SPECIFICATION
MODEL
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
BATTERY LOW
AC CURRENT (Typ.)
1000ms, 90ms/230VAC 2000ms, 90ms/115VAC at full load
24ms/230VAC 20ms/115VAC at full load
88 ~ 264VAC 124 ~ 370VDC
47 ~ 63Hz
80% 84% 84%
2.5A/115VAC 1.5A/230VAC
COLD START 23A/115VAC 45A/230VAC
<1mA / 240VAC
CH1:105 ~ 135% CH2:0.51 ~ 0.9A rated output power
CH1:15.87 ~ 18.63V
10V±0.8V 19.5V(+1.5V,-1V ) 39V±2V
CH1:31.74 ~ 37.26V CH1:62.1 ~ 72.9V
Protection type : Shut down o/p voltage, re-power on to recover
UL60950-1, TUV EN60950-1 approved
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
-10 ~ +60℃ (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-20 ~ +85℃, 10 ~ 95% RH
±0.03%/℃ (0 ~ 50℃)
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
183.3K hrs min. MIL-HDBK-217F (25℃)
199*110*50mm (L*W*H)
0.88Kg; 16pcs/15Kg/0.95CUFT
POWER FACTOR (Typ.) PF>0.92 at full load
155W Single Output with Battery Charger(UPS Function)
‧
‧
‧
‧
‧
‧
‧
■
AD-155 series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
(Note 4)
PROTECTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
℃
CH1OUTPUT NUMBER
AD-155A AD-155B AD-155C
13.8V 13.3V
CH2
27.1V
CH2
53.5V
CH2
27.6V
CH1
54V
CH1
10.5A 0.5A 0.5A 0.2A5A 2.7A
0 ~ 11.5A 0 ~ 0.5A 0 ~ 0.5A 0 ~ 0.5A0 ~ 5.5A 0 ~ 2.7A
151.55W 151.55W 156.5W
150mVp-p -------- -------- --------150mVp-p 240mVp-p
CH1: 12 ~ 14.5V CH1: 24 ~ 29V CH1: 48 ~ 58V
±2.0% -------- -------- --------
-------- -------- --------
-------- -------- --------
±1.0% ±1.0%
±0.5% ±0.5% ±0.5%
±0.5% ±0.5% ±0.5%
Protection type : AC Charging Mode : Constant current limiting, recovers automatically after fault condition is removed
UPS Mode : Protected by internal fuse
EMC IMMUNITY
EMC EMISSION
File Name:AD-155-SPEC 2017-07-14