Current Internal Current Internal
rating (A) resistance () rating (A) resistance ()
0.05 442 2 0.25
0.08 173 2.5 0.19
0.1 110 3 0.12
0.2 27.8 3.5 0.09
0.3 12.4 4 0.07
0.4 7.0 5 0.05
0.5 4.5 6 0.04
0.6 3.1 7 0.02
0.7 2.3 8 0.02
0.8 1.7 10 0.02
1 1.1 12 0.02
1.2 0.71 15 0.02
1.5 0.41 16 0.02
1.8 0.38
Thermal Overcurrent Circuit Breaker 1110-...
www.e-t-a.com05/06(280405)
1
Description
Typical applications
Ordering information
Approvals
Technical data
Single pole switch/thermal circuit breaker (S-type TO CBE to EN 60934)
with tease-free, trip-free, snap action mechanism. Designed for snap-
in panel mounting utilising round hole or industry standard fuse-
holder cut-out dimensions. Featuring an ergonomically styled two
colour actuator with indicator band clearly showing the tripped/OFF
position.
Approved to CBE standard EN 60934 (IEC 60934).
Motors, transformers, solenoids, extra low voltage systems,
household and office machines, instrumentation, marine
applications, mobile homes. 1110-F1..
Authority Voltage ratings Current ratings
BV AC 250 V; DC 28 V 0.05...16 A
UL AC 250 V 0.05...6 A
AC 125 V 7...16 A
DC 50 V 0.05...16 A
CSA AC 250 V; DC 50 V 0.05...16 A
VDE AC 250 V 0.05...10 A
Standard current ratings and typical internal resistance values
Type No.
1110 snap in panel mounting
Mounting
F1 panel thickness 0.8...1.6 mm (.031 -.063 in)
F2 panel thickness 1.8...3 mm (.071-.118 in)
Number of poles
11 pole protected
Actuator style
2black push button/white indicator ring, standard
Other indicator ring colours are available to special order
Terminal design
P1 blade terminals A6.3-0.8 (QC .250)
Characteristic curve
M1 medium delay
Current ratings
0.05...16A
1110 - F1 1 2 - P1 M1 - 0.05 A = ordering example
For further details please see chapter: Technical Information
Voltage rating AC 250 V; DC 28 V
(UL: AC 250 V; DC 50 V)
Current rating 0.05...16 A
Typical life AC + DC
0.05...10 A 10,000 operations at 1 x IN, inductive
12...16 A 6,000 operations at 1 x IN, inductive
Ambient temperature -20...+60 °C (-4...+140 °F)
Insulation co-ordination rated impulse pollution
(IEC 60664 and 60664 A) withstand voltage degree
2.5 kV 2
reinforced insulation in operating area
Dielectric strength
(IEC 60664 and 60664A) test voltage
operating area AC 3,000 V
Insulation resistance > 100 M(DC 500 V)
Interrupting capacity Icn AC 250 V: 0.05...16 A 8 x IN
DC 28 V: 0.05...6 A 10 x IN
7...10 A 200 A
12...16 A 300 A
Interrupting capacity INUN
(UL 1077/EN60934 PC 1) 0.05...6 A AC 250 V 1,000 A
7...16 A AC 125 V 1,000 A
0.05...16 A DC 50 V 1,000 A
Degree of protection operating area IP40
(IEC 60529/DIN 40050) terminal area IP00
Vibration 8 g (57-500 Hz)±0.61 mm (10-57 Hz),
to IEC 60068-2-6, test Fc,
10 frequency cycles/axis
Shock 30 g (11 ms)
to IEC 60068-2-27, test Ea
Corrosion 96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
Humidity 240 hours at 95 % RH
to IEC 60068-2-3, test Ca
Mass approx. 12 g
www.e-t-a.com 05/06(280405)
Thermal Overcurrent Circuit Breaker 1110-...
1
3
mounting area
operating area
325 25
When installing the circuit breaker apply pressure on bezel only.
.118 .984
.118 .984
Dimensions Internal connection diagram
Installation drawing
+0.2
- 0.4
±0.05
±.002 +.008
- .016
+0.2
- 0.4
±0.05
.071 … .118
ON
OFF
9.5
15
12.5
19
10
2.4
47.5
9
51
12.1
19
10
15.6
blade terminals DIN 46244-A6.3-0.8
(QC .250)
13.2
black
white
When installing the circuit breaker apply pressure on bezel only.
16 0.8 … 1.6
installation
side
1.8 … 3
13.5
±0.1
±0.15
insertion force 20 N, removal force 120 N
installation
side
insertion force 40 N, removal force 120 N
.748
.394
.374
.591
2.01
.492
.476
.61
.354
1.85
.094
.520
.748
.394
.531
±.004
.630
±.006
.031 … .063
13.5
±0.1
.531
±.004
16
±0.15
.630
±.006
±.002 +.008
- .016
1110-F1.. / -F2..
Panel cut out
1110-F1..-P.M1-...A 1110-F2..-P.M1-...A
1
2
0.05 - 6 A
7 - 16 A
124
6810 20 40
Trip time in seconds
… times rated current
10000
1000
100
10
1
0.1
0.6 0.8
Typical time/current characteristics at +23°C/+73.4°F
Push button splash cover
transparent
Y 304 745 01 (IP64)
Terminal shroud
Y 305 602 01 (IP64)
When using
splash cover
please note
that the max.
panel thickness
is reduced by
0.5 mm/0.02 in. 20.5
17.8
14
60
ø4
ø14.5 1.25
.551
.807
.701
.049
.571
2.36
.157
Accessories - Water splash covers (transparent)
The time/current characteristic curve depends on the ambient temperature
prevailing. In order to eliminate nuisance tripping, please multiply the circuit
breaker current ratings by the derating factor shown below. See also
section 9 – Technical information.
Ambient temperature °F -4 +14 +32 +73.4 +104 +122 +140
°C -20 -10 0 +23 +40 +50 +60
Derating factors 0.76 0.84 0.92 1 1.08 1.16 1.24
This is a metric design and millimeter dimensions take precedence ( mm )
inch
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications
without notice is reserved.Product markings may not be exactly as the ordering codes.
Errors and omissions excepted.