Automotive Relays Plug-in Maxi ISO Relays Shrouded Power Relay F7 A Pin assignment similar to ISO 7588 part 1 Customized versions on request - Integrated components (e.g. resistor, diode) - Customized marking/color - Special cover with bracket Typical applications Cross carline up to 70A for example: ABS control, blower fans, cooling fan, energy management, engine control, fuel pump, heated front screen, ignition, lamps: front, rear, fog light, main switch/supply relay, wiper control. F136_fcw1_bw Contact Data Contact arrangement 1 form A, 1 NO Rated voltage 12VDC Limiting continuous current 23C 70A 85C 50A 125C 30A Limiting making current1) 240A Limiting breaking current 70A Limiting short-time current 2) overload current, ISO 8820-3 1.35 x 50A, 1800s 2.00 x 50A, 5s 3.50 x 50A, 0.5s 6.00 x 50A, 0.1s Jump start test, ISO 16750-1 24VDC for 5min, conducting nominal current at 23C Contact material Silver based Min. recommended contact load3) 1A at 5VDC Initial voltage drop at 10A, form A (NO) contact, typ./max. 15/200mV Frequency of operation at nominal load 6 ops./min (0.1Hz) Operate/release time typ. 7/2ms4) Electrical endurance >2x105 ops. resistive load, NO contact 50A, 14VDC Max. DC load breaking capacity Contact Data (continued) >1x106 ops. Mechanical endurance 1) The values apply to a resistive or inductive load with suitable spark suppression and at maximum 14VDC for 12VDC or 28VDC for 24VDC load voltages. For a load current duration of maximum 3s for a make/break ratio of 1:10. 2) Current and time are compatible with circuit protection by a typical automotive fuse. Relay will make, carry and break the specified current. 3) See chapter Diagnostics of Relays in our Application Notes or consult the internet at http://relays.te.com/appnotes/ 4) For unsuppressed relay coil. A low resistive suppression device in parallel to the relay coil increases the release time and reduces the lifetime caused by increased erosion and/or higher risk of contact tack welding. Coil Data Rated coil voltage Coil versions, DC coil Coil Rated Operate code voltage voltage VDC VDC 004 12 7.2 12VDC Release voltage VDC 1.6 Coil resistance5) 10% 90 Rated coil power5) W 1.6 5) Without components in parallel. All figures are given for coil without pre-energization, at ambient temperature +23C. Coil operating range ECR0629-N 136J_OVR2 30 Umax Coil voltage in V 25 20 15 Does not ta the tempera the contact E = pre-ene Uop = oper Uop (E = 13,5 V) 10 Uop (E = 0 V) 5 0 -4 0 -2 0 0 20 40 60 80 100 120 Ambient temperature in C Load limit curve 1: arc extinguishes during transit time (changeover contact). Load limit curve 2: safe shutdown, no stationary arc (make contact). Load limit curves measured with low inductive resistors verified for 1000 switching events. 02-2017, Rev. 0217 www.te.com (c) 2017 TE Connectivity. Datasheets and product specification according to IEC 61810-1 and to be used only together with the `Definitions' section. Does not take into account the temperature rise due to the contact current E = pre-energization. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the `Definitions' section, available at http://relays.te.com/definitions Datasheets, product data, `Definitions' section, application notes and all specifications are subject to change. 1 Automotive Relays Plug-in Maxi ISO Relays Shrouded Power Relay F7 A (Continued) Insulation Data Initial dielectric strength between open contacts between contact and coil between adjacent contacts Load dump test ISO 7637-1 (12VDC), test pulse 5 ISO 7637-2 (24VDC), test pulse 5 500Vrms 500Vrms 500Vrms Vs=+86.5VDC Vs=+200VDC Other Data EU RoHS/ELV compliance compliant Protection to heat and fire according UL94 HB or better6) Ambient temperature -40 to 125C Climatic cycling with condensation, EN ISO 6988 6 cycles, storage 8/16h Temperature cycling, IEC 60068-2-14, Nb 10 cycles, -40/+85C (5C/min) Damp heat cyclic, IEC 60068-2-30, Db, Variant 1 6 cycles, upper air temp. 55C Damp heat constant, IEC 60068-2-3, Ca 56 days Category of environmental protection, IEC 61810 RT III - sealed Degree of protection, IEC 60529 IP67 (sealed) only with special connector Vibration resistance (functional) IEC 60068-2-6 (sine sweep) 10 to 500Hz, min. 10g7) Shock resistance (functional) IEC 60068-2-27 (half sine) 6ms, min. 30g7) Drop test, free fall, IEC 60068-2-32 1m onto concrete Other Data (continued) Terminal type Cover retention pull force push force Terminal retention pull force push force Weight Packaging unit plug-in, QC 150N 200N 150N 150N approx. 60g (2.1oz) 108 pcs. 6) Refers to used materials. 7) No change in the switch.ing state >10s. Valid for NC contacts, NO contact values significantly higher. Accessories For fitting connectors please contact us via online Support Center Terminal Assignment NOR 1 form A, NO with resistor 2 2 5 1 3 02-2017, Rev. 0217 www.te.com (c) 2017 TE Connectivity. Datasheets and product specification according to IEC 61810-1 and to be used only together with the `Definitions' section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the `Definitions' section, available at http://relays.te.com/definitions Datasheets, product data, `Definitions' section, application notes and all specifications are subject to change. Automotive Relays Plug-in Maxi ISO Relays Shrouded Power Relay F7 A (Continued) 0,5 6,4 3,2 4,6 0,1 0,5 Dimensions 24 39,6 0,5 54,2 TE136J_DD2 TE136_DD5 View of the terminals (bottom view) 0,5 35,2 30 6,7 10,9 TE136J_DD1 32,4 TE136J_VT1 5,5 TE136J_VT1 Product code structure TE136_BV1 Typical product code V23136 -J 1 004 -X050 Type V23136 Power Relay F7 A Contact arrangement J 1 form A, 1 NO Cover 1 Bracket at terminal 3 Coil 004 12VDC Terminal/arrangement Xnnn Customized (nnn: version number) Product code Arrangement V23136-J1004-X050 1 Form A, 1 NO Cover Standard Coil suppr. Resistor 560 Circuit1) NOR Coil 12VDC Contact materialTerminals Part number Silver based Plug-in, QC 1-1414122-0 1) See terminal assignment diagrams. Other types on request. This list represents the most common types and does not show all variants covered by this datasheet. 02-2017, Rev. 0217 www.te.com (c) 2017 TE Connectivity. Datasheets and product specification according to IEC 61810-1 and to be used only together with the `Definitions' section. Datasheets and product data is subject to the terms of the disclaimer and all chapters of the `Definitions' section, available at http://relays.te.com/definitions Datasheets, product data, `Definitions' section, application notes and all specifications are subject to change. 3