1N5221-LCC3
TO
1N5281-LCC3
Semelab Ltd reserves the right to change test conditions, parameter limits and package dimensions without notice. Information furnished by Semelab is believed
to be both accurate and reliable at the time of going to press. However Semelab assumes no responsibility for any errors or omissions discovered in its use.
Semelab encourages customers to verify that datasheets are current before placing orders.
Semelab Ltd. Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
E-mail: sales@semelab.co.uk Website: http://www.semelab.co.uk
DOC 7788 issue 3
Nominal
Zener
Voltage
Test
Current
Maximum Zener Impedance(1) Maximum Reverse
Leakage Current
Maximum Zener
Voltage
Coefficient(2)
VZ @ IZT I
ZT Z
ZT @ IZK Z
ZT @ IZK = 250µA IR @ VR V
Z
V mA µA V %/°C
P/N
A & B A B,C & D A & B
1N5236 7.5 20 6.0 500 3.0 5.7 6.0 +0.058
1N5237 8.2 20 8.0 500 3.0 6.2 6.5 +0.062
1N5238 8.7 20 8.0 600 3.0 6.2 6.5 +0.065
1N5239 9.1 20 10 600 3.0 6.7 7.0 +0.068
1N5240 10 20 17 600 3.0 7.6 8.0 +0.075
1N5241 11 20 22 600 2.0 8 8.4 +0.076
1N5242 12 20 30 600 1.0 8.7 9.1 +0.077
1N5243 13 9.5 13 600 0.5 9.4 9.9 +0.079
1N5244 14 9.0 15 600 0.1 9.5 10 +0.082
1N5245 15 8.5 16 600 0.1 10.5 11 +0.082
1N5246 16 7.8 17 600 0.1 11.4 12 +0.083
1N5247 17 7.4 19 600 0.1 12.4 13 +0.084
1N5248 18 7.0 21 600 0.1 13.3 14 +0.085
1N5249 19 6.6 23 600 0.1 13.3 14 +0.086
1N5250 20 6.2 25 600 0.1 14.3 15 +0.086
1N5251 22 5.6 29 600 0.1 16.2 17 +0.087
1N5252 24 5.2 33 600 0.1 17.1 18 +0.088
1N5253 25 5.0 35 600 0.1 18.1 19 +0.089
1N5254 27 4.6 41 600 0.1 20 21 +0.090
1N5255 28 4.5 44 600 0.1 20 21 +0.091
1N5256 30 4.2 49 600 0.1 22 23 +0.091
1N5257 33 3.8 58 700 0.1 24 25 +0.092
1N5258 36 3.4 70 700 0.1 26 27 +0.093
1N5259 39 3.2 80 800 0.1 29 30 +0.094
1N5260 43 3.0 93 900 0.1 31 33 +0.095
1N5261 47 2.7 105 1000 0.1 34 36 +0.095
1N5262 51 2.5 125 1100 0.1 37 39 +0.096
1N5263 56 2.2 150 1300 0.1 41 43 +0.096
1N5264 60 2.1 170 1400 0.1 44 46 +0.097
1N5265 62 2.0 185 1400 0.1 45 47 +0.097
1N5266 68 1.8 230 1600 0.1 49 52 +0.097
1N5267 75 1.7 270 1700 0.1 53 56 +0.098
1N5268 82 1.5 330 2000 0.1 59 62 +0.098
1N5269 87 1.4 370 2200 0.1 65 68 +0.099
1N5270 91 1.4 400 2300 0.1 66 69 +0.099
1N5271 100 1.3 500 2600 0.1 72 76 +0.110
1N5272 110 1.1 750 3000 0.1 80 84 +0.110
1N5273 120 1.0 900 4000 0.1 86 91 +0.110
1N5274 130 0.95 1100 4500 0.1 94 99 +0.110
1N5275 140 0.90 1300 4500 0.1 101 106 +0.110
1N5276 150 0.85 1500 5000 0.1 108 114 +0.110
1N5277 160 0.80 1700 5500 0.1 116 122 +0.110
1N5278 170 0.74 1900 5500 0.1 123 129 +0.110
1N5279 180 0.68 2200 6000 0.1 130 137 +0.110
1N5280 190 0.66 2400 6500 0.1 137 144 +0.110
1N5281 200 0.65 2500 7000 0.1 144 152 +0.110
Notes: 1) Zener Impedance is measured to ensure a sharp knee characteristic on the breakdown curve. Derived from 50Hz ac voltage from ac current of 10% rms of IZT
(or IZK) superimposed on DC IZT (or IZK)
2) Temperature Coefficient test conditions:
a. IZT = 7.5mA , T1 = 25°C, T2 = 125°C (1N5221A, B through to 1N5242A, B)
b. IZT = 7.5mA , T1 = 25°C, T2 = 125°C (1N5243A, B through to 1N5281A, B)
DUT temperature stabilised with constant current for VZ measurement @ T1,T2