B45
Features
1. Electromagnetic Shielding Effect
This product enhances shielding effects with a metallic cover
over the ribbon cable connector (HIF3B series).
2. Screw Locking Mechanism
The locking mechanism is designed in a stubborn and
steady structure for the screw type.
3. Assembling
The ribbon cable connector (HIF3B series) can be easily
assembled.
Applications
Peripheral and termination equipment, control machines, measuring
instruments etc.
Ordering Information
Cover (HIF3B Series) against EMI (Electromagnetic Interference)
MaterialI/O Cable Termination
As shown above, bend the shield knitted cord, wind
the conductive tape 1 to 2 turns, and finish cable
termination so as not to loosen the shield knitted cord.
HIF 3 - *CVFA
qwe
qSeries Name : HIF 3
wNumber of contacts : 10, 16, 20, 26, 30, 34, 40, 50, 64
eCVFA : Cover case for EMI
Finish
Nickel plated
Material
Zinc alloy
B46
Cover
Part Number CL No.
Unit : mm
HIF3-10CVFA
HIF3-16CVFA
HIF3-20CVFA
HIF3-26CVFA
HIF3-30CVFA
HIF3-34CVFA
HIF3-40CVFA
HIF3-50CVFA
HIF3-64CVFA
612-0061-4
612-0062-7
612-0063-0
612-0064-2
612-0065-5
612-0066-8
612-0067-0
612-0068-3
612-0070-5
Number of Contacts
10
16
20
26
30
34
40
50
64
A B
8.5
7.8
9.0
10.0
9.2
11.0
13.0
14.5
15.4
8.0
7.8
8.5
9.5
9.2
10.0
10.0
10.0
10.0
C
31.7
34.9
39.98
47.6
52.68
57.76
65.38
78.08
95.86
D
38.12
41.32
46.4
54.02
59.1
64.18
71.8
84.5
102.7
E
17.52
25.14
30.22
37.84
42.92
48.0
55.62
68.32
86.1
B47
Applicable Socket Connector
Part Number CL No.
Unit : mm
Notes1 and 2: The number of polarizing guide and keys change according to products.
HIF3BA-10D-2.54R-CL(21)
HIF3BA-16D-2.54R-CL(21)
HIF3BA-20D-2.54R-CL(21)
HIF3BA-26D-2.54R-CL(21)
HIF3BA-30D-2.54R-CL(21)
HIF3BA-34D-2.54R-CL(21)
HIF3BA-40D-2.54R-CL(21)
HIF3BA-50D-2.54R-CL(21)
HIF3BB-50D-2.54R-CL(21)
HIF3BA-64D-2.54R-CL(21)
HIF3BB-64D-2.54R-CL(21)
610-0190-4-21
610-0192-0-21
610-0193-2-21
610-0194-5-21
610-0195-8-21
610-0196-0-21
610-0197-3-21
610-0198-6-21
610-0201-9-21
610-0200-6-21
610-0203-4-21
Number of Contacts
10
16
20
26
30
34
40
50
50
64
64
A B
17.27
24.89
29.97
37.59
42.67
47.75
55.37
68.07
68.07
85.85
85.85
10.16
17.78
22.86
30.48
35.56
40.64
48.26
60.96
60.96
78.74
78.74
C
11.43
19.05
24.13
31.75
36.83
41.91
49.53
62.23
62.23
80.01
80.01
D
12.8
20.42
25.5
33.12
38.2
43.28
50.9
63.6
63.6
81.38
81.38
Polarizing guide
One at center
One on right and left sides, resp.
One at center
One on right and left sides, resp
One at center
Polarizing keyway
One at center
One on right and left sides, resp.
Pin Header
The pin header applicable to the socket connector HIF series can wholly use the HIF3 series. It is recommended to
use following products, considering positioning (protection of mating area) when the connector is engaged.
In addition, when the connector is installed, the locking mechanism is removed. If needed, order the product (11)
according to the specification (unlock), as shown below.
HIF3B *PA2.54DS,DSA(11)
HIF3BA*PA2.54DS,DSA(11)
HIF3BB*PA2.54DS,DSA(11)
Note:
HIF3B*PA2.54DS, DSA (11)is limited
to number of contacts as follows:
DSA-20, 30, 34, 40 contacts
DSA-26, 50 contacts
B48
Number of Contacts
10
16
20
26
30
34
40
50
64
A
18.52
26.14
31.22
38.84
43.92
49.0
56.62
69.32
87.1
B
31.7
34.9
39.98
47.6
52.68
57.76
65.38
78.08
95.86
C
10.16
17.78
22.86
30.48
35.56
40.64
48.26
60.96
78.74
D
21.8
29.5
34.5
42.2
47.2
52.3
59.9
72.6
90.4
HIF3B-*PA-DS(11)
HIF
3BA
-*PA-DS(11)
3BB
3.45
4.75
Recommended Panel catouts
Right Angle Type
B49
Cover Assembling Procedures
BAssembling Procedures
1. Insert the connected connector (cable shield cable after termination process) 1in the adapter metal 2, and
connect the assembly to the cover A 3.
2. Insert the cable unit 1in the clamp slot of cover A 3, and mount the clamp metal 4. Then, tighten the unit by
screws.
3. Next, place the lock screw 5in the right slot, and mount the cover B 7so as not to bite the cable, and tighten the
assembly by screws. At this time, check that no clearance is found between cover A and B.
6
3
45
2
1
1
7
8
3