Standard LCP-155B4xx Series
DELTA ELECTRONICS, INC.
1 Apr. 2004
Rev. 0B
www.deltaww.com
Small Form Factor Pluggable
Transceiver for Fast Ethernet, ATM,
SONET OC-3/SDH STM-1
LCP-155B4JS/LCP-155B4JSM(H/T) (15km)
LCP-155B4MSM(H/T) (40km)
FEATURES
Compliant with SFP Transceiver MSA
specification
LC-155B4Jx short-haul SONET OC-3 / SDH
STM-1 (S-1.1) Compliant
LC-155B4Mx long-haul SONET OC-3 / SDH
STM-1 (L-1.1) Compliant
Compliant with Industry Standard RFT
Electrical Connector and Cage
Single + 3.3V Power Supply and TTL Logic
Interface
EEPROM with Serial ID Functionality
Laser Class 1 Product which comply with the
requirements of IEC 60825-1 and IEC 60825-2
Duplex LC Connector interface
Description
The LCP-155xxxx series is a hot pluggable 3.3V
Small-Form-Factor transceiver module designed
expressly for high-speed communication
applications that require rates of up to
155Mbit/sec. It is compliant with the ATM,
SONET OC-3/SDH STM-1 standards, as well as
the SFP Multisource Agreement (MSA).
The LCP-155xxxx transceivers provide with the
LC receptacle that is compatible with the
industry standard LC connector. The transceiver
is also compatible with industry standard RFT
connector and cage.
The post-amplifier of the LCP-155xxxx also
includes a LOS (Loss Of Signal) circuit that
provides a TTL logic-high output when an
unusable optical signal level is detected.
The LCP-155xxxx transceiver is a Class 1 eye
safety product. The optical power levels, under
normal operation, are at eye safe level.
Applications
SONET OC-3/SDH STM-1
ATM Network
Fast Ethernet
Switch to Switch interface
Switched backplane applications
File server interface
Performance
LCP-155B4JS Data Link up to 15km in 9/125um
Signal Mode Fiber
LCP-155B4MS Data Link up to 40km in 9/125um
Signal Mode Fiber
Standard LCP-155B4xx Series
DELTA ELECTRONICS, INC.
2 Apr. 2004
Rev. 0B
www.deltaww.com
Absolute Maximum Ratings
Parameter Symbol Min. Typ. Max. Unit Note
Storage Temperature Ts -40 85 ºC
Supply Voltage VCC 0 5 V
Recommended Operating Conditions
Parameter Symbol Min. Typ. Max. Unit Note
Ambient Operating Temperature TA 0
-40 +70
+85 ºC
See order
information
for detail
Supply Voltage VCC 3.135 3.465 V
Electrical Characteristics
(VCC=3.135V to 3.465V)
Parameter Symbol Min. Typ. Max. Unit Note
Total Supply Current ICCT 250 mA
Transmitter
Transmitter Differential Input Voltage VDT 0.5 2.4 V 1
Transmitter Disable Input-High VDISH 2 VCC+0.3 V
Transmitter Disable Input-Low VDISL 0 0.8 V
Transmitter Fault Pull up Resistor RTX_FAULT 4.7 10 k 2
Transmitter Fault Output-High VTXFH 2 VCC+0.3 V
Transmitter Fault Output-Low VTXFL 0 0.8 V
Receiver
Receiver Differential Output Voltage VDR 0.37 1 2 V 3
Receiver LOS Load RRXLOS 4.7 10 k 2
LOS Output Voltage-High VLOSH 2 VCC+0.3 V
LOS Output Voltage-Low VLOSL 0 0.8 V
Output Data Rise/Fall Time tr/ tf 2.5 nsec 4
Notes:
1. Internally AC coupled and terminated to 100 Ohm differential load.
2. Pull up to VCC on host Board
3. Internally AC coupled, but requires a 100 Ohm differential termination at or internal to Serializer/
Deserializer.
4. These are 20%~80% values
Standard LCP-155B4xx Series
DELTA ELECTRONICS, INC.
3 Apr. 2004
Rev. 0B
www.deltaww.com
Optical Characteristics
(VCC=3.135V to 3.465V, Data Rate=155Mb/sec, PRBS=223-1 NRZ, 9/125µm SMF)
Parameter Symbol Min. Typ. Max. Unit Note
Transmitter
Output Optical Power (Avg.)
LCP-155B4MSM
LCP-155B4JS / LCP-155B4JSM
PO -5
-15
0
-8
dBm
Optical Extinction Ratio 10 dB
Center Wavelength λC 1263 1310 1360 nm
Spectral Width (RMS)
LCP-155B4MS
LCP-155B4JS
σ 3
5
nm
Optical Rise/Fall Time tr/tf 2 ns 1
Output Eye Compliant with Bellcore TR-NWT-000253 and ITU recommendation
G.957
Receiver
Sensitivity (Avg.)
LCP-155B4MS
LCP-155B4JS
PIN
-34
-31
dBm 2
Input Optical Wavelength λ 1310 nm
LOS-Deasserted (Avg.)
LCP-155B4MS
LCP-155B4JS
PA -34
-31
dBm
LOS-Asserted (Avg.) PD -48 dBm
LOS-Hysteresis PA-PD 0.5 dB
Overload PO -3 dBm
Notes:
1. These are unfiltered 10%~90% values
2. The sensitivity is provided at a BER of 1×10-10 or better with an input signal consisting of 155Mb/s,
223-1 PRBS and ER=9dB.
Mask of the eye diagram for the optical transmit signal
Standard LCP-155B4xx Series
DELTA ELECTRONICS, INC.
4 Apr. 2004
Rev. 0B
www.deltaww.com
SFP Transceiver Electrical Pad Layout
Pin Function Definitions
Pin Num. Name Function Plug Seq. Notes
1 VeeT Transmitter Ground 1
2 TX Fault Transmitter Fault Indication 3 Note 1
3 TX Disable Transmitter Disable 3
Note 2
Module disables on high or open
4 MOD-DEF2 Module Definition 2 3 Note 3, 2 wire serial ID interface
5 MOD-DEF1 Module Definition 1 3 Note 3, 2 wire serial ID interface
6 MOD-DEF0 Module Definition 0 3 Note 3, Grounded in Module
7 Rate Select Not Connect 3 Function not available
8 LOS Loss of Signal 3 Note 4
9 VeeR Receiver Ground 1 Note 5
10 VeeR Receiver Ground 1 Note 5
11 VeeR Receiver Ground 1 Note 5
12 RD- Inv. Received Data Out 3 Note 6
13 RD+ Received Data Out 3 Note 7
14 VeeR Receiver Ground 1 Note 5
15 VccR Receiver Power 2 3.3 ± 5%, Note 7
16 VccT Transmitter Power 2 3.3 ± 5%, Note 7
17 VeeT Transmitter Ground 1 Note 5
18 TD+ Transmit Data In 3 Note 8
19 TD- Inv. Transmit Data In 3 Note 8
20 VeeT Transmitter Ground 1 Note 5
Plug Seq.: Pin engagement sequence during hot plugging.
Standard LCP-155B4xx Series
DELTA ELECTRONICS, INC.
5 Apr. 2004
Rev. 0B
www.deltaww.com
Notes:
1) TX Fault is an open collector/drain output, which should be pulled up with a 4.7K – 10K resistor on the host
board. Pull up voltage between 2.0V and VccT, R+0.3V. When high, output indicates a laser fault of some kind.
Low indicates normal operation. In the low state, the output will be pulled to < 0.8V.
2) TX disable is an input that is used to shut down the transmitter optical output. It is pulled up within the module
with a 4.7 – 10 K resistor. Its states are:
Low (0 – 0.8V): Transmitter on
(>0.8, < 2.0V): Undefined
High (2.0 – 3.465V): Transmitter Disabled
Open: Transmitter Disabled
3) Mod-Def 0,1,2. These are the module definition pins. They should be pulled up with a 4.7K – 10Kresistor on the
host board. The pull-up voltage shall be VccT or VccR (see Section IV for further details). Mod-Def 0 is grounded
by the module to indicate that the module is present Mod-Def 1 is the clock line of two wire serial interface for
serial ID Mod-Def 2 is the data line of two wire serial interface for serial ID
4) LOS (Loss of Signal) is an open collector/drain output, which should be pulled up with a 4.7K – 10K resistor.
Pull up voltage between 2.0V and VccT, R+0.3V. When high, this output indicates the received optical power is
below the worst-case receiver sensitivity (as defined by the standard in use). Low indicates normal operation. In
the low state, the output will be pulled to < 0.8V.
5) VeeR and VeeT may be internally connected within the SFP module.
6) RD-/+: These are the differential receiver outputs. They are AC coupled 100 differential lines which should be
terminated with 100 (differential) at the user SERDES. The AC coupling is done inside the module and is thus
not required on the host board. The voltage swing on these lines will be between 370 and 2000 mV differential
(185 – 1000 mV single ended) when properly terminated.
7) VccR and VccT are the receiver and transmitter power supplies. They are defined as 3.3V ±5% at the SFP
connector pin. Maximum supply current is 300 mA. Recommended host board power supply filtering is shown
below. Inductors with DC resistance of less than 1 should be used in order to maintain the required voltage at
the SFP input pin with 3.3V supply voltage. When the recommended supply-filtering network is used, hot plugging
of the SFP transceiver module will result in an inrush current of no more than 30 mA greater than the steady state
value. VccR and VccT may be internally connected within the SFP transceiver module.
8) TD-/+: These are the differential transmitter inputs. They are AC-coupled, differential lines with 100
differential termination inside the module. The AC coupling is done inside the module and is thus not
required on the host board. The inputs will accept differential swings of 500 – 2400 mV (250 – 1200
mV single-ended), though it is recommended that values between 500 and 1200 mV differential (250 –
600 mV single-ended) be used for best EMI performance.
Standard LCP-155B4xx Series
DELTA ELECTRONICS, INC.
6 Apr. 2004
Rev. 0B
www.deltaww.com
Recommend Circuit Schematic
Laser Diode
Photo Diode
1uH
1uH
0.1uF10uF
0.1uF
0.01uF
0.01uF
0.01uF
0.01uF
0.1uF10uF
RES1
RES1
100 Ohms*
RES1 RES1 RES1
10k Ohms
100 Ohms
VCC
Protocol Vcc
SerDes ICProtocol IC
PLD / PAL Mod_def 2
Mod_def 1
Mod_def 0
3.3V
3.3V
DELTA SFP Module
Preamp &
Tx_Disable
Quantizer
Tx_Fault
TD +
TD -
VeeT
RD +
RD -
Rx_LOS
VeeR
Tx_Disable
Tx_Fault
Rx_LOS
RES1 = 4.7k to 10k Ohms
VccT
VccR
Laser Driver
* Depands on SerDes IC used
EEPROM
Standard LCP-155B4xx Series
DELTA ELECTRONICS, INC.
7 Apr. 2004
Rev. 0B
www.deltaww.com
Package Outline Drawing for Plastic Housing with Standard de-latch
Standard LCP-155B4xx Series
DELTA ELECTRONICS, INC.
8 Apr. 2004
Rev. 0B
www.deltaww.com
Package Outline Drawing for Metal Housing with Bail de-latch
Standard LCP-155B4xx Series
DELTA ELECTRONICS, INC.
9 Apr. 2004
Rev. 0B
www.deltaww.com
SFP timing parameters for SFP management
Parameter Symbol Min. Max. Unit Unit Conditions
TX_DISABLE Assert
time t_off 10
µsec
Time from rising edge of TX_DISABLE to
when the optical output falls below 10% of
nominal
TX_DISABLE
Negate time t_on 1 msec
Time from falling edge of TX_DISABLE to
when the modulated optical output rises
above 90% of nominal
Time to initialize,
including reset of
TX_FAULT
t_init 300 msec From power on or negation of TX_Fault using
TX Disable.
TX Fault Assert
Time
t_fault
100 µsec Time from fault to TX fault on.
TX_DISABLE to
reset t_rest 10
µsec Time TX Disable must be held high to reset
TX_Fault
LOS Assert Time t_loss_on 100 µsec Time from LOS state to Rx LOS assert
LOS Deassert Time t_loss_off 100 µsec Time from non-LOS state to Rx LOS deassert
Serial ID Clock Rate f_serial_clock 100 kHz
Standard LCP-155B4xx Series
DELTA ELECTRONICS, INC.
10 Apr. 2004
Rev. 0B
www.deltaww.com
SFP timing parameters:
Power on initialization of SFP transceiver, TX_DISABLE
negated
Power on initialization of SFP, TX_DISABLE asserted
Initialization during hot plugging of SFP TRANSCEIVER.
Example of initialization during hot plugging, TX_DISABLE
negated.
SFP TX_DISABLE timing during normal operation.
Detection of transmitter safety fault condition
Successful recovery from transient safety fault condition
Unsuccessful recovery from safety fault condition Timing of LOS detection
Standard LCP-155B4xx Series
DELTA ELECTRONICS, INC.
11 Apr. 2004
Rev. 0B
www.deltaww.com
LCP-155B4JS EEPROM Serial ID Memory Contents (2-Wire Address A0h)
Address Hex ASCII Address Hex ASCII Address Hex ASCII Address Hex ASCII Address Hex ASCII Address Hex ASCII
00 03 25 20 50 53 S 75 SN 100 00 125 00
01 04 26 20 51 20 76 SN 101 00 126 00
02 07 27 20 52 20 77 SN 102 00 127 00
03 00 28 20 53 20 78 SN 103 00
04 00 29 20 54 20 79 SN 104 00
05 02 30 20 55 20 80 SN 105 00
06 00 31 20 56 30 81 SN 106 00
07 00 32 20 57 30 82 SN 107 00
08 00 33 20 58 30 83 SN 108 00
09 00 34 20 59 30 84 DC Note 3 109 00
10 00 35 20 60 05 85 DC 110 00
11 03 36 00 61 1E 86 DC 111 00
12 01 37 00 62 00 87 DC 112 00
13 00 38 00 63 1F Note 1 88 DC 113 00
14 00 39 00 64 00 89 DC 114 00
15 96 40 4C L 65 1A 90 DC 115 00
16 37 41 43 C 66 05 91 DC 116 00
17 37 42 50 P 67 05 92 00 117 00
18 00 43 2D - 68 SN Note 2 93 00 118 00
19 00 44 31 1 69 SN 94 00 119 00
20 44 D 45 35 5 70 SN 95 CS2 Note 4 120 00
21 45 E 46 35 5 71 SN 96 00 121 00
22 4C L 47 42 B 72 SN 97 00 122 00
23 54 T 48 34 4 73 SN 98 00 123 00
24 41 A 49 4A J 74 SN 99 00 124 00
LCP-155B4MS EEPROM Serial ID Memory Contents (2-Wire Address A0h)
Address Hex ASCII Address Hex ASCII Address Hex ASCII Address Hex ASCII Address Hex ASCII Address Hex ASCII
00 03 25 20 50 53 S 75 SN 100 00 125 00
01 04 26 20 51 20 76 SN 101 00 126 00
02 07 27 20 52 20 77 SN 102 00 127 00
03 00 28 20 53 20 78 SN 103 00
04 00 29 20 54 20 79 SN 104 00
05 04 30 20 55 20 80 SN 105 00
06 00 31 20 56 30 81 SN 106 00
07 00 32 20 57 30 82 SN 107 00
08 00 33 20 58 30 83 SN 108 00
09 00 34 20 59 30 84 DC Note 3 109 00
10 00 35 20 60 05 85 DC 110 00
11 03 36 00 61 1E 86 DC 111 00
12 01 37 00 62 00 87 DC 112 00
13 00 38 00 63 B6 Note 1 88 DC 113 00
14 28 39 00 64 00 89 DC 114 00
15 00 40 4C L 65 1A 90 DC 115 00
16 37 41 43 C 66 05 91 DC 116 00
17 37 42 50 P 67 05 92 00 117 00
18 00 43 2D - 68 SN Note 2 93 00 118 00
19 00 44 31 1 69 SN 94 00 119 00
20 44 D 45 35 5 70 SN 95 CS2 Note 4 120 00
21 45 E 46 35 5 71 SN 96 00 121 00
22 4C L 47 42 B 72 SN 97 00 122 00
23 54 T 48 34 4 73 SN 98 00 123 00
24 41 A 49 4D M 74 SN 99 00 124 00
Notes:
1) Byte 63: Check sum of bytes 0-62.
2) Byte 68-83 (SN): Serial number.
3) Byte 84-91 (DC): Date code.
4) Byte 95 (CS2): Check sum of bytes 64-94.
Standard LCP-155B4xx Series
DELTA ELECTRONICS, INC.
12 Apr. 2004
Rev. 0B
www.deltaww.com
Regulatory Compliance
Feature Reference Performance
Electromagnetic Interference
(EMI)
FCC Class B
EN 55022 Class B (CISPR 22A)
Radio Frequency
Electromagnetic Field
EN 61000-4-3
IEC 1000-4-3
Electrostatic Discharge to the
Duplex LC Receptacle
EN 61000-4-2
IEC 1000-4-2
IEC 801.2
Electrostatic Discharge to the
Electrical Pins MIL-STD-883E Method 3015.7
(1) Satisfied with electrical
characteristics of product
spec.
(2) No physical damage
Eye Safety US FDA CDRH AEL Class 1
EN 60950: 2000
EN 60825-1: 1994+A11+A2
EN 60825-2: 2000
CDRH File # 0321539-00
TUV Certificate No. R50032471
Component Recognition Underwriters Laboratories and
Canadian Standards Association Joint
Component Recognition for Information
Technology Equipment Including
Electrical Business Equipment
UL File # E239394
Standard LCP-155B4xx Series
DELTA ELECTRONICS, INC.
13 Apr. 2004
Rev. 0B
www.deltaww.com
Ordering information for SFP modules
LCP-155X1X2X3X4X5X6
X1: Fiber
B: Single-mode 1310nm
X4: Digital Diagnostic Function
S: Standard, without digital diagnostic
function
D: Deluxe, with digital diagnostic function
X2: Power Supply Voltage and SD Level
4: 3.3V, TTL SD Level
X5: Housing Type
Blank: Plastic housing with standard
de-latch
M: Metal housing with Bail de-latch
X3: Distance
J: 15km
M: 40km
X6: Temperature
Blank: 0 to +70 degree C
T: -40 to +85 degree C
H: -10 to +85 degree C
Related Products
LCP-1250xxxx: 1.25Gb/s, Multimode and single mode transceiver from 500m to 10km
LCP-2125xxxx: 2.125Gb/s, Multimode and single mode transceiver from 300m to 10km
LCP-2488xxxx: 2.5Gb/s, multimode and single mode transceiver from 300m to 15km