1
www.power-one.com
Edition 4/04.2001
Rugged electrical and mechanical design
Output 1 regulated, outputs 2 and 3 tracking
Operating ambient temperature range
–10...50°C with convection cooling
H Series 50 Watt AC-DC Converters
Input voltage range 85...255 V AC
1, 2 or 3 isolated outputs up to 48 V DC
4 kV AC I/O electric strength test voltage
Input
Input voltage continuous range 85...255 V AC
Input frequency 47...63 Hz
Inrush current limitation by thermistor
Output
Efficiency
U
i nom,
I
o nom up to 83%
Output voltage 1 setting acc.
U
i nom,
I
o nom ±2%
U
o1 nom
Output voltage 2, 3 setting acc.
U
i nom,
I
o nom ±5%
U
o2,3 nom
Output voltage switching noise IEC/EN 61204, total typ. 200 mVpp
Line regulation
U
i min...
U
i max,
I
o nom typ. ±1%
U
o nom
Load regulation output 1
U
i nom, 0...
I
o1 nom typ. 0.2%
U
o1 nom
Load regulation output 2, 3 10...100%
I
o2,3 nom typ. 0.7 V
Output voltage 2, 3
U
i nom,
I
o1 nom,
I
o2,3 = 0 max. 115%
U
o2,3 nom
Cross load regulation outp. 2, 3 0...100%
I
o1 nom typ. 0.7 V
Minimum output current not required 0 A
Current limitation main output rectangular U/I characteristic typ. 110%
I
o nom
Current limitation aux. output(s) rectangular U/I characteristic typ. 120%
I
o nom
Operation in parallel by current limitation
Hold-up time
U
i = 230 V AC,
I
o nom typ. 70 ms
Selection chart
Output 1 Output 2 Output 3 Rated power Type Options
U
o nom
I
o nom
U
o nom
I
o nom
U
o nom
I
o nom
P
o tot Input voltage
[V DC] [A] [V DC] [A] [V DC] [A] [W] 85...255 V AC
5.1 11 - - - - 56 LH 1001-2R D, V
12 6 - - - - 72 LH 1301-2R D
15 4.5 - - - - 67 LH 1501-2R D
24 3 - - - - 72 LH 1601-2R D
48 1.5 - - - - 72 LH 1901-2R D
12 2 12 2 - - 48 LH 2320-2 D
15 1.7 15 1.7 - - 51 LH 2540-2 D
5.1 5 12 0.7 12 0.7 42 LH 3020-2 D, V
5.1 5 15 0.6 15 0.6 43 LH 3040-2 D, V
LGA
2
www.power-one.com
Edition 4/04.2001
Cassette Style H Series
Protection
Input undervoltage lockout typ. 60 V AC
Input overvoltage lockout typ. 280 V AC
Input transient protection varistor
Output no-load, overload and short circuit proof
Output overvoltage suppressor diode in each output typ. 150%
U
o nom
Overtemperature switch-off with auto restart
T
C typ. 100 °C
Control
Output voltage adjustment single output types 0...110%
U
o1 nom
Inhibit TTL input, output(s) disabled if left open-circuit
Status indication LEDs: OK, inhibit
Safety
Approvals EN 60950, UL 1950, CSA C22.2 No. 950
Class of equipment class I
Protection degree units without options IP 40
Electric strength test voltage I/case 2 kV AC
I/O 4 kV AC
O/case 1 kV AC
O/O 0.2 kV AC
EMC
Electrostatic discharge IEC/EN 61000-4-2, contact discharge, level 2 (4 kV) criterion A
Electromagnetic field IEC/EN 61000-4-3, level x (20 V/m) criterion A
Electr. fast transients/bursts IEC/EN 61000-4-4, input, level 1 (0.5 kV) criterion A
Surge IEC/EN 61000-4-5, input, level 1 (0.5 kV) criterion A
Electromagnetic emissions CISPR 22/EN 55022, conducted class A
CISPR 22/EN 55022, radiated class B
Environmental
Operating ambient temperature
U
i nom,
I
o nom, convection cooled 10...50°C
Operating case temperature
T
C
U
i nom,
I
o nom 10...80°C
Storage temperature non operational 25...100°C
Damp heat IEC/EN 60068-2-3, 93 %, 40 °C 21 days
Vibration, sinusoidal IEC/EN 60068-2-6, 1060/60150 Hz 0.15 mm/2 gn
Shock IEC/EN 60068-2-27, 6 ms 15 gn
Bump IEC/EN 60068-2-29, 16 ms 10 gn
MTBF MIL-HDBK-217E, GB, 40 °C, single output types 384'000 h
Options
Input and/or output undervoltage monitoring, excludes option V D1D8
Input and/or output undervoltage monitoring (VME), excludes option D V2, V3
3
www.power-one.com
Edition 4/04.2001
Mechanical data
Tolerances ±0.3 mm (0.012") unless otherwise indicated.
European
Projection
H Series 50 Watt AC-DC Converters
111.2 (3U) (4.38")
168.5 (6.63")
127 (5")
173.7 (6.84")
20 (0.79") 6TE
25811 14 17 20 23 26 29 32
38.7 (1.52")
Measuring point for
case temperature
T
C
M 3; depth = 4 mm
(chassis mount)
2TE
OK
Inhibit i
S09050
103
68
22 (0.87")
Potentiometer
(option D or V)
4
www.power-one.com
Edition 4/04.2001
Cassette Style H Series
Pin allocation
Pin Electrical Determination LH1000 LH2000 LH3000
2 Inhibit control input i i i
5 Safe Data or ACFAIL D or V D or V D or V
8 Output voltage (positive) Vo1+ Vo3+
11 Output voltage (negative) Vo1Vo3
14 Control input + R
17 Control input G
14 Output voltage (positive) Vo2+ Vo2+
17 Output voltage (negative) Vo2Vo2
20 Output voltage (positive) Vo1+ Vo1+ Vo1+
23 Output voltage (negative) Vo1Vo1Vo1
26 Protective earth
29 AC input voltage N NN
32 AC input voltage P P P
Accessories
Front panels 19" (Schroff/Intermas)
Mating H11 connectors with screw, solder, fast-on or press-fit terminals
Connector retention facilities and code key system for connector coding
Flexible PCB for connecting the converter via an H11 connector, if mounted on a PCB
Chassis or wall mounting plates for frontal access
Universal mounting brackets for chassis or DIN-rail mounting
2/12.2000