LMX2485,LMX2485E LMX2485/LMX2485E 50 MHz - 3.0 GHz High Performance Delta-Sigma Low Power Dual PLLatinum Frequency Synthesizers with 800 MHz Integer PLL Literature Number: SNAS236E LMX2485/LMX2485E 50 MHz - 3.0 GHz High Performance Delta-Sigma Low Power Dual PLLatinumTM Frequency Synthesizers with 800 MHz Integer PLL General Description The LMX2485 is a low power, high performance delta-sigma fractional-N PLL with an auxiliary integer-N PLL. The device is fabricated using National Semiconductor's advanced process. With delta-sigma architecture, fractional spurs at lower offset frequencies are pushed to higher frequencies outside the loop bandwidth. The ability to push close in spur and phase noise energy to higher frequencies is a direct function of the modulator order. Unlike analog compensation, the digital feedback technique used in the LMX2485 is highly resistant to changes in temperature and variations in wafer processing. The LMX2485 delta-sigma modulator is programmable up to fourth order, which allows the designer to select the optimum modulator order to fit the phase noise, spur, and lock time requirements of the system. Serial data for programming the LMX2485 is transferred via a three line high speed (20 MHz) MICROWIRE interface. The LMX2485 offers fine frequency resolution, low spurs, fast programming speed, and a single word write to change the frequency. This makes it ideal for direct digital modulation applications, where the N counter is directly modulated with information. The LMX2485 is available in a 24 lead 4.0 X 4.0 X 0.8 mm LLP package. Applications Cellular phones and base stations CDMA, WCDMA, GSM/GPRS, TDMA, EDGE, PDC Direct digital modulation applications Satellite and cable TV tuners WLAN Standards Features Quadruple Modulus Prescalers for Lower Divide Ratios RF PLL: 8/9/12/13 or 16/17/20/21 IF PLL: 8/9 or 16/17 Advanced Delta Sigma Fractional Compensation 12 bit or 22 bit selectable fractional modulus Up to 4th order programmable delta-sigma modulator Features for Improved Lock Times and Programming Fastlock / Cycle slip reduction Integrated time-out counter Single word write to change frequencies with Fastlock Wide Operating Range LMX2485 RF PLL: 500 MHz to 3.0 GHz LMX2485E RF PLL: 50 MHz to 3.0 GHz Useful Features Digital lock detect output Hardware and software power-down control On-chip crystal reference frequency doubler. RF phase comparison frequency up to 50 MHz 2.5 to 3.6 volt operation with ICC = 5.0 mA at 3.0 V Functional Block Diagram 20087701 PLLatinumTM is a trademark of National Semiconductor Corporation. (c) 2008 National Semiconductor Corporation 200877 www.national.com LMX2485/LMX2485E High Performance Delta-Sigma Low Power Dual PLLatinum Frequency Synthesizer February 27, 2008 LMX2485/LMX2485E Connection Diagram Top View 24-Pin LLP (SQ) 20087722 Pin Descriptions Pin # Pin Name I/O 0 GND - Ground Substrate. This is on the bottom of the package and must be grounded. Pin Description 1 CPoutRF O RF PLL charge pump output. 2 GND - RF PLL analog ground. 3 VddRF1 - RF PLL analog power supply. 4 FinRF I RF PLL high frequency input pin. 5 FinRF* I RF PLL complementary high frequency input pin. Shunt to ground with a 100 pF capacitor. 6 LE I MICROWIRE Load Enable. High impedance CMOS input. Data stored in the shift registers is loaded into the internal latches when LE goes HIGH 7 DATA I MICROWIRE Data. High impedance binary serial data input. 8 CLK I MICROWIRE Clock. High impedance CMOS Clock input. Data for the various counters is clocked into the 24 bit shift register on the rising edge 9 VddRF2 - Power supply for RF PLL digital circuitry. 10 CE I Chip Enable control pin. Must be pulled high for normal operation. 11 VddRF5 I Power supply for RF PLL circuitry. 12 Ftest/LD O Test frequency output / Lock Detect. 13 FinIF I IF PLL high frequency input pin. 14 VddIF1 - IF PLL analog power supply. 15 GND - IF PLL digital ground. 16 CPoutIF O IF PLL charge pump output 17 VddIF2 - IF PLL power supply. 18 OSCout O Buffered output of the OSCin signal. 19 ENOSC I Oscillator enable. When this is set to high, the OSCout pin is enabled regardless of the state of other pins or register bits. 20 OSCin I Input for TCXO signal. 21 NC I This pin must be left open. 22 VddRF3 - Power supply for RF PLL digital circuitry. 23 FLoutRF O RF PLL Fastlock Output. Also functions as Programmable TRI-STATE CMOS output. 24 VddRF4 - RF PLL analog power supply. www.national.com 2 Parameter Symbol Value Typ Units VCC Min -0.3 Voltage on any pin with GND = 0V Vi -0.3 VCC+0.3 V Storage Temperature Range Ts -65 +150 C Lead Temperature (Solder 4 sec.) TL +260 C Power Supply Voltage Max 4.25 V Recommended Operating Conditions Parameter VCC Min 2.5 Value Typ 3.0 Max 3.6 TA -40 25 +85 Symbol Power Supply Voltage (Note 1) Operating Temperature Units V C Note 1: "Absolute Maximum Ratings" indicate limits beyond which damage to the device may occur. "Recommended Operating Conditions" indicate conditions for which the device is intended to be functional, but do not guarantee specific performance limits. For guaranteed specifications and test conditions, see the Electrical Characteristics. The guaranteed specifications apply only for the test conditions listed. The voltage at all the power supply pins of VddRF1, VddRF2, VddRF3, VddRF4, VddRF5, VddIF1 and VddIF2 must be the same. VCC will be used to refer to the voltage at these pins and ICC will be used to refer to the sum of all currents through all these power pins. Note 2: This Device is a high performance RF integrated circuit with an ESD rating < 2 kV and is ESD sensitive. Handling and assembly of this device should only be done at ESD-free workstations. Electrical Characteristics Symbol (VCC = 3.0V; -40C TA +85C unless otherwise specified) Parameter Conditions Value Min Typ Max Units Icc PARAMETERS ICCRF Power Supply Current, RF Synthesizer IF PLL OFF RF PLL ON Charge Pump TRI-STATE 3.3 mA ICCIF IF PLL ON Power Supply Current, IF RF PLL OFF Synthesizer Charge Pump TRI-STATE 1.7 mA ICCTOTAL Power Supply Current, Entire Synthesizer IF PLL ON RF PLL ON Charge Pump TRI-STATE 5.0 mA ICCPD Power Down Current CE = ENOSC = 0V CLK, DATA, LE = 0V 1 10 A RF SYNTHESIZER PARAMETERS fFinRF Operating Frequency (Note 3) LMX2485 LMX2485 E pFinRF Input Sensitivity fCOMP Phase Detector Frequency (Note 4) RF_P = 8 500 2000 RF_P = 16 500 3000 RF_P = 8 50 2000 RF_P = 16 50 3000 500 - 3000 MHz -15 0 50 - 500 MHz (LMX2485E only) -8 8 50 RF_CPG = 0 VCPoutRF = VCC/2 ICPoutRFSRCE RF Charge Pump Source RF_CPG = 1 VCPoutRF = VCC/2 Current (Note 5) ... RF_CPG = 15 VCPoutRF = VCC/2 3 MHz dBm MHz 95 A 190 A ... A 1520 A www.national.com LMX2485/LMX2485E Absolute Maximum Ratings (Notes 1, 2) LMX2485/LMX2485E Symbol ICPoutRFSINK Parameter RF Charge Pump Sink Current (Note 5) Conditions Value Min Typ Max Units RF_CPG = 0 VCPoutRF = VCC/2 -95 A RF_CPG = 1 VCPoutRF = VCC/2 -190 A ... A -1520 A ... RF_CPG = 15 VCPoutRF = VCC/2 ICPoutRFTRI RF Charge Pump TRISTATE Current Magnitude | ICPoutRF%MIS | Magnitude of RF CP Sink VCPoutRF = VCC/2 vs. CP Source Mismatch TA = 25C | ICPoutRF%V | Magnitude of RF CP Current vs. CP Voltage | ICPoutRF%T | Magnitude of RF CP VCPoutRF = VCC/2 Current vs. Temperature 0.5 VCPoutRF VCC -0.5 2 10 nA RF_CPG > 2 3 10 % RF_CPG 2 3 13 % 2 8 % 0.5 VCPoutRF VCC -0.5 TA = 25C 4 % IF SYNTHESIZER PARAMETERS fFinIF Operating Frequency 75 800 MHz pFinIF IF Input Sensitivity -10 5 dBm fCOMP Phase Detector Frequency 10 MHz ICPoutIFSRCE IF Charge Pump Source VCPoutIF = VCC/2 Current 3.5 mA ICPoutIFSINK IF Charge Pump Sink Current VCPoutIF = VCC/2 -3.5 mA ICPoutIFTRI IF Charge Pump TRISTATE Current Magnitude 0.5 VCPoutIF VCC RF -0.5 | ICPoutIF%MIS | Magnitude of IF CP Sink VCPoutIF = VCC/2 vs. CP Source Mismatch TA = 25C | ICPoutIF%V | Magnitude of IF CP Current vs. CP Voltage | ICPoutIF%TEMP Magnitude of IF CP VCPoutIF = VCC/2 Current vs. Temperature 0.5 VCPoutIF VCC -0.5 TA = 25C 2 10 nA 1 8 % 4 10 % 4 % OSCILLATOR PARAMETERS fOSCin Oscillator Operating Frequency vOSCin Oscillator Input Sensitivity IOSCin Oscillator Input Current OSC2X = 0 5 110 MHz OSC2X = 1 5 20 MHz 0.5 VCC VP-P -100 100 A SPURS Spurs in band www.national.com (Note 6) -55 4 dBc Parameter Conditions Value Min Typ Units Max PHASE NOISE LF1HzRF RF_CPG = 0 -202 RF_CPG = 1 RF Synthesizer Normalized Phase Noise RF_CPG = 3 Contribution (Note 7) RF_CPG = 7 -202 -206 RF_CPG = 15 LF1HzIF dBc/Hz -208 -210 IF Synthesizer Normalized Phase Noise Contribution -209 dBc/Hz DIGITAL INTERFACE (DATA, CLK, LE, ENOSC, CE, Ftest/LD, FLoutRF) VIH High-Level Input Voltage VIL Low-Level Input Voltage IIH High-Level Input Current VIH = VCC IIL Low-Level Input Current VIL = 0 V VOH High-Level Output Voltage IOH = -500 A VOL Low-Level Output Voltage IOL = 500 A 1.6 VCC V 0.4 V -1.0 1.0 A -1.0 1.0 A VCC-0.4 V 0.4 V MICROWIRE INTERFACE TIMING tCS Data to Clock Set Up Time tCH tCWH See MICROWIRE Input Timing 25 ns Data to Clock Hold Time See MICROWIRE Input Timing 8 ns Clock Pulse Width High See MICROWIRE Input Timing 25 ns tCWL Clock Pulse Width Low See MICROWIRE Input Timing 25 ns tES Clock to Load Enable Set See MICROWIRE Input Timing Up Time 25 ns tEW Load Enable Pulse Width See MICROWIRE Input Timing 25 ns Note 3: A slew rate of at least 100 V/uS is recommended for frequencies below 500 MHz for optimal performance. Note 4: For Phase Detector Frequencies above 20 MHz, Cycle Slip Reduction (CSR) may be required. Legal divide ratios are also required. Note 5: Refer to table in Section 2.4.2 RF_CPG -- RF PLL Charge Pump Gain for complete listing of charge pump currents. Note 6: In order to measure the in-band spur, the fractional word is chosen such that when reduced to lowest terms, the fractional numerator is one. The spur offset frequency is chosen to be the comparison frequency divided by the reduced fractional denominator. The loop bandwidth must be sufficiently wide to negate the impact of the loop filter. Measurement conditions are: Spur Offset Frequency = 10 kHz, Loop Bandwidth = 100 kHz, Fraction = 1/2000, Comparison Frequency = 20 MHz, RF_CPG = 7, DITH = 0, and a 4th Order Modulator (FM = 0). These are relatively consistent over tuning range. Note 7: Normalized Phase Noise Contribution is defined as: LN(f) = L(f) - 20log(N) - 10log(fCOMP) where L(f) is defined as the single side band phase noise measured at an offset frequency, f, in a 1 Hz Bandwidth. The offset frequency, f, must be chosen sufficiently smaller than the PLL loop bandwidth, yet large enough to avoid substantial phase noise contribution from the reference source. Measurement conditions are: Offset Frequency = 11 kHz, Loop Bandwidth = 100 kHz for RF_CPG = 7, Fraction = 1/2000, Comparison Frequency = 20 MHz, FM = 0, DITH = 0. MICROWIRE INPUT TIMING DIAGRAM 20087775 5 www.national.com LMX2485/LMX2485E Symbol LMX2485/LMX2485E Typical Performance Characteristics : Sensitivity (Note 8) RF PLL Fin Sensitivity TA = 25C, RF_P = 16 20087745 RF PLL Fin Sensitivity VCC = 3.0 V, RF_P = 16 20087746 www.national.com 6 LMX2485/LMX2485E IF PLL Fin Sensitivity TA = 25C, IF_P = 16 20087747 IF PLL Fin Sensitivity VCC = 3.0 V, IF_P = 16 20087748 7 www.national.com LMX2485/LMX2485E OSCin Sensitivity TA = 25C, OSC_2X = 0 20087749 OSCin Sensitivity VCC = 3.0 V, OSC_2X = 0 20087756 www.national.com 8 LMX2485/LMX2485E OSCin Sensitivity TA = 25C, OSC_2X = 1 20087773 OSCin Sensitivity VCC = 3.0 V, OSC_2X = 1 20087774 9 www.national.com LMX2485/LMX2485E Typical Performance Characteristic : FinRF Input Impedance (Note 8) 20087768 FinRF Input Impedance www.national.com Frequency (MHz) Real (Ohms) Imaginary (Ohms) 50 670 -276 100 531 -247 200 452 -209 300 408 -212 400 373 -222 500 337 -231 600 302 -237 700 270 -239 800 241 -236 900 215 -231 1000 192 -221 1100 172 -218 1200 154 -209 1300 139 -200 1400 127 -192 1500 114 -184 1600 104 -175 1700 96 -168 1800 88 -160 1900 80 -153 2000 74 -147 2200 64 -134 2400 56 -123 2600 50 -113 2800 45 -103 3000 39 -94 3200 37 -86 3400 33 -78 3600 30 -72 3800 28 -69 4000 26 -66 10 LMX2485/LMX2485E Typical Performance Characteristic : FinIF Input Impedance (Note 8) 20087754 FinIF Input Impedance Frequency (MHz) Real (Ohms) Imaginary (Ohms) 50 583 -286 75 530 -256 100 499 -241 200 426 -209 300 384 -209 400 347 -219 500 310 -224 600 276 -228 700 244 -228 800 216 -223 900 192 -218 1000 173 -208 11 www.national.com LMX2485/LMX2485E Typical Performance Characteristic : OSCin Input Impedance (Note 8) 20087755 Frequency (MHz) Powered Up Powered Down Real Imaginary Magnitude Real Imaginary Magnitude 5 1730 -3779 4157 392 -8137 8146 10 846 -2236 2391 155 -4487 4490 20 466 -1196 1284 107 -2215 2217 30 351 -863 932 166 -1495 -1504 40 316 -672 742 182 -1144 1158 50 278 -566 631 155 -912 925 60 261 -481 547 153 -758 774 70 252 -425 494 154 -652 669 80 239 -388 456 147 -576 595 90 234 -358 428 145 -518 538 100 230 -337 407 140 -471 492 110 225 -321 392 138 -436 458 120 219 -309 379 133 -402 123 130 214 -295 364 133 -374 397 140 208 -285 353 132 -349 373 150 207 -279 348 133 -329 355 www.national.com 12 LMX2485/LMX2485E Typical Performance Characteristics : Currents (Note 8) Power Supply Current CE = High 20087759 Power Supply Current CE = LOW 20087761 13 www.national.com LMX2485/LMX2485E RF PLL Charge Pump Current VCC = 3.0 Volts 20087767 IF PLL Charge Pump Current VCC = 3.0 Volts 20087765 www.national.com 14 LMX2485/LMX2485E Charge Pump Leakage RF PLL VCC = 3.0 Volts 20087764 Charge Pump Leakage IF PLL VCC = 3.0 Volts 20087763 Note 8: Typical performance characteristics do not imply any sort of guarantee. Guaranteed specifications are in the electrical characteristics section. 15 www.national.com LMX2485/LMX2485E Bench Test Setups 20087769 Charge Pump Current Measurement Procedure The above block diagram shows the test procedure for testing the RF and IF charge pumps. These tests include absolute current level, mismatch, and leakage measurement. In order to measure the charge pump currents, a signal is applied to the high frequency input pins. The reason for this is to guarantee that the phase detector gets enough transitions in order to be able to change states. If no signal is applied, it is possible that the charge pump current reading will be low due to the fact that the duty cycle is not 100%. The OSCin Pin is tied to the supply. The charge pump currents can be measured by simply programming the phase detector to the necessary polarity. For instance, in order to measure the RF charge pump, a 10 MHz signal is applied to the FinRF pin. The source current can be measured by setting the RF PLL phase detector to a positive polarity, and the sink current can be measured by setting the phase detector to a negative polarity. The IF PLL currents can be measured in a similar way. Note that the magnitude of the RF PLL charge pump current is controlled by the RF_CPG bit. Once the charge pump currents are known, the mismatch can be calculated as well. In order to measure leakage, the charge pump is set to a TRI-STATE mode by enabling the RF_CPT and IF_CPT bits. The table below shows a summary of the various charge pump tests. Current Test RF_CPG RF_CPP RF_CPT IF_CPP IF_CPT RF Source 0 to 15 0 0 X X RF Sink 0 to 15 1 0 X X RF TRI-STATE X X 1 X X IF Source X X X 0 0 IF Sink X X X 1 0 IF TRI-STATE X X X X 1 www.national.com 16 LMX2485/LMX2485E Charge Pump Current Specification Definitions 20087750 I1 = Charge Pump Sink Current at VCPout = Vcc - V I2 = Charge Pump Sink Current at VCPout = Vcc/2 I3 = Charge Pump Sink Current at VCPout = V I4 = Charge Pump Source Current at VCPout = Vcc - V I5 = Charge Pump Source Current at VCPout = Vcc/2 I6 = Charge Pump Source Current at VCPout = V Charge Pump Sink Current vs. Charge Pump Output Source Current Mismatch 20087752 V = Voltage offset from the positive and negative supply rails. Defined to be 0.5 volts for this part. vCPout refers to either VCPoutRF or VCPoutIF ICPout refers to either ICPoutRF or ICPoutIF Charge Pump Output Current Magnitude Variation vs. Temperature Charge Pump Output Current Magnitude Variation vs. Charge Pump Output Voltage 20087753 20087751 17 www.national.com LMX2485/LMX2485E 20087770 Frequency Input Pin DC Blocking Capacitor Corresponding Counter Default Counter Value MUX Value OSCin 1000 pF FinRF 100 pF// 1000 pF RF_R / 2 50 14 RF_N / 2 502 + 2097150 / 4194301 15 FinIF OSCin 100 pF IF_N / 2 534 13 1000 pF IF_R / 2 50 12 Sensitivity Measurement Procedure Sensitivity is defined as the power level limits beyond which the output of the counter being tested is off by 1 Hz or more of its expected value. It is typically measured over frequency, voltage, and temperature. In order to test sensitivity, the MUX [3:0] word is programmed to the appropriate value. The counter value is then programmed to a fixed value and a frequency counter is set to monitor the frequency of this pin. The expected frequency at the Ftest/LD pin should be the signal generator frequency divided by twice the corresponding counter value. The factor of two comes in because the LMX2485 has a flip-flop which divides this frequency by two to make the duty cycle 50% in order to make it easier to read with the frequency counter. The frequency counter input impedance should be set to high impedance. In order to perform the measurement, the temperature, frequency, and voltage is set to a fixed value and the power level of the signal is varied. Note that the power level at the part is assumed to be www.national.com 4 dB less than the signal generator power level. This accounts for 1 dB for cable losses and 3 dB for the pad. The power level range where the frequency is correct at the Ftest/LD pin to within 1 Hz accuracy is recorded for the sensitivity limits. The temperature, frequency, and voltage can be varied in order to produce a family of sensitivity curves. Since this is an openloop test, the charge pump is set to TRI-STATE and the unused side of the PLL (RF or IF) is powered down when not being tested. For this part, there are actually four frequency input pins, although there is only one frequency test pin (Ftest/ LD). The conditions specific to each pin are shown in above table. Note that for the RF N counter, a fourth order fractional modulator is used in 22-bit mode with a fraction of 2097150 / 4194301 is used. The reason for this long fraction is to test the RF N counter and supporting fractional circuitry as completely as possible. 18 LMX2485/LMX2485E 20087771 Input Impedance Measurement Procedure The above block diagram shows the test setup used for measuring the input impedance for the LMX2485. The DC blocking capacitor used between the input SMA connector and the pin being measured must be changed to a zero Ohm resistor. This procedure applies to the FinRF, FinIF, and OSCin pins. The basic test procedure is to calibrate the network analyzer, ensure that the part is powered up, and then measure the input impedance. The network analyzer can be calibrated by using either calibration standards or by soldering resistors directly to the evaluation board. An open can be implemented by putting no resistor, a short can be implemented by soldering a zero ohm resistor as close as possible to the pin being measured, and a short can be implemented by soldering two 100 ohm resistors in parallel as close as possible to the pin being measured. Calibration is done with the PLL removed from the PCB. This requires the use of a clamp down fixture that may not always be generally available. If no clamp down fixture is available, then this procedure can be done by calibrating up to the point where the DC blocking capacitor usu- ally is, and then implementing port extensions with the network analyzer. Zero ohm resistor is added back for the actual measurement. Once the setup is calibrated, it is necessary to ensure that the PLL is powered up. This can be done by toggling the power down bits (RF_PD and IF_PD) and observing that the current consumption indeed increases when the bit is disabled. Sometimes it may be necessary to apply a signal to the OSCin pin in order to program the part. If this is necessary, disconnect the signal once it is established that the part is powered up. It is useful to know the input impedance of the PLL for the purposes of debugging RF problems and designing matching networks. Another use of knowing this parameter is make the trace width on the PCB such that the input impedance of this trace matches the real part of the input impedance of the PLL frequency of operation. In general, it is good practice to keep trace lengths short and make designs that are relatively resistant to variations in the input impedance of the PLL. 19 www.national.com LMX2485/LMX2485E Functional Description erences available, such as the one given at the end of the functional description block. (Note 9) 1.0 GENERAL The LMX2485 consists of integrated N counters, R counters, and charge pumps. The TCXO, VCO and loop filter are supplied external to the chip. The various blocks are described below. 1.5 N COUNTERS AND HIGH FREQUENCY INPUT PINS The N counter divides the VCO frequency down to the comparison frequency. Because prescalers are used, there are limitations on how small the N value can be. The N counters are discussed in greater depth in the programming section. Since the input pins to these counters ( FinRF and FinIF ) are high frequency, layout considerations are important. High Frequency Input Pins, FinRF and FinIF It is generally recommended that the VCO output go through a resistive pad and then through a DC blocking capacitor before it gets to these high frequency input pins. If the trace length is sufficiently short ( < 1/10th of a wavelength ), then the pad may not be necessary, but a series resistor of about 39 ohms is still recommended to isolate the PLL from the VCO. The DC blocking capacitor should be chosen at least to be 27 pF, depending on frequency. It may turn out that the frequency is above the self-resonant frequency of the capacitor, but since the input impedance of the PLL tends to be capacitive, it actually is a benefit to exceed the tune frequency. The pad and the DC blocking capacitor should be placed as close to the PLL as possible Complementary High Frequency Pin, FinRF* These inputs may be used to drive the PLL differentially, but it is very common to drive the PLL in a single ended fashion. A shunt capacitor should be placed at the FinRF* pin. The value of this capacitor should be chosen such that the impedance, including the ESR of the capacitor, is as close to an AC short as possible at the operating frequency of the PLL. 100 pF is a typical value, depending on frequency. 1.1 TCXO, OSCILLATOR BUFFER, AND R COUNTER The oscillator buffer must be driven single-ended by a signal source, such as a TCXO. The OSCout pin is included to provide a buffered output of this input signal and is active when the OSC_OUT bit is set to one. The ENOSC pin can be also pulled high to ensure that the OSCout pin is active, regardless of the status of the registers in the LMX2485. The R counter divides this TXCO frequency down to the comparison frequency. 1.2 PHASE DETECTOR The maximum phase detector operating frequency for the IF PLL is straightforward, but it is a little more involved for the RF PLL since it is fractional. The maximum phase detector frequency for the LMX2485 RF PLL is 50 MHz. However, this is not possible in all circumstances due to illegal divide ratios of the N counter. The crystal reference frequency also limits the phase detector frequency, although the doubler helps with this limitation. There are trade-offs in choosing the phase detector frequency. If this frequency is run higher, then phase noise will be lower, but lock time may be increased due to cycle slipping and the capacitors in the loop filter may become rather large. 1.3 CHARGE PUMP For the majority of the time, the charge pump output is high impedance, and the only current through this pin is the TriState leakage. However, it does put out fast correction pulses that have a width that is proportional to the phase error presented at the phase detector. The charge pump converts the phase error presented at the phase detector into a correction current. The magnitude of this current is theoretically constant, but the duty cycle is proportional to the phase error. For the IF PLL, this current is not programmable, but for the RF PLL it is programmable in 16 steps. Also, the RF PLL allows for a higher charge pump current to be used when the PLL is locking in order to reduce the lock time. 1.6 POWER PINS, POWER DOWN, AND POWER UP MODES It is recommended that all of the power pins be filtered with a series 18 ohm resistor and then placing two capacitors shunt to ground, thus creating a low pass filter. Although it makes sense to use large capacitor values in theory, the ESR ( Equivalent Series Resistance ) is greater for larger capacitors. For optimal filtering minimize the sum of the ESR and theoretical impedance of the capacitor. It is therefore recommended to provide two capacitors of very different sizes for the best filtering. 1 F and 100 pF are typical values. The small capacitor should be placed as close as possible to the pin. The power down state of the LMX2485 is controlled by many factors. The one factor that overrides all other factors is the CE pin. If this pin is low, the part will be powered down. Asserting a high logic level on this pin is necessary to power up the chip, however, there are other bits in the programming registers that can override this and put the PLL back in a power down state. Provided that the voltage on the CE pin is high, programming the RF_PD and IF_PD bits to zero guarantees that the part will be powered up. Programming either one of these bits to one will power down the appropriate section of the synthesizer, provided that the ATPU bit does not override this. 1.4 LOOP FILTER The loop filter design can be rather involved. In addition to the regular constraints and design parameters, delta-sigma PLLs have the additional constraint that the order of the loop filter should be one greater than the order of the delta sigma modulator. This rule of thumb comes from the requirement that the loop filter must roll off the delta sigma noise at 20 dB/decade faster than it rises. However, since the noise can not have infinite power, it must eventually roll off. If the loop bandwidth is narrow, this requirement may not be necessary. For the purposes of discussion in this datasheet, the pole of the loop filter at 0 Hz is not counted. So a second order filter has 3 components, a 3rd order loop filter has 5 components, and the 4th order loop filter has 7 components. Although a 5th order loop filter is theoretically necessary for use with a 4th order modulator, typically a 4th order filter is used in this case. The loop filter design, especially for higher orders can be rather involved, but there are many simulation tools and ref- www.national.com 20 RF_PD ATPU Bit Enabled + Write to RF N Counter PLL State Low X X Powered Down (Asynchronous) High X Yes Powered Up High 0 No Powered Up High 1 No Powered Down ( Asynchronous ) LMX2485/LMX2485E CE Pin 1.7 DIGITAL LOCK DETECT OPERATION The RF PLL digital lock detect circuitry compares the difference between the phase of the inputs of the phase detector to a RC generated delay of . To indicate a locked state (Lock = HIGH) the phase error must be less than the RC delay for 5 consecutive reference cycles. Once in lock (Lock = HIGH), the RC delay is changed to approximately . To indicate an out of lock state (Lock = LOW), the phase error must become greater . The values of and are dependent on which PLL is used and are shown in the table below: RF 10 ns 20 ns IF 15 ns 30 ns PLL When the PLL is in the power down mode and the Ftest/LD pin is programmed for the lock detect function, it is forced LOW. The accuracy of this circuit degrades at higher comparison frequencies. To compensate for this, the DIV4 word should be set to one if the comparison frequency exceeds 20 MHz. The function of this word is to divide the comparison frequency presented to the lock detect circuit by 4. Note that if the MUX[3:0] word is set such as to view lock detect for both PLLs, an unlocked (LOW) condition is shown whenever either one of the PLLs is determined to be out of lock. 20087704 21 www.national.com LMX2485/LMX2485E 1.8 CYCLE SLIP REDUCTION AND FASTLOCK The LMX2485 offers both cycle slip reduction (CSR) and Fastlock with timeout counter support. This means that it requires no additional programming overhead to use them. It is generally recommended that the charge pump current in the steady state be 8X or less in order to use cycle slip reduction, and 4X or less in steady state in order to use Fastlock. The next step is to decide between using Fastlock or CSR. This determination can be made based on the ratio of the comparison frequency ( fCOMP ) to loop bandwidth ( BW ). Comparison Frequency ( fCOMP ) Fastlock 1.8.1 Using Cycle Slip Reduction (CSR) to Avoid Cycle Slipping Once it is decided that CSR is to be used, the cycle slip reduction factor needs to be chosen. The available factors are 1/2, 1/4, and 1/16. In order to preserve the same loop characteristics, it is recommended that the following constraint be satisfied: (Fastlock Charge Pump Current) / (Steady State Charge Pump Current) = CSR In order to satisfy this constraint, the maximum charge pump current in steady state is 8X for a CSR of 1/2, 4X for a CSR of 1/4, and 1X for a CSR of 1/16. Because the PLL phase noise is better for higher charge pump currents, it makes sense to choose CSR only as large as necessary to prevent cycle slipping. Choosing it larger than this will not improve lock time, and will result in worse phase noise. Consider an example where the desired loop bandwidth in steady state is 100 kHz and the comparison frequency is 20 MHz. This yields a ratio of 200. Cycle slipping may be present, but would not be too severe if it was there. If a CSR factor of 1/2 is used, this would reduce the ratio to 100 during frequency acquisition, which is probably sufficient. A charge pump current of 8X could be used in steady state, and a factor of 16X could be used during frequency acquisition. This yields a ratio of 1/2, which is equal to the CSR factor and this satisfies the above constraint. In this circumstance, it could also be decided to just use 16X charge pump current all the time, since it would probably have better phase noise, and the degradation in lock time would not be too severe. Cycle Slip Reduction ( CSR ) fCOMP 1.25 MHz Noticeable better Likely to provide a than CSR benefit, provided 1.25 MHz < fCOMP Marginally better that fCOMP > 100 X BW than CSR 2 MHz fCOMP > 2 MHz Same or worse than CSR Cycle Slip Reduction (CSR) Cycle slip reduction works by reducing the comparison frequency during frequency acquisition while keeping the same loop bandwidth, thereby reducing the ratio of the comparison frequency to the loop bandwidth. In cases where the ratio of the comparison frequency exceeds about 100 times the loop bandwidth, cycle slipping can occur and significantly degrade lock times. The greater this ratio, the greater the benefit of CSR. This is typically the case of high comparison frequencies. In circumstances where there is not a problem with cycle slipping, CSR provides no benefit. There is a glitch when CSR is disengaged, but since CSR should be disengaged long before the PLL is actually in lock, this glitch is not an issue. A good rule of thumb for CSR disengagement is to do this at the peak time of the transient response. Because this time is typically much sooner than Fastlock should be disengaged, it does not make sense to use CSR and Fastlock in combination. Fastlock Fastlock works by increasing the loop bandwidth only during frequency acquisition. In circumstances where the comparison frequency is less than or equal to 2 MHz, Fastlock may provide a benefit beyond what CSR can offer. Since Fastlock also reduces the ratio of the comparison frequency to the loop bandwidth, it may provide a significant benefit in cases where the comparison frequency is above 2 MHz. However, CSR can usually provide an equal or larger benefit in these cases, and can be implemented without using an additional resistor. The reason for this restriction on frequency is that Fastlock has a glitch when it is disengaged. As the time of engagement for Fastlock decreases and becomes on the order of the fast lock time, this glitch grows and limits the benefits of Fastlock. This effect becomes worse at higher comparison frequencies. There is always the option of reducing the comparison frequency at the expense of phase noise in order to satisfy this constraint on comparison frequency. Despite this glitch, there is still a net improvement in lock time using Fastlock in these circumstances. When using Fastlock, it is also recommended that the steady state charge pump state be 4X or less. Also, Fastlock was originally intended only for second order filters, so when implementing it with higher order filters, the third and fourth poles can not be too close in, or it will not be possible to keep the loop filter well optimized when the higher charge pump current and Fastlock resistor are engaged. www.national.com 1.8.2 Using Fastlock to Improve Lock Times 20087740 Once it is decided that Fastlock is to be used, the loop bandwidth multiplier, K, is needed in order to determine the theoretical impact of Fastlock on the loop bandwidth and the resistor value, R2p, that is switched in parallel during Fastlock. This ratio is calculated as follows: K = ( Fastlock Charge Pump Current ) / ( Steady State Charge Pump Current ) K Loop Bandwidth R2p Value Lock Time 1 1.00 X Open 100 % 2 1.41 X R2/0.41 71 % 3 1.73 X R2/0.73 58% 4 2.00 X R2 50% 8 2.83 X R2/1.83 35% 9 3.00 X R2/2 33% 16 4.00 X R2/3 25% The above table shows how to calculate the Fastlock resistor and theoretical lock time improvement, once the ratio , K, is known. This all assumes a second order filter (not counting the pole at 0 Hz). However, it is generally recommended that the loop filter order be one greater than the order of the delta sigma modulator, which means that a second order filter is 22 The first step to do is choose FM, for the delta sigma modulator order. It is recommended to start with FM = 3 for a third order modulator and use strong dithering. In general, there is a trade-off between primary and sub-fractional spurs. Choosing the highest order modulator (FM = 0 for 4th order) typically provides the best primary fractional spurs, but the worst subfractional spurs. Choosing the lowest modulator order (FM = 2 for 2nd order), typically gives the worst primary fractional spurs, but the best sub-fractional spurs. Choosing FM = 3, for a 3rd order modulator is a compromise. The second step is to choose DITH, for dithering. Dithering has a very small impact on primary fractional spurs, but a much larger impact on sub-fractional spurs. The only problem is that it can add a few dB of phase noise, or even more if the loop bandwidth is very wide. Disabling dithering (DITH = 0), provides the best phase noise, but the sub-fractional spurs are worst (except when the fractional numerator is 0, and in this case, they are the best). Choosing strong dithering (DITH = 2) significantly reduces sub-fractional spurs, if not eliminating them completely, but adds the most phase noise. Weak dithering (DITH = 1) is a compromise. The third step is to tinker with the fractional word. Although 1/10 and 400/4000 are mathematically the same, expressing fractions with much larger fractional numerators often improve the fractional spurs. Increasing the fractional denominator only improves spurs to a point. A good practical limit could be to keep the fractional denominator as large as possible, but not to exceed 4095, so it is not necessary to use the extended fractional numerator or denominator. This steps can be done in different orders and it might take a few iterations to find the optimum performance. Special considerations should be taken for lower frequencies that are below about 100 MHz. In addition squaring up the wave, it is often helpful to use lowest terms fractions instead of highest terms fractions. Also, dithering may turn out to not be so useful. All the things are to introduce a methodical way of thinking about optimizing spurs, not an exact method. There will be exceptions to all these rules. 1.8.3 Capacitor Dielectric Considerations for Lock Time The LMX2485 has a high fractional modulus and high charge pump gain for the lowest possible phase noise. One consideration is that the reduced N value and higher charge pump may cause the capacitors in the loop filter to become larger in value. For larger capacitor values, it is common to have a trade-off between capacitor dielectric quality and physical size. Using film capacitors or NPO/COG capacitors yields the best possible lock times, where as using X7R or Z5R capacitors can increase lock time by 0 - 500%. However, it is a general tendency that designs that use a higher compare frequency tend to be less sensitive to the effects of capacitor dielectrics. Although the use of lesser quality dielectric capacitors may be unavoidable in many circumstances, allowing a larger footprint for the loop filter capacitors, using a lower charge pump current, and reducing the fractional modulus are all ways to reduce capacitor values. Capacitor dielectrics have very little impact on phase noise and spurs. 1.9 FRACTIONAL SPUR AND PHASE NOISE CONTROLS Control of the fractional spurs is more of an art than an exact science. The first differentiation that needs to be made is between primary fractional and sub-fractional spurs. The primary fractional spurs are those that occur at increments of the channel spacing only. The sub-fractional spurs are those that occur at a smaller resolution than the channel spacing, usually one-half or one-fourth. There are trade-offs between fractional spurs, sub-fractional spurs, and phase noise. The rules of thumb presented in this section are just that. There will be exceptions. The bits that impact the fractional spurs are FM and DITH, and these bits should be set in this order. Note 9: For more information concerning delta-sigma PLLs, loop filter design, cycle slip reduction, Fastlock, and many other topics, visit wireless.national.com. Here there is the EasyPLL simulation tool and an online reference called "PLL Performance, Simulation, and Design", by Dean Banerjee. 23 www.national.com LMX2485/LMX2485E never recommended. In this case, the value for R2p is typically about 80% of what it would be for a second order filter. Because the Fastlock disengagement glitch gets larger and it is harder to keep the loop filter optimized as the K value becomes larger, designing for the largest possible value for K usually, but not always yields the best improvement in lock time. To get a more accurate estimate requires more simulation tools, or trial and error. LMX2485/LMX2485E Programming Description 2.0 GENERAL PROGRAMMING INFORMATION The 24-bit data registers are loaded through a MICROWIRE Interface. These data registers are used to program the R counter, the N counter, and the internal mode control latches. The data format of a typical 24-bit data register is shown below. The control bits CTL [3:0] decode the register address. On the rising edge of LE, data stored in the shift register is loaded into one of the appropriate latches (selected by address bits). Data is shifted in MSB first. Note that it is best to program the N counter last, since doing so initializes the digital lock detector and Fastlock circuitry. Note that initialize means it resets the counters, but it does NOT program values into these registers. The exception is when 22-bit is not being used. In this case, it is not necessary to program the R7 register. MSB LSB DATA [21:0] CTL [3:0] 23 4 3 2 1 0 2.0.1 Register Location Truth Table The control bits CTL [3:0] decode the internal register address. The table below shows how the control bits are mapped to the target control register. C3 C2 C1 C0 DATA Location x x x 0 R0 0 0 1 1 R1 0 1 0 1 R2 0 1 1 1 R3 1 0 0 1 R4 1 0 1 1 R5 1 1 0 1 R6 1 1 1 1 R7 necessary for the PLL to achieve lock. The last 5 registers are for features that optimize spur, phase noise, and lock time performance. The next page shows these registers. 2.0.2 Control Register Content Map Because the LMX2485 registers are complicated, they are organized into two groups, basic and advanced. The first four registers are basic registers that contain critical information Quick Start Register Map Although it is highly recommended that the user eventually take advantage of all the modes of the LMX2485, the quick start register map is shown in order for the user to get the part up and running quickly using only those bits critical for basic functionality. The following default conditions for this programming state are a third order delta-sigma modulator in 12-bit mode with no dithering and no Fastlock. RE 23 GIS TE R 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 DATA[19:0] ( Except for the RF_N Register, which is [22:0] ) R0 RF_N[10:0] R1 RF RF _P _P D R4 RF_R[5:0] C3 C2 0 www.national.com 1 RF_CPG[3:0] 0 0 0 0 1 0 C1 C0 0 RF_FD[11:0] IF_N[18:0] 0001 0 2 RF_FN[11:0] R2 IF_ PD R3 3 IF_R[11:0] 0 1 1 0 0 0 24 1 1 1 0 0 0 0 0 0 1 1 0 1 0 1 0 1 1 1 1 0 0 1 RE 23 GIS TE R 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 DATA[19:0] ( Except for the RF_N Register, which is [22:0] ) R0 RF_N[10:0] R1 RF _P D R2 IF_ PD R3 R4 RF _P 1 RF_CPG[3:0] 0 R5 0 IF_R[11:0] DITH [1:0] FM [1:0] 0 OS OS IF_ RF IF_ C C CP _ P _2X _O P CP UT P RF_FD[21:12] R6 CSR[1:0] R7 0 0 0 0 0 MUX [3:0] RF_FN[21:12] RF_CPF[3:0] 0 RF_TOC[13:0] 0 1 0 C3 C2 C1 C0 0 0 1 1 0 1 0 1 0 1 1 1 1 0 0 1 1 0 1 1 1 1 0 1 1 1 1 1 0 RF_FD[11:0] IF_N[18:0] 0 2 RF_FN[11:0] RF_R[5:0] ACCESS[3:0] AT PU 3 0 0 0 0 DIV 4 0 1 0 0 1 IF_ RF IF_ RF RS _R CP _C T ST T PT 2.1 R0 REGISTER Note that this register has only one control bit, so the N counter value to be changed with a single write statement to the PLL. RE 23 GIS TE R 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 DATA[22:0] R0 RF_N[10:0] 1 0 C0 RF_FN[11:0] 0 2.1.1 RF_FN[11:0] -- Fractional Numerator for RF PLL Refer to section 2.6.1 for a more detailed description of this control word. 2.1.2 RF_N[10:0] -- RF N Counter Value The RF N counter contains an 8/9/12/13 and a 16/17/20/21 prescaler. The N counter value can be calculated as follows: N = RF_P*RF_C + 4*RF_B + RF_A RF_C Max{RF_A, RF_B} , for N-2FM-1 ... N+2FM is a necessary condition. This rule is slightly modified in the case where the RF_B counter has an unused bit, where this extra bit is used by the delta-sigma modulator for the purposes of modulation. Consult the tables below for valid operating ranges for each prescaler. 25 www.national.com LMX2485/LMX2485E Complete Register Map The complete register map shows all the functionality of all registers, including the last five. LMX2485/LMX2485E Operation with the 8/9/12/13 Prescaler (RF_P=0) RF_N RF_N [10:0] RF_C [6:0] RF_B [1:0] <25 N values less than 25 are prohibited. 25-26 Possible only with a second order delta-sigma engine. 27-30 Possible only with a second or third order delta-sigma engine. RF_A [1:0] 31 0 0 0 0 0 1 1 0 1 1 ... . . . . . . . 0 . . . 1023 1 1 1 1 1 1 1 0 1 1 1 >1023 1 N values above 1023 are prohibited. Operation with the 16/17/20/21 Prescaler (RF_P=1) RF_N [10:0] RF_N RF_C [6:0] RF_B [1:0] <49 N values less than 49 are prohibited. 49-50 Possible only with a second order delta-sigma engine. 51-54 55 RF_A [1:0] Possible with a second or third order delta-sigma engine. 0 0 0 0 0 1 1 0 1 1 1 ... . . . . . . . . . . . 2039 1 1 1 1 1 1 1 0 1 1 1 2040-20 43 Possible with a second or third order delta-sigma engine. 2044-20 45 Possible only with a second order delta-sigma engine. >2045 N values greater than 2045 are prohibited. www.national.com 26 REGISTER 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 DATA[19:0] R1 RF_PD RF_P RF_R[5:0] 3 2 1 0 C3 C2 C1 C0 0 0 1 1 RF_FD[11:0] 2.2.1 RF_FD[11:0] -- RF PLL Fractional Denominator The function of these bits are described in section 2.6.2. 2.2.2 RF_R [5:0] -- RF R Divider Value The RF R Counter value is determined by this control word. Note that this counter does allow values down to one. R Value RF_R[5:0] 1 0 0 0 0 0 ... . . . . . 1 . 63 1 1 1 1 1 1 2.2.3 RF_P -- RF Prescaler bit The prescaler used is determined by this bit. RF_P Prescaler Maximum Frequency 0 8/9/12/13 2000 MHz 1 16/17/20/21 3000 MHz 2.2.4 RF_PD -- RF Power Down Control Bit When this bit is set to 0, the RF PLL operates normally. When it is set to one, the RF PLL is powered down and the RF Charge pump is set to a TRI-STATE mode. The CE pin and ATPU bit also control power down functions, and will override the RF_PD bit. The order of precedence is as follows. First, if the CE pin is LOW, then the PLL will be powered down. Provided this is not the case, the PLL will be powered up if the ATPU bit says to do so, regardless of the state of the RF_PD bit. After the CE pin and the ATPU bit are considered, then the RF_PD bit then takes control of the power down function for the RF PLL. 27 www.national.com LMX2485/LMX2485E 2.2 R1 REGISTER LMX2485/LMX2485E 2.3 R2 REGISTER REGISTER 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 DATA[19:0] R2 IF_PD IF_N[18:0] 3 2 1 0 C3 C2 C1 C0 0 1 0 1 2.3.1 IF_N[18:0] -- IF N Divider Value IF_N Counter Programming with the 8/9 Prescaler (IF_P=0) N Valu e IF_N[18:0] IF_B IF_A 23 N values less than or equal to 23 are prohibited because IF_B 3 is required. 24-5 5 Legal divide ratios in this range are: 24-27, 32-36, 40-45, 48-54 56 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 0 0 0 0 57 0 0 0 0 0 0 0 0 0 0 0 0 1 1 1 0 0 0 1 ... . . . . . . . . . . . . . . . . . . . 2621 43 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 1 1 1 Operation with the 16/17 Prescaler (IF_P=1) N Valu e IF_B IF_A 47 N values less than or equal to 47 are prohibited because IF_B 3 is required. 48-2 39 Legal divide ratios in this range are: 48-51, 64-68, 80-85, 96-102, 112-119, 128-136, 144-153, 160-170, 176-187, 192-204, 208-221, 224-238 240 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 0 0 0 0 241 0 0 0 0 0 0 0 0 0 0 0 1 1 1 1 0 0 0 1 ... . . . . . . . . . . . . . . . . . . . 5242 87 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2.3.4 IF_PD -- IF Power Down Bit When this bit is set to 0, the IF PLL operates normally. When it is set to 1, the IF PLL powers down and the output of the IF PLL charge pump is set to a TRI-STATE mode. If the ATPU bit is set and register R0 is written to, the IF_PD will be reset to 0 and the IF PLL will be powered up. If the CE pin is held low, the IF PLL will be powered down, overriding the IF_PD bit. www.national.com 28 REGISTER 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 DATA[19:0] R3 ACCESS[3:0] RF_CPG[3:0] IF_R[11:0] 3 2 1 0 C3 C2 C1 C0 0 1 1 1 2.4.1 IF_R[11:0] -- IF R Divider Value For the IF R divider, the R value is determined by the IF_R[11:0] bits in the R3 register. The minimum value for IF_R is 3. R Value IF_R[11:0] 3 0 0 0 0 0 0 0 0 0 0 1 1 ... . . . . . . . . . . . . 4095 1 1 1 1 1 1 1 1 1 1 1 1 2.4.2 RF_CPG -- RF PLL Charge Pump Gain This is used to control the magnitude of the RF PLL charge pump in steady state operation. RF_CPG Charge Pump State Typical RF Charge Pump Current at 3 Volts (A) 0 1X 95 1 2X 190 2 3X 285 3 4X 380 4 5X 475 5 6X 570 6 7X 665 7 8X 760 8 9X 855 9 10X 950 10 11X 1045 11 12X 1140 12 13X 1235 13 14X 1330 14 15X 1425 15 16X 1520 2.4.3 ACCESS -- Register Access word It is mandatory that the first 5 registers R0-R4 be programmed. The programming of registers R5-R7 is optional. The ACCESS [3:0] bits determine which additional registers need to be programmed. Any one of these registers can be individually programmed. According to the table below, when the state of a register is in default mode, all the bits in that register are forced to a default state and it is not necessary to program this register. When the register is programmable, it needs to be programmed through the MICROWIRE. Using this register access technique, the programming required is reduced up to 37%. ACCESS Bit Register Location Register Controlled ACCESS[0] R3[20] Must be set to 1 ACCESS[1] R3[21] R5 ACCESS[2] R3[22] R6 ACCESS[3] R3[23] R7 The default conditions the registers is shown below: 29 www.national.com LMX2485/LMX2485E 2.4 R3 REGISTER LMX2485/LMX2485E Re gis 23 ter 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 Data[19:0] 3 2 1 0 C3 C2 C1 C0 R4 Must be programmed manually. R4 R5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 1 1 R6 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1 0 1 R7 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 1 0 0 0 0 1 1 1 1 This corresponds to the following bit settings. Register R4 Bit Location Bit Name Bit Description Bit Value Bit State Disabled R4[23] ATPU Autopowerup 0 R4[17:16] DITH Dithering 2 Strong R4[15:14] FM Modulation Order 3 3rd Order R4[12] OSC_2X Oscillator Doubler 0 Disabled R4[11] OSC_OUT OSCout Pin Enable 0 Disabled R4[10] IF_CPP IF Charge Pump Polarity 1 Positive R4[9] RF_CPP RF Charge Pump Polarity 1 Positive R4[8] IF_P IF PLL Prescaler 1 16/17 R4[7:4] MUX Ftest/LD Output 0 Disabled R5[23:14] RF_FD[21:12] Extended Fractional Denominator 0 Disabled R5[13:4] RF_FN[21:12] Extended Fractional Numerator 0 Disabled R6[23:22] CSR Cycle Slip Reduction 0 Disabled R6[21:18] RF_CPF Fastlock Charge Pump Current 0 Disabled R6[17:4] RF_TOC RF Timeout Counter 0 Disabled R7[13] DIV4 Lock Detect Adjustment 0 Disabled (Fcomp 20 MHz) R7[7] IF_RST IF PLL Counter Reset 0 Disabled R7[6] RF_RST RF PLL Counter Reset 0 Disabled R5 R6 R7 www.national.com R7[5] IF_CPT IF PLL Tri-State 0 Disabled R7[4] RF_CPT RF PLL Tri-State 0 Disabled 30 This register controls the conditions for the RF PLL in Fastlock. REGISTER 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 DATA[19:0] R4 ATPU 0 1 0 0 0 DITH [1:0] FM [1:0] 0 OSC_ 2X 2 1 0 C3 C2 C1 C0 OSC_ IF_ RF_ IF_P OUT CPP CPP MUX [3:0] 1 0 0 1 2.5.1 MUX[3:0] Frequency Out & Lock Detect MUX These bits determine the output state of the Ftest/LD pin. MUX[3:0] Output Type Output Description 0 0 0 0 High Impedance Disabled 0 0 0 1 Push-Pull General purpose output, Logical "High" State 0 0 1 0 Push-Pull General purpose output, Logical "Low" State 0 0 1 1 Push-Pull RF & IF Digital Lock Detect 0 1 0 0 Push-Pull RF Digital Lock Detect 0 1 0 1 Push-Pull IF Digital Lock Detect 0 1 1 0 Open Drain RF & IF Analog Lock Detect 0 1 1 1 Open Drain RF Analog Lock Detect 1 0 0 0 Open Drain IF Analog Lock Detect 1 0 0 1 Push-Pull RF & IF Analog Lock Detect 1 0 1 0 Push-Pull RF Analog Lock Detect 1 0 1 1 Push-Pull IF Analog Lock Detect 1 1 0 0 Push-Pull IF R Divider divided by 2 1 1 0 1 Push-Pull IF N Divider divided by 2 1 1 1 0 Push-Pull RF R Divider divided by 2 1 1 1 1 Push-Pull RF N Divider divided by 2 2.5.2 IF_P -- IF Prescaler When this bit is set to 0, the 8/9 prescaler is used. Otherwise the 16/17 prescaler is used. IF_P IF Prescaler Maximum Frequency 0 8/9 800 MHz 1 16/17 800 MHz 31 www.national.com LMX2485/LMX2485E 2.5 R4 REGISTER LMX2485/LMX2485E 2.5.3 RF_CPP -- RF PLL Charge Pump Polarity RF_CPP RF Charge Pump Polarity 0 Negative 1 Positive (Default) 2.5.4 IF_CPP -- IF PLL Charge Pump Polarity For a positive phase detector polarity, which is normally the case, set this bit to 1. Otherwise set this bit for a negative phase detector polarity. IF_CPP IF Charge Pump Polarity 0 Negative 1 Positive 2.5.5 OSC_OUT Oscillator Output Buffer Enable OSC_OUT OSCout Pin 0 Disabled (High Impedance) 1 Buffered output of OSCin pin 2.5.6 OSC2X -- Oscillator Doubler Enable When this bit is set to 0, the oscillator doubler is disabled and the TCXO frequency presented to the IF R and RF R counters is equal to that of the input frequency of the OSCin pin. When this bit is set to 1, the TCXO frequency presented to the RF R counter is doubled. Phase noise added by the doubler is negligible. OSC2X Frequency Presented to RF R Counter Frequency Presented to IF R Counter 0 fOSCin fOSCin 1 2 x fOSCin 2.5.7 FM[1:0] -- Fractional Mode Determines the order of the delta-sigma modulator. Higher order delta-sigma modulators reduce the spur levels closer to the carrier by pushing this noise to higher frequency offsets from the carrier. In general, the order of the loop filter should be at least one greater than the order of the delta-sigma modulator in order to allow for sufficient roll-off. www.national.com FM Function 0 Fractional PLL mode with a 4th order delta-sigma modulator 1 Disable the delta-sigma modulator. Recommended for test use only. 2 Fractional PLL mode with a 2nd order delta-sigma modulator 3 Fractional PLL mode with a 3rd order delta-sigma modulator 32 Dithering is a technique used to spread out the spur energy. Enabling dithering can reduce the main fractional spurs, but can also give rise to a family of smaller spurs. Whether dithering helps or hurts is application specific. Enabling the dithering may also increase the phase noise. In most cases where the fractional numerator is zero, dithering usually degrades performance. Dithering tends to be most beneficial in applications where there is insufficient filtering of the spurs. This often occurs when the loop bandwidth is very wide or a higher order delta-sigma modulator is used. Dithering tends not to impact the main fractional spurs much, but has a much larger impact on the sub-fractional spurs. If it is decided that dithering will be used, best results will be obtained when the fractional denominator is at least 1000. DITH Dithering Mode Used 0 Disabled 1 Weak Dithering 2 Strong Dithering 3 Reserved 2.5.9 ATPU -- PLL Automatic Power Up When this bit is set to 1, both the RF and IF PLL power up when the R0 register is written to. When the R0 register is written to, the PD_RF and PD_IF bits are changed to 0 in the PLL registers. The exception to this case is when the CE pin is low. In this case, the ATPU function is disabled. 33 www.national.com LMX2485/LMX2485E 2.5.8 DITH[1:0] -- Dithering Control LMX2485/LMX2485E 2.6 R5 REGISTER REGISTER 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 DATA[19:0] R5 RF_FD[21:12] RF_FN[21:12] 3 2 1 0 C3 C2 C1 C0 1 0 1 1 2.6.1 Fractional Numerator Determination { RF_FN[21:12], RF_FN[11:0], ACCESS[1] } In the case that the ACCESS[1] bit is 0, then the part operates in 12-bit fractional mode, and the RF_FN2[21:12] bits become do not care bits. When the ACCESS[1] bit is set to 1, the part operates in 22-bit mode and the fractional numerator is expanded from 12 to 22-bits. Fra ctio nal Nu mer ator RF_FN[21:12] RF_FN[11:0] ( These bits only apply in 22- bit mode) 0 1 In 12- bit mode, these are do not care. In 22- bit mode, for N <4096, these bits should be all set to 0. ... 409 5 409 6 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 . . . . . . . . . . . . 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 ... . . . . . . . . . . . . . . . . . . . . . . 419 430 3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2.6.2 Fractional Denominator Determination { RF_FD[21:12], RF_FD[11:0], ACCESS[1]} In the case that the ACCESS[1] bit is 0, then the part is operates in the 12-bit fractional mode, and the RF_FD[21:12] bits become do not care bits. When the ACCESS[1] is set to 1, the part operates in 22-bit mode and the fractional denominator is expanded from 12 to 22-bits. Fra ctio nal Den omi nat or RF_FD[21:12] RF_FD[11:0] ( These bits only apply in 22- bit mode) 0 In 12- bit mode, these are do not care. In 22- bit mode, for N <4096, these bits should be all set to 0. 1 ... 409 5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 . . . . . . . . . . . . 1 1 1 1 1 1 1 1 1 1 1 1 409 6 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 ... . . . . . . . . . . . . . . . . . . . . . . 419 430 3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 www.national.com 34 REGISTER 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 DATA[19:0] R6 CSR[1:0] RF_CPF[3:0] RF_TOC[13:0] 3 2 1 0 C3 C2 C1 C0 1 1 0 1 2.7.1 RF_TOC -- RF Time Out Counter and Control for FLoutRF Pin The RF_TOC[13:0] word controls the operation of the RF Fastlock circuitry as well as the function of the FLoutRF output pin. When this word is set to a value between 0 and 3, the RF Fastlock circuitry is disabled and the FLoutRF pin operates as a general purpose CMOS TRI-STATE I/O. When RF_TOC is set to a value between 4 and 16383, the RF Fastlock mode is enabled and the FLoutRF pin is utilized as the RF Fastlock output pin. The value programmed into the RF_TOC[13:0] word represents two times the number of phase detector comparison cycles the RF synthesizer will spend in the Fastlock state. RF_TOC Fastlock Mode Fastlock Period [CP events] FLoutRF Pin Functionality 0 Disabled N/A High Impedance 1 Manual N/A Logic "0" State. Forces all Fastlock conditions 2 Disabled N/A Logic "0" State 3 Disabled N/A Logic "1" State 4 Enabled 4X2 = 8 Fastlock 5 Enabled 5X2 = 10 Fastlock ... Enabled ... Fastlock 16383 Enabled 16383X2 = 32766 Fastlock 2.7.2 RF_CPF -- RF PLL Fastlock Charge Pump Current Specify the charge pump current for the Fastlock operation mode for the RF PLL. Note that the Fastlock charge pump current, steady state current, and CSR control are all interrelated. RF_CPF RF Charge Pump State 0 1X 95 1 2X 190 2 3X 285 3 4X 380 4 5X 475 5 6X 570 6 7X 665 7 8X 760 8 9X 855 9 10X 950 10 11X 1045 11 12X 1140 12 13X 1235 13 14X 1330 14 15X 1425 15 16X 1520 35 Typical RF Charge Pump Current at 3 Volts (A) www.national.com LMX2485/LMX2485E 2.7 R6 REGISTER LMX2485/LMX2485E 2.7.3 CSR[1:0] -- RF Cycle Slip Reduction CSR controls the operation of the Cycle Slip Reduction Circuit. This circuit can be used to reduce the occurrence of phase detector cycle slips. Note that the Fastlock charge pump current, steady state current, and CSR control are all interrelated. Refer to section 1.8 for information on how to use this. www.national.com CSR CSR State Sample Rate Reduction Factor 0 Disabled 1 1 Enabled 1/2 2 Enabled 1/4 3 Enabled 1/16 36 RE GI ST ER 23 22 21 20 19 18 17 16 15 R7 0 0 0 0 0 0 0 0 0 14 13 12 11 10 9 8 0 1 0 0 1 7 6 5 4 Data[19:0] 0 DIV 4 3 2 1 0 C3 C2 C1 C0 IF_ RF IF_ RF RS _R CP _C T ST T PT 1 1 1 1 2.8.1 DIV4 -- RF Digital Lock Detect Divide By 4 Because the digital lock detect function is based on a phase error, it becomes more difficult to detect a locked condition for larger comparison frequencies. When this bit is enabled, it subdivides the RF PLL comparison frequency (it does not apply to the IF comparison frequency) presented to the digital lock detect circuitry by 4. This enables this circuitry to work at higher comparison frequencies. It is recommended that this bit be enabled whenever the comparison frequency exceeds 20 MHz and RF digital lock detect is being used. 2.8.2 IF_RST -- IF PLL Counter Reset When this bit is enabled, the IF PLL N and R counters are reset, and the charge pump is put in a Tri-State condition. This feature should be disabled for normal operation. Note that a counter reset is applied whenever the chip is powered up via software or CE pin. IF_RST IF PLL N and R Counters IF PLL Charge Pump 0 (Default) Normal Operation Normal Operation 1 Counter Reset Tri-State 2.8.3 RF_RST -- RF PLL Counter Reset When this bit is enabled, the RF PLL N and R counters are reset and the charge pump is put in a Tri-State condition. This feature should be disabled for normal operation. This feature should be disabled for normal operation. Note that a counter reset is applied whenever the chip is powered up via software or CE pin. RF_RST RF PLL N and R Counters RF PLL Charge Pump 0 (Default) Normal Operation Normal Operation 1 Counter Reset Tri-State 2.8.4 RF_TRI -- RF Charge Pump Tri-State When this bit is enabled, the RF PLL charge pump is put in a Tri-State condition, but the counters are not reset. This feature is typically disabled for normal operation. RF_TRI RF PLL N and R Counters RF PLL Charge Pump 0 (Default) Normal Operation Normal Operation 1 Normal Operation Tri-State 2.8.5 IF_TRI -- IF Charge Pump Tri-State When this bit is enabled, the IF PLL charge pump is put in a Tri-State condition, but the counters are not reset. This feature is typically disabled for normal operation. IF_TRI IF PLL N and R Counters IF PLL Charge Pump 0 (Default) Normal Operation Normal Operation 1 Normal Operation Tri-State 37 www.national.com LMX2485/LMX2485E 2.8 R7 REGISTER LMX2485/LMX2485E www.national.com 38 LMX2485/LMX2485E Physical Dimensions inches (millimeters) unless otherwise noted Plastic Quad LLP (SQ), Bottom View Order Number LMX2485SQ or LMX2485ESQ for 1000 Unit Reel Order Number LMX2485SQX or LMX2485ESQX for 4500 Unit Reel NS Package Number SQA24A 39 www.national.com LMX2485/LMX2485E High Performance Delta-Sigma Low Power Dual PLLatinum Frequency Synthesizer Notes For more National Semiconductor product information and proven design tools, visit the following Web sites at: Products Design Support Amplifiers www.national.com/amplifiers WEBENCH www.national.com/webench Audio www.national.com/audio Analog University www.national.com/AU Clock Conditioners www.national.com/timing App Notes www.national.com/appnotes Data Converters www.national.com/adc Distributors www.national.com/contacts Displays www.national.com/displays Green Compliance www.national.com/quality/green Ethernet www.national.com/ethernet Packaging www.national.com/packaging Interface www.national.com/interface Quality and Reliability www.national.com/quality LVDS www.national.com/lvds Reference Designs www.national.com/refdesigns Power Management www.national.com/power Feedback www.national.com/feedback Switching Regulators www.national.com/switchers LDOs www.national.com/ldo LED Lighting www.national.com/led PowerWise www.national.com/powerwise Serial Digital Interface (SDI) www.national.com/sdi Temperature Sensors www.national.com/tempsensors Wireless (PLL/VCO) www.national.com/wireless THE CONTENTS OF THIS DOCUMENT ARE PROVIDED IN CONNECTION WITH NATIONAL SEMICONDUCTOR CORPORATION ("NATIONAL") PRODUCTS. NATIONAL MAKES NO REPRESENTATIONS OR WARRANTIES WITH RESPECT TO THE ACCURACY OR COMPLETENESS OF THE CONTENTS OF THIS PUBLICATION AND RESERVES THE RIGHT TO MAKE CHANGES TO SPECIFICATIONS AND PRODUCT DESCRIPTIONS AT ANY TIME WITHOUT NOTICE. NO LICENSE, WHETHER EXPRESS, IMPLIED, ARISING BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. TESTING AND OTHER QUALITY CONTROLS ARE USED TO THE EXTENT NATIONAL DEEMS NECESSARY TO SUPPORT NATIONAL'S PRODUCT WARRANTY. EXCEPT WHERE MANDATED BY GOVERNMENT REQUIREMENTS, TESTING OF ALL PARAMETERS OF EACH PRODUCT IS NOT NECESSARILY PERFORMED. NATIONAL ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR BUYER PRODUCT DESIGN. BUYERS ARE RESPONSIBLE FOR THEIR PRODUCTS AND APPLICATIONS USING NATIONAL COMPONENTS. PRIOR TO USING OR DISTRIBUTING ANY PRODUCTS THAT INCLUDE NATIONAL COMPONENTS, BUYERS SHOULD PROVIDE ADEQUATE DESIGN, TESTING AND OPERATING SAFEGUARDS. EXCEPT AS PROVIDED IN NATIONAL'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, NATIONAL ASSUMES NO LIABILITY WHATSOEVER, AND NATIONAL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY RELATING TO THE SALE AND/OR USE OF NATIONAL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. LIFE SUPPORT POLICY NATIONAL'S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF NATIONAL SEMICONDUCTOR CORPORATION. As used herein: Life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. National Semiconductor and the National Semiconductor logo are registered trademarks of National Semiconductor Corporation. All other brand or product names may be trademarks or registered trademarks of their respective holders. Copyright(c) 2008 National Semiconductor Corporation For the most current product information visit us at www.national.com National Semiconductor Americas Technical Support Center Email: new.feedback@nsc.com Tel: 1-800-272-9959 www.national.com National Semiconductor Europe Technical Support Center Email: europe.support@nsc.com German Tel: +49 (0) 180 5010 771 English Tel: +44 (0) 870 850 4288 National Semiconductor Asia Pacific Technical Support Center Email: ap.support@nsc.com National Semiconductor Japan Technical Support Center Email: jpn.feedback@nsc.com IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI's terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI's standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications. TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Applications Audio www.ti.com/audio Communications and Telecom www.ti.com/communications Amplifiers amplifier.ti.com Computers and Peripherals www.ti.com/computers Data Converters dataconverter.ti.com Consumer Electronics www.ti.com/consumer-apps DLP(R) Products www.dlp.com Energy and Lighting www.ti.com/energy DSP dsp.ti.com Industrial www.ti.com/industrial Clocks and Timers www.ti.com/clocks Medical www.ti.com/medical Interface interface.ti.com Security www.ti.com/security Logic logic.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense Power Mgmt power.ti.com Transportation and Automotive www.ti.com/automotive Microcontrollers microcontroller.ti.com Video and Imaging RFID www.ti-rfid.com OMAP Mobile Processors www.ti.com/omap Wireless Connectivity www.ti.com/wirelessconnectivity TI E2E Community Home Page www.ti.com/video e2e.ti.com Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright (c) 2011, Texas Instruments Incorporated