FEATURES
DIRECT REPLACEMENT FOR INTERSIL ID100 & ID101
REVERSE LEAKAGE CURRENT IR = 0.1pA
REVERSE BREAKDOWN VOLTAGE BVR 30V
REVERSE CAPACITANCE Crss = 0.75pF
ABSOLUTE MAXIMUM RATINGS1
@ 25 °C (unless otherwise stated)
Maximum Temperatures
Storage Temperature -65 to +200 °C
Operating Junction Temperature -55 to +150 °C
Maximum Power Dissipation
Continuous Power Dissipation 300mW
Maximum Currents
Forward Current 20mA
Reverse Current 100µA
Maximum Voltages
Reverse Voltage 30V
Diode to Diode Voltage ±50V
ELECTRICAL CHARACTERISTICS @ 25 °C (unless otherwise stated)
SYMBOL CHARACTERISTIC MIN TYP MAX UNITS CONDITIONS
BVR Reverse Breakdown Voltage 30 IR = 1µA
VF Forward Voltage 0.8 1.1 V IF = 10mA
0.1 VR = 1V
IR Reverse Leakage Current 2.0 10
|IR1-IR2| Differential Leakage Current 3
pA VR = 10V
Crss Total Reverse Capacitance2 0.75 1 pF VR = 10V, f = 1MHz
ID100
NC
K1
NC
K2
5
BOTTOM VIEW
TO-78
1
2
3
6
7
A
1A2
ID101
NC
K1
A2
K2
3
17
5
BOTTOM VIEW
TO-71
62
A1
NC
Linear Integrated System
s
ID100 ID101
MONOLITHIC DUAL
PICO AMPERE DIODES
Linear Integrated System
s
• 4042 Clipper Court • Fremont, CA 94538 • Tel: 510 490-9160 • Fax: 510 353-0261
Figure 1. Operational Amplifier Protection
Input Differential Voltage limited to 0.8V (typ) by Diodes ID100 D1 and D2.
Common Mode Input voltage limited by Diodes ID100 D3 and D4 to ±15V.
Figure 2. Sample and Hold Circuit
Typical Sample and Hold circuit with clipping. ID100 diodes reduce offset
volta
g
es fed ca
p
acitivel
y
from the ID100 switch
g
ate.
FIGURE 1
2N4117A
R
2N4393
-V+V
V
OUT
D2D1
C
ID100
CONTROL
SIGNAL
e
in
+V
FIGURE 2
-15V+15V
OP-27
D1 D2
D3 D4
+
-
ID100
TO-78
0.335
0.370
0.305
0.335
0.016
0.019
0.165
0.185
0.040
MAX.
DIM. A
0.016
0.021
DIM. B
MIN. 0.500
0.200 0.100
0.100
0.028
0.034
45°
1235
6
7
0.029
0.045
SEATING
PLANE
TO-71
Six Lead0.230
0.209 DIA.
DIA.
0.195
0.175 0.030
MAX.
0.500 MIN.
0.150
0.115
0.019
0.016 DIA.
6 LEADS
3
2
15
6
0.046
0.036
45°
0.048
0.028
0.100 0.050
7
Linear Integrated System
s
• 4042 Clipper Court • Fremont, CA 94538 • Tel: 510 490-9160 • Fax: 510 353-0261
1. Absolute maximum ratings are limiting values above which serviceability may be impaired.
2. Design reference only, not 100% tested.
3. Pins 3 & 5 on ID100 and ID101 must not be connected, in any fashion or manner, to any circuit or node.
Information furnished by Linear Integrated Systems is believed to be accurate and reliable. However, no responsibility is assumed for its
use; nor for any infringement of patents or other rights of third parties which may result from its use. No license is granted by implicatio
otherwise under any patent or patent rights of Linear Integrated Systems.
n or