25-49 50-99
886-2032 W23-X1A1G-5 5 6-22 seconds 19.97 18.14 16.48
886-2034 W23-X1A1G-10 10 6-22 seconds 19.97 18.14 16.48
886-2035 W23-X1A1G-15 15 6-22 seconds 19.97 18.15 16.48
886-2036 W23-X1A1G-20 20 6-22 seconds 19.58 17.79 16.16
886-2037 W23-X1A1G-25 25 6-22 seconds 19.97 18.15 16.48
886-2038 W23-X1A1G-30 30 6-22 seconds 19.97 18.15 16.48
886-2039 W23-X1A1G-50 50 6-22 seconds 16.51 14.60 12.88
Stock Mfr.Õs Trip Time
Amps
No. Type @ 200% Rating
EACH
1-24 25-49 50-99
Magnetic Type Circuit Breakers
For 60 Hz AC, up to 277 V. Will carry 100% of rated load indefinitely, with ultimate trip at 125%. Trip
Time: 2.2-20 seconds at 200%. Interruption Capacity: 5000 amps at 277 VAC. UL recognized.
Single-Pole AC Type Ñ Fig. A
EACH
886-2046 W91-X112-10 10 31.27 28.43 26.06
886-2047 W91-X112-15 15 25.97 24.68 23.38
886-2048 W91-X112-20 20 20.21 18.37 16.68
Two-Pole AC Type Ñ Fig. B
886-2090 W92-X112-10 10 56.52 49.97 48.39
886-2049 W92-X112-15 15 66.16 60.14 55.13
886-2050 W92-X112-20 20 48.43 44.03 40.37
886-2051 W92-X112-30 30 64.86 58.96 54.05
886-2087 W92-X112-50 50 66.16 60.14 55.13
Three-Pole AC Type Ñ Fig. C
886-2068 W93-X112-5 5 81.98 76.13 64.15
886-2069 W93-X112-10 10 81.98 75.96 67.09
886-2092 W93-X112-15 15 101.62 92.38 84.68
886-2070 W93-X112-20 20 95.64 88.62 78.27
886-2071 W93-X112-25 25 81.98 75.96 67.09
886-2052 W93-X112-30 30 101.62 92.38 84.68
886-2093 W93-X112-40 40 106.53 91.94 85.37
886-2091 W93-X112-50 50 90.95 85.37 79.68
Stock Mfr.Õs Amps
No. Type 50-991-24 25-49
886-2033 W28-XQ1A-0.50 0.50 4.5-28 seconds @ +25°C4.95 4.13 3.31
886-2074 W28-XQ1A-1 1.00 4.5-28 seconds @ +25°C4.88 4.31 3.93
886-2075 W28-XQ1A-2 2.00 4.5-28 seconds @ +25°C5.38 4.77 4.32
886-2076 W28-XQ1A-3 3.00 2.2-15 seconds @ +25°C2.54 2.24 2.04
886-2077 W28-XQ1A-4 4.00 2.2-15 seconds @ +25°C2.53 2.29 1.83
886-2078 W28-XQ1A-5 5.00 2.2-15 seconds @ +25°C2.78 2.45 2.23
886-2079 W28-XQ1A-6 6.00 2.2-15 seconds @ +25°C4.49 4.04 3.66
886-2080 W28-XQ1A-7 7.00 2.2-15 seconds @ +25°C2.77 2.45 2.23
886-2081 W28-XQ1A-8 8.00 2.2-15 seconds @ +25°C2.53 2.30 1.83
886-2082 W28-XQ1A-10 10.00 2.2-15 seconds @ +25°C2.53 2.24 2.04
886-2083 W28-XQ1A-12 12.00 2.2-15 seconds @ +25°C4.88 4.37 3.97
886-2085 W28-XQ1A-15 15.00 2.2-15 seconds @ +25°C2.78 2.45 2.23
886-2088 W28-XQ1A-20 20.00 2.2-15 seconds @ +25°C1.97 1.83 1.76
Stock Mfr.Õs Trip Time
Amps
No. Type @ 200% of Load
EACH
1-24 25-49 50-99
Model W31 Toggle Actuated
Circuit Breakers
Single pole with toggle trip lever; trip-free mechanism. Wipe-on make contacts
lessen voltage drop. Meets MIL-STD 202, method 106 Ñ humidity; 202, method
101, test condition B Ñ salt spray. Endurance Cycling: 6000+ at 100% of rating.
10,000 mechanical cycles. Maximum Operating Voltages: 50 VDC; 250 VAC (to
400 Hz). Weight: less than 2 oz. UL recognized, CSA certified.
886-2040 W31-X2M1G-5 5 6-22 seconds 23.37 21.26 19.48
886-2041 W31-X2M1G-10 10 6-22 seconds 23.37 21.26 19.48
886-2042 W31-X2M1G-15 15 6-22 seconds 23.61 21.48 19.48
886-2043 W31-X2M1G-20 20 6-22 seconds 24.86 22.71 20.64
886-2044 W31-X2M1G-25 25 6-22 seconds 21.46 19.68 17.98
886-2045 W31-X2M1G-30 30 6-22 seconds 23.81 21.83 20.16
886-2086 W31-X2M1G-35 35 6-22 seconds 21.25 19.48 17.99
EACH
1-24 25-49 50-99
HereÕs an economical way to get low current protection. Button extends to indicate overload. Max.
Operating Voltage: 250 VAC and 50 VDC. Carries 100% of rated load with ultimate trip at 145%.
Tripping Time: for 1 to 4 amps is 10-45 sec. at 200%; 5 amps and up is 6-30 sec. at 200%. Dielectric
Strength: over 1500 volts RMS. Voltage Drop: less than 1
1
/
2
volts. Interrupt Capacity: 2000 A at
500 VDC, 1000 A at 250 VAC. UL recognized, CSA certified.
6