PD 1 Form A (AQY27) VDE Flat Power-DIP4-pin type with high capacity up to 2A load current 8.8 .346 9.3 .366 3.9 .154 8.8 .346 9.3 .366 3.7 .146 mm inch 1 4 2 3 PD 1 Form A (AQY27) FEATURES TYPICAL APPLICATIONS 1. Flat-Packaged type (W) 8.8 x (D) 9.3 x (H) 3.9 mm (W) .346 x (D) .366 x (H) .154 inch 2. High capacity of continuous load current 2A (AQY272) 3. High sensitivity and low onresistance Max. 2A load can be controlled with 5mA input current. The on-resistance is low at typ. 0.11 (AQY272). * Measuring and Testing equipment * IC Testers and Board Testers * High speed inspection machines RoHS compliant TYPES Output rating* Type AC/DC dual use Part No. Package Through hole terminal Packing quantity Surface-mount terminal Load voltage Load current 60V 2.0A AQY272 AQY272A AQY272AX AQY272AZ 100V 200V 400V 1.3A 0.65A 0.35A AQY275 AQY277 AQY274 AQY275A AQY277A AQY274A AQY275AX AQY277AX AQY274AX AQY275AZ AQY277AZ AQY274AZ Tube packing style Power-DIP4-pin Tape and reel packing style Picked from the Picked from the 1/2-pin side 3/4-pin side Tube Tape and reel 1 tube contains: 50 pcs. 1 batch contains: 1,000 pcs. 1,000 pcs. * Indicate the peak AC and DC values. Note: The surface mount terminal indicator "A" and the packing style indicator "X" or "Z" are not marked on the device. RATING 1. Absolute maximum ratings (Ambient temperature: 25C 77F) Input Output Item LED forward current LED reverse voltage Peak forward current Power dissipation Load voltage (peak AC) Continuous load current Peak load current Power dissipation Total power dissipation I/O isolation voltage Temperture limits ASCTB36E 201201-T Operating Storage Symbol IF VR IFP Pin VL IL Ipeak Pout PT Viso Topr Tstg Panasonic Corporation AQY272(A) AQY275(A) AQY277(A) AQY274(A) 50 mA 5V 1A 75 mW 60 V 100 V 200 V 400 V 2.0 A 1.3 A 0.65 A 0.35 A 6.0 A 4.0 A 2.0 A 1.0 A 700 mW 750 mW 2,500 V AC -40C to +85C -40F to +185F -40C to +100C -40F to +212F Automation Controls Business Unit Remarks f = 100 Hz, Duty factor = 0.1% Peak AC, DC 100ms (1 shot), VL = DC Non-condensing at low temperatures industrial.panasonic.com/ac/e PD 1 Form A (AQY27) 2. Electrical characteristics (Ambient temperature: 25C 77F) Item Symbol Typical LED operate current Input LED dropout voltage On resistance Output VF Ron Initial I/O isolation resistance Maximum Typical Maximum Typical Maximum Typical Maximum Minimum Maximum operating speed Maximum Turn on time* Turn off time* I/O capacitance AQY275(A) AQY277(A) 1.0 mA 0.11 0.9 mA 1.25 V (1.16 V at IF = 10 mA) 1.5 V 0.23 0.7 0.18 0.34 2.46 ms 2.40 ms Toff 5.64 ms 0.22 ms IL = 100 mA VL = 10 V IF = 50 mA 2.1 IF = 10 mA, IL = Max. Within 1 s on time 1.1 3.2 1.12 ms 1.65 ms IF = 10 mA, IL = 100 mA VL = 10 V 3.88 ms IF = 5 mA, IL = 100 mA VL = 10 V 0.08 ms IF = 5 mA or 10 mA, IL = 100 mA VL = 10 V IF = 0 mA, VL = Max. 5.0 ms 5.65 ms 2.57 ms 10.0 ms 0.21 ms 0.10 ms 3.0 ms 0.8 pF Ciso Condition IL = 100 mA VL = 10 V 10 A ILeak Ton AQY274(A) 3.0 mA 0.4 mA IFoff Maximum Maximum Typical Off state leakage current Transfer characteristics IFon Maximum Minimum Typical Typical Maximum Typical LED turn off current AQY272(A) Riso 1.5 pF 1,000 M -- 0.5 cps f = 1 MHz VB = 0 V 500 V DC IF = 10 mA, Duty factor = 50% IL = Max. , VL = Max. *Turn on/Turn off time Input 90% Output 10% Toff Ton RECOMMENDED OPERATING CONDITIONS Please obey the following conditions to ensure proper device operation and resetting. Item Input LED current Symbol IF Recommended value Unit 5 to 10 mA For Dimensions. For Schematic and Wiring Diagrams. For Cautions for Use. These products are not designed for automotive use. If you are considering to use these products for automotive applications, please contact your local Panasonic Corporation technical representative. For more information. REFERENCE DATA 1. Load current vs. ambient temperature characteristics 2.-(1) On resistance vs. ambient temperature characteristics 2.-(2) On resistance vs. ambient temperature characteristics Allowable ambient temperature: -40C to +85C -40F to +185F LED current: 10 mA; Continuous load current: 2.0 A (DC) (AQY272), 1.3 A (DC) (AQY275) LED current: 10 mA; Continuous load current: 0.65 A (DC) (AQY277), 0.35 A (DC) (AQY274) 3.5 5.0 0.5 2.5 AQY272 2.0 AQY275 1.5 0.4 AQY275 0.3 0.2 On resistance, On resistance, Load current, A 3.0 4.0 AQY274 3.0 2.0 AQY272 1.0 AQY277 0.5 AQY274 0 -40 -20 0 20 40 60 8085 100 Ambient temperature, C Panasonic Corporation 0 AQY277 1.0 0.1 -40 -20 0 20 40 60 8085 Ambient temperature, C Automation Controls Business Unit 0 -40 -20 industrial.panasonic.com/ac/e 80 85 0 20 40 60 Ambient temperature, C ASCTB36E 201201-T PD 1 Form A (AQY27) 4. Turn off time vs. ambient temperature characteristics 5. LED operate vs. ambient temperature characteristics LED current: 10 mA; Load voltage: 10 V (DC); Continuous load current: 100 mA (DC) LED current: 10 mA; Load voltage: 10 V (DC); Continuous load current: 100 mA (DC) Load voltage: 10 V (DC); Continuous load current: 100 mA (DC) 1.0 8 0.8 6 AQY272 4 5 LED operate current, mA 10 Turn off time, ms Turn on time, ms 3. Turn on time vs. ambient temperature characteristics 0.6 0.4 AQY275 AQY274 2 -40 -20 0 20 40 1 AQY274 0 -40 -20 0 20 40 60 80 85 Ambient temperature, C 8085 60 AQY274 AQY272 AQY277 2 AQY275 AQY272 AQY277 0 3 AQY275 AQY277 0.2 4 Ambient temperature, C 0 -40 -20 80 85 0 20 40 60 Ambient temperature, C 6. LED turn off current vs. ambient temperature characteristics 7. LED dropout voltage vs. ambient temperature characteristics 8. Current vs. voltage characteristics of output at MOS portion Load voltage: 10 V (DC); Continuous load current: 100 mA (DC) Sample: all types; LED current: 5 to 50 mA Ambient temperature: 25C 77F 4 3 AQY272 AQY277 2 AQY274 Current, A LED dropout voltage, V LED turn off current, mA 4.0 1.5 5 1.4 1.3 50mA 30mA 20mA 10mA 5mA 1.1 -40 -20 AQY277 AQY274 0 0.5 1.0 1.5 2.0 -1.0 Voltage, V -2.0 -3.0 0 -40 -20 8085 0 20 40 60 Ambient temperature, C AQY272 AQY275 -2.0 -1.5 -1.0 -0.5 1.2 1.0 0 2.0 1.0 AQY275 1 3.0 0 20 40 60 -4.0 80 85 100 Ambient temperature, C 9.-(1) Off state leakage current vs. load voltage characteristics 9.-(2) Off state leakage current vs. load voltage characteristics 10. Turn on time vs. LED forward current characteristics Ambient temperature: 25C 77F Ambient temperature: 25C 77F Load voltage: 10 V (DC); Continuous load current: 100 mA (DC); Ambient temperature: 25C 77F 10-6 10 -9 AQY275 10-3 18 Turn on time, ms Off state leakage current, A Off state leakage current, A 20 10-3 10-6 AQY274 10-9 AQY272 12 10 AQY272 AQY275 8 4 0 100 AQY274 AQY277 2 10-12 50 Load voltage, V 0 14 6 AQY277 10-12 16 50 Load voltage, V 0 100 0 10 20 30 40 50 LED forward current, mA 12.-(1) Turn on time vs. load voltage characteristics 12.-(2) Turn on time vs. load voltage characteristics Load voltage: 10 V (DC); Continuous load current: 100 mA (DC); Ambient temperature: 25C 77F LED current: 10 mA; Continuous load current: 100 mA; Ambient temperature: 25C 77F LED current: 10 mA; Continuous load current: 100 mA; Ambient temperature: 25C 77F 5 5 0.4 4 4 0.3 AQY275 0.2 AQY277 AQY272 AQY274 0.1 0 3 AQY272 2 10 20 30 40 50 LED forward current, mA ASCTB36E 201201-T 3 2 AQY274 AQY275 1 1 0 Turn on time, ms 0.5 Turn on time, ms Turn off time, ms 11. Turn off time vs. LED forward current characteristics 0 Panasonic Corporation AQY277 0 10 20 30 40 50 60 70 80 90 100 Load voltage, V Automation Controls Business Unit 0 0 50 100 150 200 250 300 350 400 Load voltage, V industrial.panasonic.com/ac/e PD 1 Form A (AQY27) 13.-(2) Turn on time vs. load current characteristics 14.-(1) Turn off time vs. load voltage characteristics LED current: 10 mA; Load voltage: 10 V (DC); Ambient temperature: 25C 77F LED current: 10 mA; Load voltage: 10 V (DC); Ambient temperature: 25C 77F LED current: 10 mA; Continuous load current: 100 mA; Ambient temperature: 25C 77F 5 0.5 4 4 0.4 AQY275 3 AQY272 2 Turn off time, ms 5 Turn off time, ms Turn on time, ms 13.-(1) Turn on time vs. load current characteristics 3 AQY274 2 0.3 AQY272 0.2 AQY275 AQY277 1 1 0 0 0.5 1 1.5 2 2.5 Load current, A 0 3 0.1 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Load current, A 0 10 20 30 40 50 60 70 80 90 100 Load voltage, V 15.-(1) Turn off time vs. load current characteristics 15.-(2) Turn off time vs. load current characteristics LED current: 10 mA; Continuous load current: 100 mA; Ambient temperature: 25C 77F LED current: 10 mA; Load voltage 10 V (DC); Ambient temperature: 25C 77F LED current: 10 mA; Load voltage 10 V (DC); Ambient temperature: 25C 77F 0.5 0.5 0.4 0.4 0.4 0.3 0.2 Turn off time, ms 0.5 Turn off time, ms Turn off time, ms 14.-(2) Turn off time vs. load voltage characteristics 0.3 AQY272 0.2 0.3 0.2 AQY275 AQY277 0.1 0.1 0.1 AQY274 0 0 AQY274 0 50 100 150 200 250 300 350 400 Load voltage, V 0 0.5 1.0 1.5 2.0 2.5 Load current, A 3.0 17. Output capacitance vs. applied voltage characteristics Sample: All types; LED current: 10 mA; Ambient temperature: 25C 77F Frequency: 1 MHz; Ambient temperature: 25C 77F 10 1800 8 7 6 5 4 3 1600 1400 1200 1000 800 400 1 200 0 25 50 75 100 125 150 175 200 Load voltage, Vxload current, A Panasonic Corporation AQY272 600 2 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Load current, A 2000 Duty factor=50% 9 Output capacitance, pF Maximum operating frequency, time/s 16. Maximum operating frequency vs. load voltage/current characteristics 0 AQY277 0 AQY275 AQY277 0 20 AQY274 40 60 80 Applied voltage, V Automation Controls Business Unit 100 industrial.panasonic.com/ac/e ASCTB36E 201201-T Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Panasonic: AQY272AX AQY272AZ AQY274AX AQY274AZ AQY275 AQY275AX AQY275AZ AQY277 AQY277AX AQY277AZ AQY274A